R&S®MXO 4 Oscilloscope

Next generation oscilloscope for accelerated insight

R&S®MXO 4 Oscilloscope
Abrir Lightbox
R&S®MXO 4 Oscilloscope
Abrir Lightbox
R&S®MXO 4 Oscilloscope
Abrir Lightbox
R&S®MXO 4 Oscilloscope
Abrir Lightbox
R&S®MXO 4 Oscilloscope
Abrir Lightbox
R&S®MXO4 oscilloscope, front view R&S®MXO4 oscilloscope, application image R&S®MXO4 oscilloscope, application image R&S®MXO4 oscilloscope R&S®MXO 4 oscilloscope

Key Facts

  • Bandwidth: 200 MHz - 1.5 GHz
  • World’s first oscilloscope with an update rate > 4.5 million waveforms per second
  • Industry-leading system architecture: 18-bit vertical resolution/12-bit ADC
  • Deepest in class standard memory: 400 Mpoints
  • Industry leading spectrum acquisition rate of 45,000 FFT/s

A partir de 8.280 EUR

NEXT GENERATION TECHNOLOGY

The R&S®MXO 4 series is the first of a new generation of oscilloscopes that excels in both performance and value. The instruments deliver a once-in-a-decade engineering breakthrough for accelerated insight.

They have the world’s fastest real-time update rate of 4.5 million waveforms/s, meaning engineers can see more infrequent events than with any other instrument. The 12-bit ADC in the R&S®MXO 4 series has 16 times the resolution of traditional 8-bit oscilloscopes at all sample rates for more precise measurements without any compromises. A standard 400 Mpoint acquisition memory on all four channels and an optional 800 Mpoint interleaved memory provide the instrument with up to 100 times the standard memory of comparable instruments.

A class above similar oscilloscopes, R&S®MXO 4 series oscilloscopes sport an impressive 13.3" Full HD capacitive touchscreen and an intuitive user interface with a learning curve of less than 15 minutes.
 

Features & benefits

Find signal anomalies quickly

... with unparalleled update rate
 

  • > 4.5 million waveforms/s.
  • Up to 90 % real-time signal capture
  • Fast performance with active automatic measurements, FFT or cursor measurements
  • Quickly and reliably detect sporadic signal faults

Typical update rate (left) vs. 4.5 million waveforms/s (right)
Abrir Lightbox

Typical update rate (left) vs. 4.5 million waveforms/s (right)

See your signals accurately

… with lowest measurement noise and highest vertical resolution
 

  • 12 bit ADC vertical resolution at all sample rates without compromise
  • 18 bit architecture with HD mode
  • Vertical scaling down to 500 μV/div at full bandwidth
  • Industry’s highest available offset range of ±5 V at 500 μV/div

Typical vertical resolution (left) vs. 18 bit resolution HD Mode (right)
Abrir Lightbox

Typical vertical resolution (left) vs. 18 bit resolution HD Mode (right)

Capture more time

… with the deepest standard memory
 

  • Industry’s deepest memory of 400 Mpoints per channel
  • Standard segmented memory with 10,000 segments
  • Standard history mode with 10,000 acquisitions

Slow (left) vs. fast sample rate (right) with a long capture window
Abrir Lightbox

Slow (left) vs. fast sample rate (right) with a long capture window

Isolate events

… with high-precision digital trigger
 

  • Industry's most sensitive trigger: 1/10,000 vertical division
  • Best in class trigger jitter of just 1 ps
  • World’s fastest trigger rearm time of < 21 ns
  • Adjustable digital trigger filters
  • User-selectable hysteresis

Flexible triggering with digital trigger and HD mode
Abrir Lightbox

Flexible triggering with digital trigger and HD mode

Superior user experience

… with advanced usability designed for touch
 

  • Quick access to important tools and menu settings
  • R&S®SmartGrid for individual waveform layouts with drag and drop
  • Enhanced touch sensitivity when changing important parameter values
  • Find features and functions faster with the new search menu
  • Remote control access wherever and whenever you need it

15-Minute learning curve, superior touch, intuitive navigation
Abrir Lightbox

15-Minute learning curve, superior touch, intuitive navigation

Powerful spectrum analysis

... with dedicated RF controls

  • Obtain RF insights into your measurements with up to 45,000 FFTs/s
  • Pristine RF characteristics for great spectrum performance
  • Setup and analysis made easy with dedicated RF controls
  • Spectrum and time domain views, all time-correlated with independent controls
  • Automatic measurements such as peak lists, max./min. hold

Superior RF measurement capability
Abrir Lightbox

Superior RF measurement capability

Available models

Available models
Modelos
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
A partir de

R&S®MXO44-242

Order Number 1335.5050P02

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
400 Mpts per channel
Optional MSO
16 digital channels
A partir de
8.280 EUR

R&S®MXO44-243

Order Number 1335.5050P03

Bandwidth
350MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
400 Mpts per channel
Optional MSO
16 digital channels
A partir de
13.100 EUR

R&S®MXO44-245

Order Number 1335.5050P05

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
400 Mpts per channel
Optional MSO
16 digital channels
A partir de
16.900 EUR

R&S®MXO44-2410

Order Number 1335.5050P10

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
400 Mpts per channel
Optional MSO
16 digital channels
A partir de
21.000 EUR

R&S®MXO44-2415

Order Number 1335.5050P15

Bandwidth
1.5 GHz 
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
400 Mpts per channel
Optional MSO
16 digital channels
A partir de
24.200 EUR
Specifications
Vertical system
Analog channels 4
Digital channels (opt.) 16
Analog bandwidth (–3 dB) R&S®MXO 4 with (R&S®MXO 4 -B24x options)  200 MHz, 350 MHz, 500 MHz, 1 GHz, 1.5 GHz
Rise time R&S®MXO 4 (with R&S®MXO 4 -B24x options) 1.75 ns, 1 ns, 700 ps, 350 ps, 234 ps
Input impedance 50 Ω ± 1.5 %,
1 MΩ ± 1 % || 12 pF (meas.)
Input sensitivity at 50 Ω 0.5 mV/div to 1 V/div,
entire analog bandwidth supported for all input
sensitivities
at 1 MΩ 0.5 mV/div to 10 V/div,
entire analog bandwidth supported for all input sensitivities
Vertical resolution up to 18 bit with HD mode (high definition)
DC gain accuracy offset and position set to 0 V, after self-alignment
input sensitivity > 5 mV/div ±1 % full scale
input sensitivity ≤ 5 mV/div to ≥ 1 mV/div ±1.5 % full scale
input sensitivity < 1 mV/div ±2.5 % full scale
Acquisition system
Sampling rate analog channels (real time) max. 5 Gsample/s on 2 channels,
max. 2.5 Gsample/s on 4 channels
analog channels (interpolated) max. 5 Tsample/s
digital channels max. 5 Gsample/s on each channel
Acquisition memory standard 400 Mpoints with 4 active channel (single),
400 Mpoints with 2 active channel (run)
R&S®MXO4-B108 option 800 Mpoints with 2 active channel (single),
800 Mpoints with 1 active channel (run)
Max. acquisition rate > 4 500 000 waveforms/s
Acquisition modes sample, peak detect, average, envelope
Interpolation modes linear, sin(x)/x, sample & hold
Horizontal system
Timebase range Selectable between 200 ps/div and 10 000 s/div
 
Timebase accuracy after delivery/calibration, at +23 °C ±0.2 ppm
During calibration interval ±1 ppm
Channel-to-channel skew between analog channels < 100 ps (meas.)
between digital channels < 500 ps (meas.)
Trigger system
Standard trigger types Edge, glitch, width, runt, window, timeout, interval, slew rate, setup&hold, pattern, state
Advanced trigger modes A/B/R, serial bus, trigger in and out
Trigger sensitivity 0.0001 div, from DC to instrument bandwidth for all
vertical scales
Analysis and measurement
Automatic measurements 39
Cursor measurements 4
Waveform mathematics Up to 5 equations math on math (add, subtract, multiply, divide, absolute value,
square, square root, integrate, differentiate,
log10, loge, log2, reciprocal, invert, low pass,
high pass, rescale (a*x+b))
Logic analyzer (MSO) functionality
Digital input channels 16
MSO Bandwidth 400 MHz
MSO sampling rate 5 Gsamples/s per channel
General data
Dimensions W × H × D 414 mm × 279 mm × 162 mm
(16.3 in × 10.99 in × 6.38 in)
Weight without options, nominal 6.0 kg (13.23 lb)
Interfaces 1 x USB 3.0 super speed port
2 x USB 2.0 high speed port
2 x USB 3.1 gen1 ports
1 x USB 3.1 gen1, type B plug
1 Gbps LAN
HDMI for external monitor
External trigger, trigger output
Ref In, ref out
VESA mount
Display type 13.3" LC TFT color display with capacitive
touchscreen

Available options

General
Product
Descripción

Order Number 1335.4130.02

Descripción

Mixed signal option for R&S®MXO 4 series with 16 digital channels

Order Number 1335.4147.02

Descripción

Arbitrary waveform generator, 100 MHz, 2 analog channels

Memory upgrade
Product
Descripción
R&S®MXO4-B108

Order Number 1335.5772.02

Descripción

Memory upgrade to 800 Mpoints on 2 channels

Bandwidth upgrade
Product
Descripción
R&S®MXO4-B243

Order Number 1335.4276.02

Descripción

Upgrade of R&S®MXO 4 series oscilloscopes to 350 MHz bandwidth

R&S®MXO4-B245

Order Number 1335.4299.02

Descripción

Upgrade of R&S®MXO 4 series oscilloscopes to 500 MHz bandwidth

R&S®MXO4-B2410

Order Number 1335.4318.02

Descripción

Upgrade of R&S®MXO 4 series oscilloscopes to 1 GHz bandwidth

R&S®MXO4-B2415

Order Number 1335.4330.02

Descripción

Upgrade of R&S®MXO 4 series oscilloscopes to 1.5 GHz bandwidth

Serial triggering and decoding
Product
Descripción

Order Number 1335.5195.02

Descripción

Low speed serial triggering and decode (I2C/SPI/UART/RS-232/RS-422/RS-485)

Order Number 1335.5550.02

Descripción

Automotive serial triggering and decode (CAN/CAN-FD/CAN-XL/LIN)

R&S®MXO4-K550

Order Number 1335.5214.02

Descripción

SPMI serial decode

R&S®MXO4-K560

Order Number 1335.5943.02

Descripción

Automotive ethernet decode package: 10BASE-T1S

General analysis
Product
Descripción

Order Number 1335.5566.02

Descripción

Power analysis

Order Number 1335.5572.02

Descripción

Frequency response analysis (require MXO4-B6 as source)

General
Product
Descripción
R&S®MXO4-Z1

Order Number 1335.4360.02

Descripción

Front cover: protects the front of the R&S®MXO 4 oscilloscope
 

R&S®MXO4-Z3

Order Number 1335.5589.02

Descripción

Soft case stores the R&S®MXO 4 oscilloscope and accessories
 

R&S®MXO4-Z4

Order Number 1335.5595.02

Descripción

Transit case protects the R&S®MXO 4 oscilloscope and accessories during transport
 

R&S®ZZA-MXO4

Order Number 1335.5108.02

Descripción

Rackmount kit for R&S®MXO 4 oscilloscopes with 6 HU

Application bundles
Product
Descripción
R&S®MXO4-PK1

Order Number 1335.5237.02

Descripción

Application bundle, consists of the following options:
R&S®MXO4-K510, R&S®MXO4-K520, R&S®MXO4-K36, R&S®MXO4-B6

Passive probes
Product
Descripción

Order Number 1333.2401.02

Descripción

Passive probe, 500 MHz, 10:1

Order Number 1333.1370.02

Descripción

Passive probe, 38 MHz, 1:1

Order Number 1409.7550.00

Descripción

Passive probe, 500 MHz, 10:1

Order Number 1803.0005.02

Descripción

Passive probe, 700 MHz, 10:1

Active single-ended probes
Product
Descripción

Order Number 1418.7007.02

Descripción

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Order Number 1410.4080.02

Descripción

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Order Number 1333.0815.02

Descripción

Active single-ended probe, 1 GHz, BNC interface

Order Number 1410.3502.02

Descripción

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Product
Descripción

Order Number 1410.4715.02

Descripción

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Order Number 1410.4409.02

Descripción

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Product
Descripción

Order Number 1800.5006.02

Descripción

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Product
Descripción

Order Number 1333.0873.02

Descripción

250 MHz passive high voltage probe

Order Number 1409.7737.02

Descripción

400 MHz passive high voltage probe

Order Number 1409.7720.02

Descripción

400 MHz passive high voltage probe

Order Number 1800.2307.02

Descripción

200 MHz High voltage differential probe

Order Number 1800.2107.02

Descripción

100 MHz High voltage differential probe

Order Number 1800.2207.02

Descripción

200 MHz High voltage differential probe

Order Number 1800.2007.02

Descripción

100 MHz High voltage differential probe

Current probes
Product
Descripción

Order Number 1333.0850.02

Descripción

AC/DC 20 kHz current probe

Order Number 1409.8204.02

Descripción

2 MHZ current probe

Order Number 1409.7750K02

Descripción

10 MHZ current probe

Order Number 1409.8227.02

Descripción

50 MHZ Current probe

Order Number 1409.8210.02

Descripción

10 MHZ Current probe

Order Number 1409.7766K02

Descripción

100 MHZ current probe

Order Number 1409.8233.02

Descripción

100 MHZ current probe

Order Number 1409.7772K02

Descripción

120 MHz current probe

Order Number 1801.4932.02

Descripción

120 MHz current probe

Order Number 1333.0844.02

Descripción

100 kHz current probe

Modular probe system
Product
Descripción

Order Number 1800.4700.02

Descripción

Modular probe amplifier module, 1.5 GHz

Logic probes
Product
Descripción
R&S®RT-ZL04

Order Number 1333.0721.02

Descripción

400 MHz logic probe

EMC near field probes
Product
Descripción

Order Number 1147.2736.02

Descripción

E and H near-field probe set

Probe accessories
Product
Descripción

Order Number 1409.7789.02

Descripción

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

Order Number 1410.4744.02

Descripción

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.

Order Number 1326.3641.02

Descripción

3D probe positioner

3D positionier with central tensioning knob for easy clamping and positioning of probes (span width: 200 mm, clamping range: 15 mm)

Order Number 1800.0004.02

Descripción

Power deskew fixture

Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply

Vídeos relacionados

Generador de formas de onda arbitrarias

Los osciloscopios serie R&S®MXO 4 ofrecen un generador de formas de ondas arbitrarias de dos canales y 100 MHz totalmente integrado con toda una gama de formas de onda y tipos de modulación.

sept 27, 2022

Canales lógicos digitales

Todos los osciloscopios de la serie R&S®MXO 4 incorporan el hardware necesario en cada instrumento —todo lo que necesita el usuario son las sondas lógicas necesarias para comenzar utilizando los 16 canales digitales.

sept 27, 2022

Configuración de análisis de espectro independiente

La función de análisis de espectro del osciloscopio serie R&S®MXO 4 se configura introduciendo simplemente parámetros típicos, como la frecuencia central, el intervalo de frecuencia o el ancho de banda de resolución. La configuración de espectro es independiente de los ajustes del dominio temporal, pero están correlacionados en el tiempo.

sept 27, 2022

Memoria profunda

Con mayor memoria de adquisición, un osciloscopio es capaz de capturar por más tiempo, manteniendo la frecuencia de muestreo y el ancho de banda máximos. Con una memoria de adquisición estándar de 400 Mpts en los cuatro canales simultáneamente, el osciloscopio serie R&S®MXO 4 puede capturar más intervalos de tiempo y aplicar el zoom a detalles sin distorsión de plegado (aliasing).

sept 27, 2022

Funciones matemáticas rápidas

Con 5 canales matemáticos y más de 15 funciones diferentes, con el osciloscopio serie R&S®MXO 4 siempre es posible analizar en detalle formas de onda en directo o adquiridas

sept 27, 2022

Manejo remoto sencillo

Controle el osciloscopio serie R&S®MXO 4 de forma remota y visualice la pantalla en un PC o dispositivo móvil. En la operación remota se ve la misma interfaz de usuario que en el propio osciloscopio.

sept 27, 2022

Funcionamiento extremadamente silencioso

El ruido audible de los osciloscopios de la serie R&S®MXO 4 es extremadamente bajo, lo que facilita el trabajo enormemente.

sept 27, 2022

Medidas de integridad de potencia

Depurar y validar líneas de alimentación resulta mucho más eficiente con los osciloscopios de la serie R&S®MXO 4. Ofrecen numerosas ventajas como un amplio control de offset de CC para medir tensiones pequeñas, encontrar fuentes de interferencia acopladas con espectro rápido y muchas otras.

sept 27, 2022

El equipo del MXO4

¿Está preparado para el próXimo desafío? ¡Únase a nuestro equipo de eXpertos de R&S!

El MXO4 no es más que el primer producto de la próxima generación, y uno de los muchos retos que en R&S nos hemos propuesto superar.
Eche un vistazo a nuestras plazas vacantes: #makeideasreal

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.