EMC analysis of discontinuous disturbances (click rate)

Most modern electronically controlled appliances still switch their loads – such as heating elements and motors – with mechanical relays. Each relay opening or closing generates a short, broadband click that can exceed the disturbance voltage limits of a quasi-peak (QP) detector. Because these transients are intermittent, they are evaluated separately as discontinuous disturbances (clicks) in line with CISPR 14-1/EN 55014-1.

Setup for line conducted measurements
Setup for line conducted measurements

For a dedicated click rate measurement setup, the R&S®EPL EMI test receiver in combination with an LISN such as the R&S®ENV216 offers the best price with comprehensive functionality.

Your task

Most modern electronically controlled appliances still switch their loads – such as heating elements and motors – with mechanical relays. Each relay opening or closing generates a short, broadband click that can exceed the disturbance voltage limits of a quasi-peak (QP) detector. Because these transients are intermittent, they are evaluated separately as discontinuous disturbances (clicks) in line with CISPR 14-1/EN 55014-1.

Rohde & Schwarz solution

The R&S®EPL1-K59/R&S®ESW-K59 click rate analyzer option with an R&S®EPL or R&S®ESW EMI test receiver provides a complete solution for all applicable requirements.

The key features of this solution are:

  • Compliance with CISPR 14-1:2016/EN 55014-1:2017 and CISPR 14-1:2020/EN 55014-1:2021 (alternative frequency settings for DENAN law supported)
  • Four-channel standard compliant click rate analysis (150 kHz, 500 kHz, 1.4 MHz and 30 MHz in parallel)
  • Accredited verification in line with CISPR 16-1-1 available
  • Time resolution ≤ 500 μs for precise measurement of the click duration using the peak detector and determination of compliance using the quasi-peak detector
  • Recording the number of clicks and calculation of click rate
  • Allowance of all exceptions specified by standards
  • Remote control of R&S®ENV216, R&S®ENV432, R&S®ENV4200, R&S®ESH2-Z5 and R&S®ESH3-Z5 1) line impedance stabilization networks (LISN)
  • Generation of detailed test report
  • Electronic archiving of measured data over a measuring time of up to four hours
  • Possibility of post-modification of measurement settings

1) R&S®ESH2-Z5 and R&S®ESH3-Z5 are discontinued.

Application

The R&S®EPL1-K59/R&S®ESW-K59 four-channel click rate analyzer option provides everything required to measure CISPR 14-1 compliant discontinuous disturbance measurements (click measurements). These measurements can be easily configured and run for a defined period of time or until a specific number of clicks is detected.

R&S®EPL EMI test receiver with click rate analyzer

  • Straightforward configuration of all presettings
  • Fully automated test run for EUT programs lasting up to four hours

Detailed display of measured clicks

  • Complete timeline, zoom area and actual traces of all four channels or only those of interest are displayed in one window
  • Relevant values can be measured and presented
  • Postprocessing possible over the entire measured data

Overall result view

  • Final result view with calculated click rate per channel and test verdict
  • Disclosure of used exemptions
  • Recalculation with modified presetting possible

Flow chart decision view

Visualization of decisions regarding the applied standard in a flow chart.

Summary

For both conformance test houses and appliance development, the R&S®EPL and R&S®ESW EMI test receivers with click rate analyzer option provide a reliable solution that covers all applicable requirements in the context of discontinuous disturbance measurements (click rate analysis).

Informationen anfordern

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.
For service/support requests, please go here to log in or register.

Marketing-Einverständniserklärung

Ihre Anfrage wurde erfolgreich versendet. Wir nehmen in Kürze Kontakt mit Ihnen auf.
An error is occurred, please try it again later.