R&S®NRPM OTA power measurement solution

R&S®NRPM OTA power measurement solution
Abrir Lightbox
R&S®OTA power measurement solution, RF shield box
Abrir Lightbox
R&S®NRPM-A90 single-polarized antenna module
Abrir Lightbox
R&S®NRPM-A90D dual-polarized antenna module
Abrir Lightbox
R&S®NRPM3 3-channel sensor module
Abrir Lightbox
R&S®NRPM-Z3 interface module
Abrir Lightbox
R&S®NRPM-ZD3 filtered feedthrough module
Abrir Lightbox
R&S®NRPM OTA power measurement solution R&S®OTA power measurement solution, RF shield box R&S®NRPM-A90 single-polarized antenna module R&S®NRPM-A90D dual-polarized antenna module R&S®NRPM3 3-channel sensor module R&S®NRPM-Z3 interface module R&S®NRPM-ZD3 filtered feedthrough module

Key facts

  • Frequency range from 18 GHz to 90 GHz
  • Ideal for beamforming tests
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements
  • 3 years warranty extension

Designed for extremly accurate Over-the-Air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.

Features & benefits

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain and antenna pattern and from mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, the antenna pattern and the diode detector are calibrated together. Complicated system calibration by the user is not necessary.

Open Lightbox

OTA power measurement system

Low-reflection antenna module

Low radar cross section to avoid disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideally suited for use in a screened environment, due to the virtual absence of reflections.

Open Lightbox

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

R&S®NRPM OTA power measurement solution therefore uses a highly sensitive diode detector which is integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules are therefore able to measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be determined precisely.

Open Lightbox

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the receiver of the DUT, it is necessary to know exactly the power at the DUT, transmitted OTA to the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT to calibrate the transmit power of the signal generator. The calibration is done with an R&S®NRPM-A90/A90D antenna module, which is then replaced by the DUT. The receive power of the DUT is then exactly known.

Open Lightbox

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power of all antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane functions properly. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged in at least two horizontal planes.

Open Lightbox

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
  relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty (measurement distance 1m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
  relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Product
Description
R&S®NRPM- A90 single polarized antenna module

Order number 1426.7760.02

Description
Single-polarized antenna module
Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power measurements.
R&S®NRPM-A90D dual-polarized antenna module
R&S®NRPM-A90D

Order number 1426.7777.02

Description
Dual-polarized antenna module
Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.
Sensor modules
Product
Description
NRPM3-Three-Channel_Sensor_Module_img1.jpg

Order number 1425.8563.02

Description
Three-channel sensor module
Interface for shielded RF test box
Product
Description
R&S NRPM-ZD3 filtered cable feedthrough
R&S®NRPM-ZD3

Order number 1425.8786.02

Description
Filtered cable feedthrough
R&S®NRPM-ZKD3 interface cable
R&S®NRPM-ZKD3

Order number 1425.8770.02

Description
Interface cable
Interface for benchtop application
Product
Description
R&S®NRPM-Z3 interface module
R&S®NRPM-Z3

Order number 1426.7602.02

Description
Interface module
The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.
General accessories
Product
Description
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.02

Description
USB interface cable, length: 0.75 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.03

Description
USB interface cable, length: 1.5 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.04

Description
USB interface cable, length: 3 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.05

Description
USB interface cable, length: 5 m
R&S®NRP-ZK6

Order number 1419.0664.02

Description
6-pole interface cable, length: 1.5 m
R&S®NRP-ZK6

Order number 1419.0664.03

Description
6-pole interface cable, length: 3 m
R&S®NRP-ZK6

Order number 1419.0664.04

Description
6-pole interface cable, length: 5 m
NRP-Z5_Sensor_Hub_front.jpg

Order number 1146.7740.02

Description
USB sensor hub
R&S®NRPM-ZKT

Order number 1425.8857.02

Description
Trigger cable

Related videos

Uso del R&S®NRPM

may. 18, 2020

Nociones básicas sobre las medidas de potencia OTA

may. 18, 2020

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Deseo recibir información de Rohde & Schwarz por

Permiso de marketing

¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para test y medida, seguridad en las comunicaciones, monitorización y medidas de redes, broadcast y multimedia así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.