Key Facts

  • Bandwidth: 200 MHz to 1 GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 1 Gsample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

Commençant à 6 850 EUR

  • Promo oscilloscopes
  • 10 years oscilloscopes
  • 3-year warranty extension
  • EDN Hot 100 product

See more of your signal with the power of 10

Designed with top class signal integrity and responsive ultra-deep memory, the R&S®RTA4000 brings the power of 10 to a new level. The Rohde & Schwarz designed 10-bit ADC plus class-leading noise and memory depth provides sharp waveforms, more accurate measurements and confidence when facing unexpected measurement challenges.

Caractéristiques & avantages

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTA4000 features a customized Rohde & Schwarz designed 10-bit A/D converter and is a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

100 Msample standard and 200 Msample interleaved

The R&S®RTA4000 offers top class memory depth with 100 Msample per channel available and even 200 Msample in interleaved mode. This is ten times more than similar oscilloscopes in the same instrument class. The user can capture longer acquisition sequences even at high sampling rates for more analysis results, such as when analyzing transients of switched-mode power supplies.

100 Msample standard memory
Open Lightbox

100 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 200 Msample standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 1000 Msample with history function

The R&S®RTA-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment size optimally utilizes the 1000 Msample memory. In history mode, previous acquisitions in the maximum segmented memory depth of 1000 Msample are available for further analysis.

1000 Msample segmented memory
Open Lightbox

1000 Msample segmented memory

Capture the longest time periods with topclass 1000 Msample memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTA-B1 option turns every R&S®RTA4000 into an intuitive MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from the analog and digital components of an embedded design - synchronized and time correlated to each other. For example, the delay between A/D converter input and output can conveniently be determined with the cursor measurements.

Four-bit DAC signal change.
Open Lightbox

Four-bit DAC signal change.

The R&S®RTA4000 captures and analyzes analog and digital signals synchronized and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTA-B6 waveform and pattern generator for up to 50 Mbit/s is useful for educational purposes and prototype hardware implementation. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns including. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTA4000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The R&S®RTA4000 FFT function is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the high-performance FFT function of the R&S®RTA4000 oscilloscope, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

FFT of a square wave
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluations. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation generates a pulse output at the AUX-OUT connector on the R&S®RTA4000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses DUT quality and stability.

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest signal details of a high dynamic signal are important in power measurements. RDS (on) verification for a MOSFET is one example. The high ADC resolution of R&S®RTA4000 oscilloscopes increases vertical resolution up to 10 bits. Previously unseen signal details are revealed and measurable. The RDS(on) example shows how the slope of the drain-to-source-voltage can be measured while the switch is closed.

Power analysis
Open Lightbox

Power analysis

Analyze input, output and transfer functions of switched-mode power supplies

Available models

Available models
Modèles
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Commençant à

R&S®RTA4004

Numéro de commande 1335.7700P04

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à
6 850 EUR

R&S®RTA4004 + RTA-B243

Numéro de commande 1335.7700P34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à
12 500 EUR

R&S®RTA4004 + RTA-B245

Numéro de commande 1335.7700P54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à
16 300 EUR

R&S®RTA4004 + RTA-B2410

Numéro de commande 1335.7700P64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Commençant à
20 300 EUR
Specifications
Vertical system
Analog channels4
Digital channels (opt.)16
Bandwidth (-3 dB)R&S®RTA4004 (with R&S®RTA-B24x options)200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise timeR&S®RTA4004 (with R&S®RTA-B24x options)1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivitymax. bandwidth in all rangeat 1 MΩ: 500 μV/div to 10 V/div
at 50 Ω: 500 μV/div to 1 V/div
ADC resolution10 bit, up to 16 bit with high resolution decimation
DC gain accuracyoffset and position = 0, maximum operating temperature change of ±5°C after self-alignmentinput sensitivity > 5 mV/div: ±1 % of full scale
input sensitivity ≤ 5 mV/div to ≥ 1 mV/div: ±1.5 % of full scale
input sensitivity < 1 mV/div: ±2.5 % of full scale
Acquisition system
Realtime sampling rate2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory100 Msample (200 Msample, interleaved);
1 Gsample segmented memory
Max. acquisition rate64 000 waveforms/s
(2 000 000 in fast segmented memory mode)
Horizontal system
Timebase rangeselectable between 0.5 ns/div and 500 s/div
Accuracy (after delivery/calibration)±0.5 ppm
Channel-to-channel skew< 200 ps (meas.)
Channel deskew±500 ns
Trigger system
Standard trigger typesedge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus
Optional trigger typesI2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, audio (I2S),ARINC 429, MIL-STD-1553
Trigger sensitivitywith DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.)
Analysis and measurement functions
Automatic measurements32
Cursor measurements4
Waveform mathematics5 equations math on math (addition, subtraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle)
Mask testing
Mask definitionelementary (tolerance mask around the signal)
History and segmented memory
Number of segmentsup to 87 380
Protocol trigger and decode
Supported protocolsI2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429
Waveform generator
Resolution14 bit
Sample rate250 Msample/s
Amplitudehigh Z; 50 Ω20 mV to 10 V (Vpp); 10 mV to 5 V (Vpp)
DC offsethigh Z; 50 Ω±5 V; ±2.5 V
Arbitrarymax. 10 Msample/s; 32k point
Logic analyzer (MSO) functionality
Digital input channels16
MSO memory depthtwo logic probes: 100 Msample for every channel
one logic probe: 200 Msample for every channel
MSO Bandwidth400 MHz (meas.)
MSO sampling rate2.5 Gsample/s; 5 Gsample/s, interleaved
MSO input impedance100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel busesup to 4
General data
DimensionsW × H × D390  mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight3.3 kg (7.3 lb)
Display10.1" WXGA TFT color display (1280 × 800 pixel)
InterfacesUSB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating systemWindows 10, Embedded

Available options

General
Produit
Désignation

Numéro de commande 1335.7823.02

Désignation

Mixed signal option: 400 MHz

Turns R&S®RTA4000 oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).

R&S®RTA-B6

Numéro de commande 1335.7830.02

Désignation

Arbitrary waveform generator

Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTA4000 oscilloscopes.

Bandwidth upgrade
Produit
Désignation
R&S®RTA-B243

Numéro de commande 1335.7846.02

Désignation

Bandwidth upgrade of the R&S®RTA4004 to 350 MHz bandwidth

R&S®RTA-B245

Numéro de commande 1335.7852.02

Désignation

Bandwidth upgrade of the R&S®RTA4004 to 500 MHz bandwidth

R&S®RTA-B2410

Numéro de commande 1335.7869.02

Désignation

Bandwidth upgrade of the R&S®RTA4004 to 1 GHz bandwidth

Serial triggering and decoding
Produit
Désignation

Numéro de commande 1335.7681.02

Désignation

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Numéro de commande 1335.7698.02

Désignation

UART/RS-232/RS-422/RS-485 serial triggering and decoding

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Numéro de commande 1335.7717.02

Désignation

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

Numéro de commande 1335.7723.02

Désignation

I²S/LJ/RJ/TDM triggering and decoding

Triggering and decoding of I²S buses

Numéro de commande 1335.7730.02

Désignation

MIL-1553 serial triggering and decoding

Triggering and decoding of MIL-STD-1553 buses

Numéro de commande 1335.7746.02

Désignation

ARINC 429 serial triggering and decoding

Triggering and decoding of ARINC 429 buses

General analysis
Produit
Désignation

Numéro de commande 1335.7769.02

Désignation

Power analysis

When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).

Numéro de commande 1335.7975.02

Désignation

Frequency Response Analysis (Bode plot)

The R&S®RTA-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

Numéro de commande 1335.7981.02

Désignation

Spectrum analysis and spectrogram

The spectrum analysis option enhances the powerful FFT capability of R&S®RTA4000 oscilloscopes with spectrogram display.

General accessories
Produit
Désignation
R&S®RTB-Z1

Numéro de commande 1333.1728.02

Désignation

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z3

Numéro de commande 1333.1734.02

Désignation

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

R&S®RTB-Z4

Numéro de commande 1335.9290.02

Désignation

Transit case with wheels for R&S®RTB

Numéro de commande 1335.7875.02

Désignation

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

R&S®RT-Z2T

Numéro de commande 1338.0007.02

Désignation

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

R&S®ZZA-RTB2K

Numéro de commande 1333.1711.02

Désignation

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

Passive probes
Produit
Désignation

Numéro de commande 1333.2401.02

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1409.7550.00

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1333.1370.02

Désignation

Passive probe, 38 MHz, 1:1

Active single-ended probes
Produit
Désignation

Numéro de commande 1333.0815.02

Désignation

Active single-ended probe, 1 GHz, BNC interface

Numéro de commande 1418.7007.02

Désignation

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4080.02

Désignation

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.3502.02

Désignation

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Produit
Désignation

Numéro de commande 1410.4715.02

Désignation

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4409.02

Désignation

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Produit
Désignation

Numéro de commande 1800.5006.02

Désignation

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Produit
Désignation

Numéro de commande 1333.0873.02

Désignation

250 MHz passive high voltage probe

Numéro de commande 1409.7720.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1409.7737.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1800.2307.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2107.02

Désignation

100 MHz High voltage differential probe

Numéro de commande 1800.2207.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2007.02

Désignation

100 MHz High voltage differential probe

Current probes
Produit
Désignation

Numéro de commande 1333.0850.02

Désignation

AC/DC 20 kHz current probe

Numéro de commande 1333.0844.02

Désignation

100 kHz current probe

Numéro de commande 1409.8204.02

Désignation

2 MHZ current probe

Numéro de commande 1409.7750K02

Désignation

10 MHZ current probe

Numéro de commande 1409.8210.02

Désignation

10 MHZ Current probe

Numéro de commande 1409.8227.02

Désignation

50 MHZ Current probe

Numéro de commande 1409.7766K02

Désignation

100 MHZ current probe

Numéro de commande 1409.8233.02

Désignation

100 MHZ current probe

Numéro de commande 1409.7772K02

Désignation

120 MHz current probe

Numéro de commande 1801.4932.02

Désignation

120 MHz current probe

R&S®EMC near field probes
Produit
Désignation

Numéro de commande 1147.2736.02

Désignation

E and H near-field probe set

Logic probes
Produit
Désignation
R&S®RT-ZL04

Numéro de commande 1333.0721.02

Désignation

400 MHz logic probe

Probe accessories
Produit
Désignation

Numéro de commande 1409.7789.02

Désignation

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

Numéro de commande 1410.4744.02

Désignation

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.

Numéro de commande 1800.0004.02

Désignation

Power deskew fixture

Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply

Numéro de commande 1326.3641.02

Désignation

3D probe positioner

3D positionier with central tensioning knob for easy clamping and positioning of probes (span width: 200 mm, clamping range: 15 mm)

Application bundles
Produit
Désignation
R&S®RTA-PK1

Numéro de commande 1335.7775.02

Désignation

Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), spectrum analysis and spectrogram (R&S®RTA-K37), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models

R&S®RTA-PK1US*

Numéro de commande 1335.7998.02

Désignation

Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), spectrum analysis and spectrogram (R&S®RTA-K37), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models * ONLY distributed in North America

R&S®RTA4000 – Centre de médias

Vidéos produit – RTA4000
R&S®RTA4000 - Centre de médias

Afficher plus

Vidéos d'application
Vidéos d'applications d'oscilloscopes – Centre de médias

Afficher plus

Ce qui pourrait également vous intéresser

10 ans d’innovation dans les oscilloscopes

Les 10 ans de Rohde & Schwarz en termes d'innovation dans le domaine des oscilloscopes

Plus d'information

Promotion sur les oscilloscopes

Promotion sur les oscilloscopes

Choisissez la bonne promotion R&S en fonction de vos besoins individuels et faîtes d'économies

Plus d'information

Webinaires Rohde & Schwarz

Centre de webinaires dédié aux oscilloscopes pour les applications d'électronique de puissance et de conceptions numériques

Plus d'information

Solution dédiée à la

Conception et aux tests analogique / numérique
Conception et aux tests analogique / numérique

Parcourez les solutions Rohde & Schwarz dédiées à l'intégrité de puissance et de signaux, à la mesure de petits signaux et au dépannage EMI.

Plus d'information

Test en électronique de puissance
Test en électronique de puissance

Laissez nos solutions de test et mesure vous aider pour créer un produit fiable et à faible consommation d'énergie.

Plus d'information

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.