Frequency response analysis (Bode plot)

General analysis

Frequency Response Analysis (Bode plot) Control Loop Response
Open Lightbox
Frequency Response Analysis (Bode plot) Passive Components
Open Lightbox
Frequency Response Analysis (Bode plot) Power Supply Rejection Ratio
Open Lightbox
Frequency Response Analysis (Bode plot) Control Loop Response Frequency Response Analysis (Bode plot) Passive Components Frequency Response Analysis (Bode plot) Power Supply Rejection Ratio

Key facts

  • Bandwidth: 10 Hz to 25 MHz
  • Test modes: Fixed or custom amplitude profile
  • Points per decade: Logarithmic gain and linear phase
  • Analysis: Waveform cursors and tabular view of test results

Oscilloscope software

The R&S®RTx-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio. The frequency response analysis option uses the oscilloscope’s built-in waveform generator to create stimulus signals ranging from 10 Hz to 25 MHz. Measuring the ratio of the stimulus signal and the output signal of the DUT at each test frequency, the oscilloscope plots gain and phase logarithmically.

Caractéristiques & avantages

Amplitude profile

The R&S®RTx-K36 frequency response analysis (Bode plot) option allows users to profile the amplitude output level of the generator. This helps to suppress the noise behavior of the DUT when performing a control loop response or power supply rejection ratio and to improve signal-to-noise ratio (SNR). It is possible to define up to 16 steps.

Open Lightbox

Amplitude profile

Improve resolution and markers support

You can choose the points per decade to set up and modify the resolution of your plot. The oscilloscope supports up to 500 points per decade. Markers can be dragged to the desired position, directly on the plotted trace. A legend displays the corresponding coordinates of the markers. To determine the crossover frequency, set one marker to 0 dB and the second marker to –180° phase shift. Now you can easily determine the phase and gain margin.

Open Lightbox

Vary points per decade

Measurement table

Furthermore, you can view the results in a table. The table of measurement results details information about each measured point, consisting of frequency, gain and phase shift. In case you use cursors, for ease of use, the associated row of the result table is highlighted. For reporting, screenshots, table results or both can be quickly saved to a USB device.

Open Lightbox

Measurement table

Broad probe portfolio

Accurate control loop response or power supply rejection ratio characterization highly depends on choosing the right probes, since peak-to-peak amplitudes of both Vin and Vout can be very low at some test frequencies. These values would be buried in the oscilloscope’s noise floor or in the switching noise of the DUT itself. We recommend the low-noise R&S®RT-ZP1X 38 MHz bandwidth 1:1 passive probes. These reduce measurement noise and provide the best SNR.

Open Lightbox

R&S®RT-ZP1X 38 MHz 1:1 passive probe

Available models


  • Option Name

    R&S®RTA-K36

    Order number 1335.7975.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit
  • Option Name

    R&S®RTB-K36

    Order number 1335.8007.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit
  • Option Name

    R&S®RTM-K36

    Order number 1335.9178.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit

Gamme des oscilloscopes

Oscilloscopes

Des oscilloscopes qui répondent à vos besoins et cadrent avec votre budget ; de la valeur supérieure aux performances supérieures

Plus d'information

Options logicielles pour oscilloscopes

Augmentez les capacités de votre oscilloscope avec le logiciel d'application Rohde & Schwarz.

Plus d'information

Sondes pour oscilloscopes

Personnalisez votre oscilloscope avec les sondes et accessoires adaptés à votre application.

Plus d'information

Demander des informations

Vous avez des questions ou désirez des renseignements supplémentaires ? Veuillez simplement remplir ce formulaire et nous vous rappelons aussi tôt que possible.

Marketing de permission

Je souhaite recevoir des informations de Rohde & Schwarz via

Qu'est ce que cela signifie en détail ?

Je reconnais que les entités ROHDE & SCHWARZ GmbH & Co. KG et ROHDE & SCHWARZ ou toute autre société subsidiaire mentionnée au sein de ce site Internet, peuvent me contacter par le moyen de leur choix (email ou courrier) pour des raisons marketing et publicitaires (par exemple pour des informations sur des offres spéciales et des promotions) en relation avec, mais pas uniquement, des produits et des solutions dans les domaines du test et mesure, des communications sécurisées, de la surveillance et test des réseaux, des broadcasts et médias, ainsi que de cybersécurité.

Vos droits

Cette déclaration de consentement peut être révoquée à tout moment par l'envoi d'un courriel portant, dans son objet, la mention "Unsubscribe" (désinscription) à news@rohde-schwarz.com. En outre, chaque courriel envoyé contient un lien vers une fonction de désinscription de publicités ultérieures adressées par courrier électronique. La "Déclaration de confidentialité" expose plus en détail l'utilisation des données personnelles, ainsi que la procédure de révocation de consentement.

Merci.

Votre équipe Rohde & Schwarz

Une erreur est survenue. Veuillez essayer à nouveau ultérieurement.
Informations générales et conditions d'utilisation du site Web

Prix au détail conseillé par les fabricants. Le prix ne doit pas inclure la TVA. Les prix et offres s’adressent uniquement aux professionnels et non aux particuliers.