PiMPro Tower passive intermodulation analyzer, Front viewPiMPro Tower passive intermodulation analyzer, Front viewPiMPro Tower passive intermodulation analyzer, Side viewPiMPro Tower passive intermodulation analyzer, Side viewPiMPro Tower passive intermodulation analyzer, Front viewPiMPro Tower passive intermodulation analyzer

Key Facts

  • One-port measurement of PIM, RL, PiMPoint (DTP) and DTF
  • Real-world 40 W × 2 PIM testing capability
  • Dual-band models for 1800/2100 and 1900/2100 bands
  • Easy to operate with look and feel of a smart phone
  • Lightest unit in the market (8.5 kg – PIM2600 model)

The challenge of keeping base stations PIM-free

In response to the increasing demand for higher data rates, network operators have to push their networks' spectral efficiency to the theoretical limit. Passive intermodulation (PIM) is one source of interference that affects spectral efficiency: it may cause a reduction in the data rate, dropped calls or even non-accessibility of the network.

The challenge for field service teams is to ensure efficient, fault-free installation of cell sites and quick troubleshooting if errors occur. The lightweight and rugged PiMPro Tower series with its easy-to-use interface provides full PIM testing capability, making it ideal to respond to today's challenges in the field.

Features & benefits

Site installation and maintenance

Sites free from PIM and defective components

Thanks to a collaboration with Communication Components Inc. (CCI), Rohde & Schwarz adds the PiMPro Tower PIM analyzer to its portfolio to provide network operators and test service companies with a comprehensive solution for base station installation and maintenance.

It ideally complements the fast  VSWR, cable loss, DTF and power measurements of the R&S®ZPH and R&S®ZVH cable and antenna analyzers and R&S®FSH handheld spectrum analyzer.

PIM and VSWR measurements
Abrir Lightbox

PIM and VSWR measurements

Efficient and fault-free installation of cell sites and quick troubleshooting if errors occur is easily done with the PiMPro Tower and R&S®Handhelds

Performance ready to go

40 W × 2 PIM testing capability, -135 dBm sensitivity - in a backpack

Each lightweight, compact unit is protected by a reinforced backpack case. Even in battery mode, the PiMPro Tower can deliver two 40 W output signals.  Its excellent measurement sensitivity of -135 dBm and its ability to reduce two-tone transmit signals to 24 dBm (100 mW) make the PIM analyzer the ideal instrument for measurements on base stations and DAS.

Lightweight and compact
Abrir Lightbox

Lightweight and compact

Lightest unit on the market presented as a comfortable backpack

PIM measurements

Why losing time calibrating?

Instantaneous PIM and RL, dynamic PIM vs time and frequency sweep measurements enable users to guarantee a PIM-free site and do not require any previous instrument calibration.

Pass/Marginal/Fail limits, output power, frequency and IM settings are easily configured. The PiMPro Tower’s unique return loss diagnostic feature at high transmit (TX) power quickly points out open cables.

Easy configuration, easy measurement
Abrir Lightbox

Easy configuration, easy measurement

All settings can be configured just by clicking on the field or icon.

One-port measurements

Why losing time toggling between different ports?

Users are able to perform PIM, return loss, PiMPont (distance-to-PIM) and distance-to-fault measurements on a single port and without requiring additional hardware.

Saving time in the field
Abrir Lightbox

Saving time in the field

All measurements can be done on a single port

DTF and PiMPoint (DTP) measurements

Simultaneously measured

Distance-to-fault and PiMPoint (distance-to-PIM) are simultaneously measured and displayed on the same graph.

The DTF and PiMPoints results guide users to the fault location.

DTF and PiMPoint (DTP) measurements
Abrir Lightbox

DTF and PiMPoint (DTP) measurements

All done from a single port, no need to connect to a separate measurement port.

Report generator

All tasks done, properly documented

Report data for all measurements can be stored in either HTML or PDF file format. Users can combine a limitless series of measurements with different sectors, feeders and color codes in one single PDF file.

Reports can be saved in the PiMPro Tower’s internal memory or to an external USB memory from the unit’s front panel.

Report generator
Abrir Lightbox

Report generator

All information is included: Site data, configuration settings, limits, measurement results, graphs and user entered comments.

Available models

Available models
Modelos
Band
Tx Frequency 1 (MHz)
Tx Frequency 2 (MHz)
Rx Frequency 1 (MHz)
Rx Frequency 2 (MHz)

PIM700

Order Number 3625.9570.02

Band
700
Tx Frequency 1 (MHz)
745.6 – 769.4
Tx Frequency 2 (MHz)
732.6 - 734.4
Rx Frequency 1 (MHz)
698 - 722
Rx Frequency 2 (MHz)
780 - 798

PIM700A

Order Number 3625.9587.02

Band
700 APT
Tx Frequency 1 (MHz)
758 – 776
Tx Frequency 2 (MHz)
788 - 807
Rx Frequency 1 (MHz)
703 - 748
Rx Frequency 2 (MHz)
825 - 845

PIM800

Order Number 3625.8380.02

Band
800
Tx Frequency 1 (MHz)
811 – 821
Tx Frequency 2 (MHz)
791 - 795
Rx Frequency 1 (MHz)
832 - 862
Rx Frequency 2 (MHz)
-

PIM850

Order Number 3625.9606.02

Band
850
Tx Frequency 1 (MHz)
864 – 871
Tx Frequency 2 (MHz)
881.6 - 894
Rx Frequency 1 (MHz)
824 - 849
Rx Frequency 2 (MHz)
-

PIM900

Order Number 3625.9612.02

Band
900
Tx Frequency 1 (MHz)
925 – 937.5
Tx Frequency 2 (MHz)
951.5 - 980
Rx Frequency 1 (MHz)
880 - 915
Rx Frequency 2 (MHz)
-

PIM1821

Order Number 3625.9641.02

Band
1800 / 2100
Tx Frequency 1 (MHz)
1805 – 1837
Tx Frequency 2 (MHz)
1855 - 1880
Rx Frequency 1 (MHz)
1710 - 1785
Rx Frequency 2 (MHz)
1920 - 1980

PIM1921

Order Number 3625.9658.02

Band
1900 / 2100
Tx Frequency 1 (MHz)
1965 – 1995; 2110 – 2155
Tx Frequency 2 (MHz)
1930 - 1945
Rx Frequency 1 (MHz)
1710 - 1755
Rx Frequency 2 (MHz)
1850 - 1910

PIM2600

Order Number 3625.9664.02

Band
2600
Tx Frequency 1 (MHz)
2620 – 2644
Tx Frequency 2 (MHz)
2690 - Fixed
Rx Frequency 1 (MHz)
2500 - 2570
Rx Frequency 2 (MHz)
-
Specifications
Transmitter
Frequency accuracy< 5 ppm
Power accuracy0.3 dB
Frequency step size200 kHz
Power resolution0.1 dB
Adjustable power range24 dBm to 46 dBm × 2 (250 mW to 40 W × 2)
Receiver
Residual intermodulation level-122 dBm (typ. -125 dBm)
Measurement sensitivity-135 dBm
Noise floor-136 dBm
Reverse power protection13 dBm (20 mW) continuous
Measurement mode
Measurement methodone port, reverse PIM
Real time PIM3rd and 5th PIM
PIM vs time3rd and 5th PIM
PIM location (PIMPoint)distance in meters or feet with VP Settings
RX interferencereceive only mode, noise floor measurement
Frequency Sweepfrequency response
System
Battery operation>3 hours
PowerAC and DC (AC: 90V to 256 V, 50HZ to 60 Hz)
Alarmsaudio and visual
Display size and type8.0” [203.2 mm] capacitive TFT (industrial grade)
Data ports3 x USB 2.0, 1 x Ethernet LAN port
Remote controlWiFi enabled (802.11)
Electrical characteristics
Battery power28 VDC
Battery capacity5.8 AH
Battery typeLi-polymer removable battery pack
Max. power consumption<340 W
Mechanical characteristics
Weight8.5 to 12.5 kg, depending on model
RF output connector7-16 DIN female
Dimensions (W × H × D)350 × 230 × 114 mm
Operating temperature range-10°C, –45°C, 95 % relative humidity
Storage Temperature range-30°C, –60°C, 85 % relative humidity
Accessories
Accessories includedDC adapter, operation manual

Available options

System packages
Product
Descripción
PIM700-SP

Order Number 3625.9758.02

Descripción

System package - PiMPro Tower 700

PIM700A-SP

Order Number 3625.9764.02

Descripción

System package - PiMPro Tower 700A

PIM800-SP

Order Number 3625.9787.02

Descripción

System package - PIMPro Tower 800

PIM850-SP

Order Number 3625.9806.02

Descripción

System package - PIMPro Tower 850

PIM900-SP

Order Number 3625.9812.02

Descripción

System package - PiMPro Tower 900

PIM1821-SP

Order Number 3625.9829.02

Descripción

System package - PiMPro Tower 1821

PIM1921-SP

Order Number 3625.9835.02

Descripción

System package - PiMPro Tower 1921

PIM2600-SP

Order Number 3625.9841.02

Descripción

System package - PiMPro Tower 2600

Basic packages
Product
Descripción
PIM700-BP

Order Number 3631.3041.02

Descripción

Basic package - PiMPro Tower 700

PIM700A-BP

Order Number 3631.3064.02

Descripción

Basic package - PiMPro Tower 700A

PIM800-BP

Order Number 3631.3106.02

Descripción

Basic package - PiMPro Tower 800

PIM850-BP

Order Number 3631.3112.02

Descripción

Basic package - PiMPro Tower 850

PIM900-BP

Order Number 3631.3129.02

Descripción

Basic package - PiMPro Tower 900

PIM1821-BP

Order Number 3631.3141.02

Descripción

Basic package - PiMPro Tower 1821

PIM1921-BP

Order Number 3631.3158.02

Descripción

Basic package - PiMPro Tower 1921

PIM2600-BP

Order Number 3631.3164.02

Descripción

Basic package - PiMPro Tower 2600

Software options
Product
Descripción
PIM-K11

Order Number 3626.0248.02

Descripción

GPS option

PIM-K21

Order Number 3626.0254.02

Descripción

DTF option

PIM-K31

Order Number 3626.0260.02

Descripción

Remote control option

Accessories
Product
Descripción
PIM-Z1

Order Number 3625.9929.02

Descripción

Universal accessory kit for PIM measurements

PIM-Z101

Order Number 3625.9941.02

Descripción

Low PIM load

PIM-Z102

Order Number 3625.9958.02

Descripción

PIM standard -80 dBm

PIM-Z110

Order Number 3625.9964.02

Descripción

RF cable 7/16 DIN-M to 7/16 DIN-F

PIM-Z111

Order Number 3625.9970.02

Descripción

RF cable 7/16 DIN-M to 7/16 DIN-M

PIM-Z120

Order Number 3625.9987.02

Descripción

7/16 DIN-M to 7/16 DIN-M adapter

PIM-Z121

Order Number 3626.0002.02

Descripción

7/16 DIN-F to 7/16 DIN-F adapter

PIM-Z124

Order Number 3631.2897.02

Descripción

7/16 DIN-M to 4.3/10-M adapter

PIM-Z125

Order Number 3631.2900.02

Descripción

7/16 DIN-M to 4.3/10-F adapter

PIM-Z130

Order Number 3626.0125.02

Descripción

Torque wrench

PIM-Z131

Order Number 3626.0148.02

Descripción

Adjustable wrench

PIM-Z132

Order Number 3626.0225.02

Descripción

32mm small fixed wrench

PIM-Z2

Order Number 3626.0160.02

Descripción

Transport case for PiMPro Tower series

PIM-Z3

Order Number 3626.0177.02

Descripción

Rechargeable Lithium battery for PiMPro Tower series

PIM-Z4

Order Number 3631.2916.02

Descripción

Spare Open - Short standard for PiMPro Tower series

PIM-Z5

Order Number 3631.2922.02

Descripción

Spare AC adapter for PiMPro Tower

PIM-Z6

Order Number 3631.2939.02

Descripción

Battery charger, for Lithium battery PiMPro Tower

PIM-Z7

Order Number 3631.2945.02

Descripción

Soft carrying case for accessories, PiMPro Tower series

Warranty extensions
Product
Descripción
PIM-EW1

Order Number 3626.0277.02

Descripción

Extended warranty for PiMPro Tower series

PIM-EW2

Order Number 3626.0283.02

Descripción

Extended warranty for PiMPro Tower series

PIM-EW4

Order Number 3626.0290.02

Descripción

Extended warranty for PiMPro Tower series

Serie PiMPro Tower

Gracias a nuestro acuerdo de colaboración con Communication Components Inc. (CCI), Rohde & Schwarz añade a su oferta un analizador de intermodulación pasiva (PIM), la serie PiMPro Tower, para proporcionar a las empresas de servicios de tests y operadores de redes una solución integral para la instalación y el mantenimiento de las estaciones base.

dic. 22, 2016

Competencia en medidas de intermodulación pasiva

¿Sospecha que hay problemas de intermodulación pasiva en su red? Nosotros le ayudamos
¿Sospecha que hay problemas de intermodulación pasiva en su red? Nosotros le ayudamos

El aumento de abonados y las velocidades de datos más altas se traducen en una presión constante en las redes que puede manifestarse en cualquier punto. Pero, ¿qué puede haber ocurrido si los técnicos reciben un aviso de bajo rendimiento pero no pueden detectar ningún componente defectuoso en la instalación de la estación transceptora base? La respuesta podría ser: intermodulación pasiva o, abreviado, PIM.

Más información

Medidas de PIM: resumen de prácticas recomendadas
Medidas de PIM: resumen de prácticas recomendadas

Cuando se trata de las medidas de PIM, los pasos necesarios para identificar la intermodulación pasiva (PIM) y encontrar su fuente son parecidos a los que se realizan para encontrar interferencias. Al fin y al cabo, la PIM es una fuente interna de interferencias y puede afectar considerablemente al rendimiento de una red.

Más información

Identificación de la intermodulación pasiva
Identificación de la intermodulación pasiva

La intermodulación pasiva no es un fenómeno nuevo. Es un problema que existe desde que se pusieron en funcionamiento las primeras redes comerciales. En el sistema GSM, cuando surgía un problema de PIM, los operadores de redes podían reasignar con facilidad las frecuencias. En 3G y 4G, sin embargo, la reasignación de frecuencias ya no es posible. Por lo tanto, es necesario acometer los problemas de intermodulación pasiva.

Más información

Redes heterogéneas/celdas pequeñas: instalación en emplazamientos interiores
Redes heterogéneas/celdas pequeñas: instalación en emplazamientos interiores

Una vez finalizada la planificación y el diseño de la red comienza la fase más crítica del despliegue de las celdas pequeñas: la instalación y la puesta en servicio definitiva en el emplazamiento interior. ¿Sabía que más del 50 % de los problemas de los abonados tienen su origen en el sistema de antenas?

Más información

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.