R&S®RTE1000 Oscilloscope, Front viewR&S®RTE1000 Oscilloscope, Front viewR&S®RTE1000 Oscilloscope, Side viewR&S®RTE1000 Oscilloscope, Hero viewR&S®RTE1000 Oscilloscope, Application ImageThe R&S®RTE: Simply more scope

Key Facts

  • Bandwidth: 200 MHz to 2 GHz
  • Sample rate: 5 Gsample/s
  • Max. memory depth: 200 Msample
  • Vertical resolution: up to 16-bit
  • MSO: 16 digital channels, optional, retrofittable

Commençant à 6 310 CHF

  • Promo oscilloscopes
  • 10 years oscilloscopes
  • 3 year warranty extension
  • Multi domain icon

Truly uncompromized in performance

R&S®RTE1000 oscilloscopes offer a fully integrated multi-domain test solution with time, frequency, protocol and logic analysis functions. From embedded design development to power electronics analysis to general debugging, the R&S®RTE1000 handles everyday T&M challenges quickly, accurately and easily.

  • Up to 16-bit vertical resolution
  • 200 Msample deep memory to analyze long sequences
  • Quickly find signal faults with 1 million waveforms/s
  • Touch-optimized operation

Caractéristiques & avantages

More confidence in measurement results

  • Precise measurements due to very low inherent noise
  • Single-core A/D converter and up to 16-bit vertical resolution
  • Full measurement bandwidth, even at 500 μV/div
  • High time resolution combined with deep memory
  • Find rare signal faults quickly thanks to one million waveforms/s
  • Accurate triggering with a digital trigger system
 

See signal details with up to 16-bit vertical resolution in HD mode.
Open Lightbox

See signal details with up to 16-bit vertical resolution in HD mode.

More functions and faster results

  • Automatic measurements: 77 functions
  • QuickMeas: key measurement results at the push of a button
  • History function: look back in time
  • Mask test: settings in only seconds
  • FFT function: the easy way to analyze the signal spectrum
  • Search and navigation: focus on details

In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.
Open Lightbox

In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.

More fun to use

  • 10.4" high-resolution touchscreen
  • Fully customizable display
  • Fast access to important tools
  • Signal details at your fingertip
  • Documentation at the push of a button

You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.
Open Lightbox

You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.

Engineered for multi-domain challenges

  • Logic analysis: fast and precise testing of embedded designs
  • Serial protocols: easy triggering and decoding
  • Power analysis
  • Spectrum analysis
  • EMI debugging: testing during development
  • Integrated arbitrary waveform generator

The mixed signal option turns the R&S®RTE1000  oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.
Open Lightbox

The mixed signal option turns the R&S®RTE1000 oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.

Available models

Available models
Modèles
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Commençant à

R&S®RTE1022

Numéro de commande 1326.2000.22

Bandwidth
200 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1024

Numéro de commande 1326.2000.24

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1032

Numéro de commande 1326.2000.32

Bandwidth
350 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1034

Numéro de commande 1326.2000.34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1052

Numéro de commande 1326.2000.52

Bandwidth
500 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1054

Numéro de commande 1326.2000.54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1102

Numéro de commande 1326.2000.62

Bandwidth
1 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1104

Numéro de commande 1326.2000.64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1152

Numéro de commande 1326.2000.72

Bandwidth
1.5 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1154

Numéro de commande 1326.2000.74

Bandwidth
1.5 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1202

Numéro de commande 1326.2000.82

Bandwidth
2 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à

R&S®RTE1204

Numéro de commande 1326.2000.84

Bandwidth
2 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à
Specifications
Vertical system
Analog channelsR&S®RTE1022/R&S®RTE1032/ R&S®RTE1052/R&S®RTE1102/ R&S®RTE1152/R&S®RTE12022
Analog channelsR&S®RTE1024/R&S®RTE1034/ R&S®RTE1054/R&S®RTE1104/ R&S®RTE1154/R&S®RTE12044
Digital channels (opt.)16
Bandwidth (-3 dB)R&S®RTE1022/R&S®RTE1024
R&S®RTE1032/R&S®RTE1034
R&S®RTE1052/R&S®RTE1054
R&S®RTE1102/R&S®RTE1104
R&S®RTE1152/R&S®RTE1154
R&S®RTE1202/R&S®RTE1204
≥ 200 MHz
≥ 350 MHz
≥ 500 MHz
≥ 1 GHz
≥ 1.5 GHz
≥ 2 GHz
Rise timeR&S®RTE1022/R&S®RTE1024
R&S®RTE1032/R&S®RTE1034
R&S®RTE1052/R&S®RTE1054
R&S®RTE1102/R&S®RTE1104
R&S®RTE1152/R&S®RTE1154
R&S®RTE1202/R&S®RTE1204
< 1.75 ns
< 1 ns
< 700 ps
< 350 ps
< 233 ps
< 175 ps
Input impedance50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF  ± 1 pF (meas.)
Input sensitivitymax. bandwidth in all ranges50 Ω: 500 μV/div to 1 V/div
1 MΩ: 500 μV/div to 10 V/div
ADC resolution8 bit
System ENOB7 bit
Acquisition system
Realtime sampling ratemax. 5 Gsample/s on each channel
Acquisition memorystandard configuration,
per channel/1 channel active
R&S®RTE1000 2-channel model: 10/20 Msample
R&S®RTE1000 4-channel model: 10/40 Msample
max. upgrade (R&S®RTE-B102 option),
per channel/1 channel active
R&S®RTE1000 2-channel model: 50/100 Msample
R&S®RTE1000 4-channel model: 50/200 Msample
Max. acquisition rate> 1 000 000 waveforms/s
Decimation modesany combination of decimation mode and waveform arithmeticssample, peak detect, high resolution,
root mean square
Waveform arithmeticsoff, envelope, average
Horizontal system
Timebase range50 ps/div to 5000 s/div
Accuracy (after delivery/calibration)±2 ppm
Channel deskew±100 ns
Trigger system
Standard Trigger typesedge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video
Optional Trigger typesserial bus trigger
Trigger sensitivitydefinition of trigger hysteresiscan be set automatically or manually from 0 div to 5 div
Analysis and measurement functions
Automatic measurements 77 measurement functions
Cursor measurements2 cursor sets, each consisting of two horizontal and two vertical cursors
Waveform mathematics4 math waveforms;
mathematics, logical operations, comparison, FIR filter, FFT
Mask testing
Mask definitionadvanced (user-configurable, hardware based)
Logic analyzer (MSO) functionality
Digital input channels16
MSO Memory depth100 Mpts per channel
MSO Bandwidth400 MHz
MSO Sampling rate5 Gsample/s per channel
MSO Input impedance100 k || 4 pF
Parallel busesup to 4
General data
DimensionsW x H x D427 mm × 249 mm × 204 mm
(16.81 in × 9.8 in × 8.03 in)
Weightwithout options, nominal8,6 kg (18.96 lb)
Display10.4" LC TFT color touchscreen,
1024 × 728 pixel (XGA)
Interfaces1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output
Operating systemWindows

Available options

General
Produit
Désignation

Numéro de commande 1326.3570.02

Désignation

Mixed Signal Option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample per channel

Adds 16 digital channels to R&S®RTE1000 oscilloscopes.

Numéro de commande 1333.0750.02

Désignation

Digital Extension Port for R&S®RTE

Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTE-B1

Numéro de commande 1326.3012.02

Désignation

Arbitrary waveform generator

Add 2-channel 500 Msample/s waveform generator and 8-channel pattern generator

R&S®RTE-B10

Numéro de commande 1317.4978.02

Désignation

GPIB Interface

R&S®RTE-B18

Numéro de commande 1317.7002.02

Désignation

Replacement SSD, incl. firmware

SSD comes pre-installed with operating system and scope application

Memory upgrade
Produit
Désignation
R&S®RTE-B101

Numéro de commande 1326.1155.02

Désignation

Memory upgrade to 20 Msample

Memory upgrade to 20 Msample per channel (standard for R&S®RTE with SN ≥ 300000)

R&S®RTE-B102

Numéro de commande 1326.1161.02

Désignation

Memory upgrade to 50 Msample

Memory upgrade to 50 Msample per channel (standard for R&S®RTE with SN ≥ 300000)

Bandwidth upgrade
Produit
Désignation
R&S®RTE-B200

Numéro de commande 1326.1384.02

Désignation

Bandwidth upgrade of the R&S®RTE1022/4 to 350 MHz bandwidth, incl. calibration

R&S®RTE-B201

Numéro de commande 1326.1390.02

Désignation

Bandwidth upgrade of the R&S®RTE1022/4 to 500 MHz bandwidth, incl. calibration

R&S®RTE-B202

Numéro de commande 1326.1403.02

Désignation

Bandwidth upgrade of the R&S®RTE1022/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B203

Numéro de commande 1326.1410.02

Désignation

Bandwidth upgrade of the R&S®RTE1022/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B204

Numéro de commande 1326.1426.02

Désignation

Bandwidth upgrade of the R&S®RTE1022/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B205

Numéro de commande 1326.1432.02

Désignation

Bandwidth upgrade of the R&S®RTE1032/4 to 500 MHz bandwidth, incl. calibration

R&S®RTE-B206

Numéro de commande 1326.1449.02

Désignation

Bandwidth upgrade of the R&S®RTE1032/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B207

Numéro de commande 1326.1455.02

Désignation

Bandwidth upgrade of the R&S®RTE1032/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B208

Numéro de commande 1326.1461.02

Désignation

Bandwidth upgrade of the R&S®RTE1032/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B209

Numéro de commande 1326.1478.02

Désignation

Bandwidth upgrade of the R&S®RTE1052/4 to 1 GHz bandwidth, incl. calibration

R&S®RTE-B210

Numéro de commande 1326.1484.02

Désignation

Bandwidth upgrade of the R&S®RTE1052/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B211

Numéro de commande 1326.1490.02

Désignation

Bandwidth upgrade of the R&S®RTE1052/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B212

Numéro de commande 1326.1503.02

Désignation

Bandwidth upgrade of the R&S®RTE1102/4 to 1.5 GHz bandwidth, incl. calibration

R&S®RTE-B213

Numéro de commande 1326.1510.02

Désignation

Bandwidth upgrade of the R&S®RTE1102/4 to 2 GHz bandwidth, incl. calibration

R&S®RTE-B214

Numéro de commande 1326.1526.02

Désignation

Bandwidth upgrade of the R&S®RTE1152/4 to 2 GHz bandwidth, incl. calibration

Serial triggering and decoding
Produit
Désignation

Numéro de commande 1326.1178.02

Désignation

I²C/SPI triggering and decoding

Numéro de commande 1326.1184.02

Désignation

UART/RS-232 triggering and decoding

Numéro de commande 1326.1190.02

Désignation

CAN/LIN triggering and decoding

Numéro de commande 1326.1203.02

Désignation

FlexRay™ triggering and decoding

Numéro de commande 1326.1210.02

Désignation

I²S/LJ/RJ/TDM triggering and decoding

Numéro de commande 1326.1226.02

Désignation

MIL-1553 triggering and decoding

Numéro de commande 1326.1232.02

Désignation

ARINC 429 triggering and decoding

Numéro de commande 1326.1332.02

Désignation

Ethernet serial decoding

Numéro de commande 1326.1249.02

Désignation

CAN-FD triggering and decoding

Numéro de commande 1326.1603.02

Désignation

SENT triggering and decoding

Numéro de commande 1801.2852.02

Désignation

Bus analysis

Numéro de commande 1326.1326.02

Désignation

MANCHESTER/NRZ triggering and decoding

Numéro de commande 1326.1255.02

Désignation

MDIO triggering and decoding

Numéro de commande 1333.0615.02

Désignation

100BASE-T1 triggering and decoding

Numéro de commande 1326.1610.02

Désignation

USB 1.0/1.1/2.0/HSIC triggering and decoding

Numéro de commande 1326.3158.02

Désignation

USB-PD triggering and decoding

Numéro de commande 1326.2845.02

Désignation

SpaceWire triggering and decoding

Numéro de commande 1326.3193.02

Désignation

CXPI triggering and decoding

General analysis
Produit
Désignation

Numéro de commande 1326.1261.02

Désignation

High definition mode

Numéro de commande 1326.3006.02

Désignation

Spectrum analysis

Numéro de commande 1326.1278.02

Désignation

Power analysis

Windows upgrade
Produit
Désignation
R&S®RTE-U2

Numéro de commande 1802.9296.02

Désignation

Upgrade to Windows 10 (includes new PC and Windows 10 license)

R&S®RTE-U2A

Numéro de commande 1802.9338.02

Désignation

Upgrade to Windows 10 (includes new PC, new SSD and Windows 10 license)

Accessories
Produit
Désignation
R&S®RTO-Z1

Numéro de commande 1333.0096.02

Désignation

Front Cover

Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope

R&S®RTO-Z3

Numéro de commande 1304.9118.02

Désignation

Soft Case

Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories

R&S®RTO-Z4

Numéro de commande 1317.7025.02

Désignation

Transit case

Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport

Numéro de commande 1317.7031.02

Désignation

Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes

R&S®ZZA-RTO

Numéro de commande 1304.8286.00

Désignation

19" Rackmount Adapter

For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 19" rack with 6U heigth

R&S®RT-Z2T

Numéro de commande 1338.0007.02

Désignation

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

Passive probes
Produit
Désignation

Numéro de commande 1409.7550.00

Désignation

Passive probe, 500 MHz, 10:1

Active single-ended probes
Produit
Désignation

Numéro de commande 1418.7007.02

Désignation

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4080.02

Désignation

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.3502.02

Désignation

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.4309.02

Désignation

Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Produit
Désignation

Numéro de commande 1410.4715.02

Désignation

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4609.02

Désignation

Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4409.02

Désignation

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Modular probe system
Produit
Désignation

Numéro de commande 1800.4700.02

Désignation

Modular probe amplifier module, 1.5 GHz

Numéro de commande 1419.3005.02

Désignation

Modular probe amplifier module, 3 GHz

R&S®RT-ZMA10

Numéro de commande 1419.4301.02

Désignation

Solder-in probe tip cable for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA10-6

Numéro de commande 1801.4349.02

Désignation

Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system

>16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA11

Numéro de commande 1419.4318.02

Désignation

Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA12

Numéro de commande 1419.4324.02

Désignation

Square-pin probe tip module for R&S®RT-ZM modular probe system

> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA15

Numéro de commande 1419.4224.02

Désignation

Quick connect probe tip module for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA30

Numéro de commande 1419.4353.02

Désignation

Browser module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, DM

R&S®RT-ZMA40

Numéro de commande 1419.4201.02

Désignation

SMA module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA50

Numéro de commande 1419.4218.02

Désignation

Temperature kit for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

Power rail probes
Produit
Désignation

Numéro de commande 1800.5006.02

Désignation

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

Multi-channel power probes
Produit
Désignation

Numéro de commande 1326.0259.02

Désignation

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs

Numéro de commande 1326.0259.04

Désignation

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs

High voltage probes
Produit
Désignation

Numéro de commande 1333.0873.02

Désignation

250 MHz passive high voltage probe

Numéro de commande 1409.7720.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1409.7737.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1422.0703.02

Désignation

100 MHZ high voltage differential probe

Numéro de commande 1333.0821.02

Désignation

Active differential probe, 200 MHz, BNC interface

Numéro de commande 1333.0838.02

Désignation

Active differential probe, 800 GHz, BNC interface

Numéro de commande 1800.2107.02

Désignation

100 MHz High voltage differential probe

Numéro de commande 1800.2207.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2007.02

Désignation

100 MHz High voltage differential probe

Numéro de commande 1337.9700.02

Désignation

25 MHz High voltage differential probe

Numéro de commande 1337.9800.02

Désignation

25 MHz High voltage differential probe

Current probes
Produit
Désignation

Numéro de commande 1333.0850.02

Désignation

AC/DC 20 kHz current probe

Numéro de commande 1333.0844.02

Désignation

100 kHz current probe

Numéro de commande 1409.8204.02

Désignation

2 MHZ current probe

Numéro de commande 1409.7750K02

Désignation

10 MHZ current probe

Numéro de commande 1409.8210.02

Désignation

10 MHZ Current probe

Numéro de commande 1409.8227.02

Désignation

50 MHZ Current probe

Numéro de commande 1409.7766K02

Désignation

100 MHZ current probe

Numéro de commande 1409.8233.02

Désignation

100 MHZ current probe

Numéro de commande 1409.7772K02

Désignation

120 MHz current probe

Numéro de commande 1801.4932.02

Désignation

120 MHz current probe

EMC near-field probes
Produit
Désignation

Numéro de commande 1147.2736.02

Désignation

E and H near-field probe set

Application bundles
Produit
Désignation
R&S®RTE-TDBNDL

Numéro de commande 1326.4190.02

Désignation

Trigger and decode bundle option

Decode more than 28 serial protocols with the R&S®RTE trigger and decode software bundle. T&D bundle includes I2C/SPI, UART/RS232, CAN/LIN, FlexRay, I2S, MIL, ARINC, Ethernet, CAN-FD, SENT, Custom, MDIO, USB2.0, USB-PD, SpaceWire, CXPI

RTE1000 - Media center

Intégrité de puissance - capture 1

La qualité de l'alimentation électrique est un facteur clé en termes de fonctionnalité et de performance des circuits électroniques sensibles.

mai 19, 2018

Débogage R&S®Multi-domain de dispositifs IoT embarqués

Cette vidéo présente les capacités de tests multidomaines des oscilloscopes Rohde & Schwarz.

mars 09, 2018

Intégrité de puissance - capture 2

5 conseils pour réaliser des mesures plus précises

mars 07, 2018

R&S®RTE - Tutoriel : Zoom

Introduction de base à l'utilisation de la fonctionnalité zoom.

févr. 15, 2018

R&S®RTE - Tutoriel : Barre d'outils

Introduction de base à l'utilisation des fonctionnalités de la barre d'outils.

févr. 15, 2018

R&S®RTE - Tutoriel : Réseau intelligent

Introduction de base à l'utilisation de la fonctionnalité réseau intelligent.

févr. 15, 2018

R&S®RTE - Tutoriel : Test de masque

Introduction de base à l'utilisation de la fonctionnalité test de masque.

févr. 15, 2018

R&S®RTE - Tutoriel : Histogramme

Procédure de base pour l'utilisation de la fonctionnalité histogramme.

févr. 15, 2018

RTE Application videos - Media center

Analyse approfondie de votre interface RS-232

Analyse approfondie des interfaces RS-232 trame par trame en utilisant le tableau de décodage du R&S®RTO et la fenêtre zoom.

févr. 13, 2020

Débogage des interfaces RS-232, RS-485 ou UART

Laissez votre oscilloscope décoder vos interfaces UART / RS-232 / RS-485 pour vous ! Ainsi, vous pouvez comprendre les données et corréler les contenus des données avec le signal électrique.

févr. 13, 2020

Décodage I²C avec le matériel de déclenchement du RTO

Comment identifier et suivre des erreurs dans les interfaces I²C en utilisant le matériel de déclenchement associé au mode historique.

févr. 13, 2020

Possibilités proposées par le protocole de décodage I²C

Plongez dans votre protocole afin de vérifier d'éventuels problèmes avec votre interface I²C.

févr. 13, 2020

La bonne configuration pour décoder un bus I²C avec un oscilloscope

Découvrez comment décoder facilement un bus I²C avec la bonne configuration, comme illustré sur un R&S®RTO.

févr. 13, 2020

Intégrité de puissance - capture 1

La qualité de l'alimentation électrique est un facteur clé en termes de fonctionnalité et de performance des circuits électroniques sensibles.

mai 19, 2018

Débogage R&S®Multi-domain de dispositifs IoT embarqués

Cette vidéo présente les capacités de tests multidomaines des oscilloscopes Rohde & Schwarz.

mars 09, 2018

Déclenchement et décodage SpaceWire

mars 08, 2018

Ce qui pourrait également vous intéresser

10 ans d’innovation dans les oscilloscopes

Les 10 ans de Rohde & Schwarz en termes d'innovation dans le domaine des oscilloscopes

Plus d'information

Promotion sur les oscilloscopes

Promotion sur les oscilloscopes

Choisissez la bonne promotion R&S en fonction de vos besoins individuels et faîtes d'économies

Plus d'information

Webinaires Rohde & Schwarz

Centre de webinaires dédié aux oscilloscopes pour les applications d'électronique de puissance et de conceptions numériques

Plus d'information

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Je souhaite recevoir des informations de Rohde & Schwarz via

Marketing de permission

Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.