Key Facts
- Bandwidth: 600 MHz to 6 GHz
- Max. sample rate: 20 Gsample/s
- Max. memory depth: 2 Gsample
- Up to 16-bit vertical resolution
- MSO: 16 digital channels, optional, retrofittable
Commençant à 18 000 EUR
Key Facts
Commençant à 18 000 EUR
Offering bandwidths from 600 MHz to 6 GHz, RTO®2000 Series oscilloscopes excel at both time domain and frequency domain testing needs. With excellent signal fidelity, responsiveness of 1M waveforms/sec, and up to 16-bit vertical resolution, quickly measure with confidence. The capacitive touchscreen with SmartGrid makes for easy and intuitive use.
Quick Links
Best oscilloscope performance
See signal details with up to 16 bit vertical resolution in HD mode.
First zone trigger in time and frequency domain.
Touch-optimized operation
Select and activate functions with your finger. Simply drag and drop signals into place and use control gestures to scale and zoom.
Engineered for power measurements
Smallest signal details of a high dynamic signal matter for power measurements. With up to 16 bit of resolution previously unseen signals become visible.
Engineered for multi-domain challenges
The mixed signal option turns the R&S®RTO2000 Digital Oscilloscope into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.
Numéro de commande 1329.7002.02
Numéro de commande 1329.7002.04
Numéro de commande 1329.7002.12
Numéro de commande 1329.7002.14
Numéro de commande 1329.7002.22
Numéro de commande 1329.7002.24
Numéro de commande 1329.7002.32
Numéro de commande 1329.7002.34
Numéro de commande 1329.7002.44
Numéro de commande 1329.7002.64
Vertical system | ||
Analog channels | R&S®RTO2002/R&S®RTO2012 R&S®RTO2022/R&S®RTO2032 | 2 |
R&S®RTO2004/R&S®RTO2014 R&S®RTO2024/R&S®RTO2034 R&S®RTO2044/R&S®RTO2064 | 4 | |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTO2002 and R&S®RTO2004 | 600 MHz |
R&S®RTO2012 and R&S®RTO2014 | 1 GHz | |
R&S®RTO2022 and R&S®RTO2024 | 2 GHz | |
R&S®RTO2032 and R&S®RTO2034 | 3 GHz | |
R&S®RTO2044 | 4 GHz | |
R&S®RTO2064 | on 4 channels: 4 GHz on 2 channels: 6 GHz | |
Rise time | R&S®RTO2002 and R&S®RTO2004 | 583 ps |
R&S®RTO2012 and R&S®RTO2014 | 350 ps | |
R&S®RTO2022 and R&S®RTO2024 | 175 ps | |
R&S®RTO2032 and R&S®RTO2034 | 116 ps | |
R&S®RTO2044 | 100 ps | |
R&S®RTO2064 | on 4 channels: 100 ps on 2 channels: 76ps | |
Input impedance | 50 Ω ±1.5 % 1 MΩ ±1 % at 15 pF (meas.) | |
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 1 mV/div to 1 V/div, 500 μV to 1 V (optional); 1 MΩ: 1 mV/div to 10 V/div, 500 μV to 10 V (optional) |
Acquisition system | ||
Realtime sampling rate | R&S®RTO200x/201x/202x/203x | max 10 Gsample/s on each channel |
R&S®RTO2044/2064 | max. 10 Gsample/s on 4 channels max. 20 Gsample/s on 2 channels | |
Acquisition memory | standard configuration, per channel/1 channel active | R&S®RTO2000: 2-channel-model: 50 /100 Msample R&S®RTO2000: 4-channel-model 50 /200 Msample |
max. upgrade (R&S®RTO-B110 option), per channel/1 channel active | R&S®RTO2000: 2-channel-model: 1/2 Gsample R&S®RTO2000: 4-channel-model: 1/2 Gsample | |
Max. acquisition rate | continuous aquisition and display, 10 Gsample/s, 1 ksample | 1 000 000 waveforms/s |
ultra-segmented-mode | < 300 ns blind time | |
Decimation modes | any combination of decimation mode and waveform arithmetics on up to 3 waveforms per channel | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Interpolation modes | linear, sin(x)/x, sample&hold | |
Deembedding (optional) | yes | |
Horizontal system | ||
Timebase range | 25 ps/div to 10,000 s/div | |
Accuracy (after delivery/calibration) | after delivery/calibration R&S®RTO-B4 option | ±5 ppm ±0.02 ppm |
Trigger system | ||
Standard Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video | |
Optional Trigger types | serial bus trigger, zone trigger | |
Zone trigger (opt.) | in time- and frequency domain | logical combination of max. 8 polygons, intersect or not intersect source: measurement channels, spectrum, math functions |
Trigger sensitivity | definition of trigger hysteresis | automatic or manually adjustable from 0 div to 5 div |
Analysis and measurement functions | ||
Automatic measurements | 47 | |
Cursor measurements | 4 | |
Waveform mathematics | advanced (formula editor) | |
Mask testing | ||
Mask definition | advanced (user-configurable, hardware based) | |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO Memory depth | 200 Mpts per channel | |
MSO Bandwidth | 400 MHz | |
MSO sampling rate | 5 Gsample/s per channel | |
General data | ||
Dimensions | W x H x D | 427 mm x 249 mm x 204 mm (16.81 in x 9.8 in x 8.03 in) |
Weight | 9.6 kg (21.2 lbs) | |
Display | 12.1" LC TFT capacitive color touchscreen, 1280 x 800 pixels (XGA) | |
Interfaces | 1 Gbps LAN, type A: 2 x USB 3.1, 2 x USB 2.0, type B: 1 x USB 3.1, GPIB (optional), DVI and display port for external monitor, external trigger, trigger output | |
Operating system | Windows |
Numéro de commande 1326.3558.02
Mixed signal option: 16 digital channels, 5 GSa/s, 400 MHz bandwidth
Adds 16 digital channels to R&S®RTO2000 oscilloscopes. (DSO to MSO upgrade)
Numéro de commande 1333.0738.02
Digital Extension Port for R&S®RTO2000
Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTO-B1
Numéro de commande 1304.8305.02
OCXO 10 MHz
Increase time base accuracy to ±0.02 ppm after calibration
Numéro de commande 1329.7054.02
Arbitrary waveform generator
Add 2-channel 500 MSample/s waveform generator and 8-channel pattern generator
Numéro de commande 1333.2030.02
Differential 16 GHz pulse source for R&S®RTO2000 Oscilloscope
Numéro de commande 1304.8311.03
GPIB Interface
Add GPIB interface
Numéro de commande 1329.7048.02
Additional SSD
Comes pre-installed with operating system and scope application
Numéro de commande 1329.7060.02
Memory upgrade to 100 Msample on 4 channels, 200 Msample on 2 channels, 400 Msample on 1 channel
Numéro de commande 1329.7077.02
Memory upgrade to 200 Msample on 4 channels, 400 Msample on 2 channels, 800 Msample on 1 channel
Numéro de commande 1329.7083.02
Memory upgrade to 400 Msample on 4 channels, 800 Msample on 2 channels, 800 Msample on 1 channel
Numéro de commande 1329.7090.02
Memory upgrade to 1 Gsample on 4 channels, 2 Gsample on 2 channels, 2 Gsample on 1 channel
Numéro de commande 1329.7102.02
Bandwidth upgrade of the R&S®RTO2002/R&S®RTO2004 to 1 GHz bandwidth, incl. calibration
Numéro de commande 1329.7119.02
Bandwidth upgrade of the R&S®RTO2002/R&S®RTO2004 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1329.7125.02
Bandwidth upgrade of the R&S®RTO2002/R&S®RTO2004 to 3 GHz bandwidth, incl. calibration
Numéro de commande 1329.7131.02
Bandwidth upgrade of the R&S®RTO2004 to 4 GHz bandwidth, incl. calibration
Numéro de commande 1329.7148.02
Bandwidth upgrade of the R&S®RTO2004 to 6 GHz bandwidth, incl. calibration
Numéro de commande 1329.7154.02
Bandwidth upgrade of the R&S®RTO2012/R&S®RTO2014 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1329.7160.02
Bandwidth upgrade of the R&S®RTO2012/R&S®RTO2014 to 3 GHz bandwidth, incl. calibration
Numéro de commande 1329.7177.02
Bandwidth upgrade of the R&S®RTO2014 to 4 GHz bandwidth, incl. calibration
Numéro de commande 1329.7183.02
Bandwidth upgrade of the R&S®RTO2014 to 6 GHz bandwidth, incl. calibration
Numéro de commande 1329.7190.02
Bandwidth upgrade of the R&S®RTO2022/R&S®RTO2024 to 3 GHz bandwidth, incl. calibration
Numéro de commande 1329.7202.02
Bandwidth upgrade of the R&S®RTO2024 to 4 GHz bandwidth, incl. calibration
Numéro de commande 1329.7225.02
Bandwidth upgrade of the R&S®RTO2034 to 4 GHz bandwidth, incl. calibration
Numéro de commande 1329.7419.02
High definition mode.
Numéro de commande 1329.7377.02
Jitter analysis
Numéro de commande 1329.7383.02
Clock data recovery
Numéro de commande 1329.7425.02
Spectrum analysis
Numéro de commande 1329.7431.02
Zone trigger
Numéro de commande 1329.7502.02
Power analysis
Numéro de commande 1803.6784.02
Python interface for user defined math
Numéro de commande 1326.3058.02
Deembedding option for compensation of channel effects
Numéro de commande 1326.3087.02
TDR/TDT analysis
Numéro de commande 1801.4832.02
Jitter decomposition
Decomposition of jitter components, display of step response, histograms, synthetic eye diagrams, spectrum and BER-bathtub curve
Numéro de commande 1802.9450.02
Jitter and noise decomposition
Numéro de commande 1329.7260.02
I²C/SPI triggering and decoding
Numéro de commande 1329.7277.02
UART/RS232/422/485 triggering and decoding
Numéro de commande 1329.7283.02
CAN/LIN triggering and decoding
Numéro de commande 1329.7290.02
FlexRay™ triggering and decoding
Numéro de commande 1329.7302.02
I²S triggering and decoding
Numéro de commande 1329.7319.02
MIL-1553 triggering and decoding
Numéro de commande 1329.7325.02
ARINC 429 triggering and decoding
Numéro de commande 1329.7331.02
Ethernet serial decoding
Numéro de commande 1329.7348.02
CAN-FD triggering and decoding
Numéro de commande 1329.7354.02
SENT triggering and decoding
Numéro de commande 1801.2846.02
Bus analysis
Numéro de commande 1329.7519.02
MIPI RFFE triggering and decoding
Numéro de commande 1329.7525.02
MIPI D-PHY triggering and decoding
Numéro de commande 1333.0267.02
M-PHY triggering and decoding
Numéro de commande 1329.7531.02
MANCHESTER/NRZ triggering and decoding
Numéro de commande 1329.7548.02
8b10b triggering and decoding
Numéro de commande 1329.7554.02
MDIO triggering and decoding
Numéro de commande 1333.0596.02
100BASE-T1 triggering and decoding
Numéro de commande 1801.4503.02
1000Base-T1 T&D
Numéro de commande 1329.7560.02
USB 1.0/1.1/2.0/HSIC triggering and decoding
Numéro de commande 1326.3112.02
USB 3.1 Gen 1 triggering and decoding
Numéro de commande 1326.3135.02
USB power delivery triggering and decoding
Numéro de commande 1337.9123.02
USB-SSIC triggering and decoding
Numéro de commande 1326.2868.02
SpaceWire triggering and decoding
Numéro de commande 1326.3741.02
PCIe 1.1/2.0 triggering and decoding
Numéro de commande 1326.3164.02
CXPI Serial Triggering and Decoding
Numéro de commande 1329.7454.02
Automated compliance test solution for USB 2.0
Numéro de commande 1329.7460.02
Automated compliance test solution for 10M/100M/1G-Base-T/EE Ethernet
Numéro de commande 1329.7477.02
Automated compliance test solution for 2.5/5/10G-Base-T Ethernet
Numéro de commande 1329.7483.02
Automated compliance test solution for 100Base-T1/BroadR-Reach® Ethernet
Numéro de commande 1329.7490.02
Automated compliance test solution for MIPI-D-PHY
Numéro de commande 1803.6584.02
R&S®MIPI D-PHY compliance test software, V2.5
Numéro de commande 1326.0920.02
Automated compliance test of PCI Express Gen 1.1 and 2.0 up to 2.5 Gbit/s data rates
Numéro de commande 1337.8591.02
Automated compliance test solution for 1000BASE-T1 Ethernet
Numéro de commande 1801.4510.02
10BASE-T1 Ethernet compliance test
Numéro de commande 1337.8891.02
DDR3/DDR3L/LPDDR3 Signal integrity debug and compliance test software
Numéro de commande 1333.0444.02
Automated compliance test solution for eMMC
Numéro de commande 1326.4419.02
ScopeSuite automation
Numéro de commande 1329.7360.02
I/Q software interface
Converts modulated signals to I/Q data for further processing.
Numéro de commande 1345.1011.06
Software
Brings the experience and power of Rohde & Schwarz signal analysis to PC and cloud
Numéro de commande 1310.0002K02
License dongle
Numéro de commande 1320.7516.06
Pulse measurements application
Numéro de commande 1345.1286.06
Multi-channel pulse measurements
Numéro de commande 1320.7539.06
Analog modulation analysis (AM/FM/φM)
Modulation analysis for AM/FM/φM modulated single carriers
Numéro de commande 1345.1970.06
Bluetooth® BR/EDR/LE measurements
Numéro de commande 1320.7574.06
GSM measurements
GSM/EDGE/ EDGE Evolution
Numéro de commande 1320.7868.06
Transient measurements
Transient analysis
Numéro de commande 1320.7880.06
Transient hop measurements
Transient analysis, requires R&S®VSE-K60
Numéro de commande 1320.7874.06
Transient chirp measurements
Transient analysis, requires R&S®VSE-K60
Numéro de commande 1320.7522.06
Vector signal analysis
Numéro de commande 1345.1211.06
Multi-modulation analysis
R&S®VSE-K70 option required
Numéro de commande 1345.1228.06
BER PRBS measurements
R&S®VSE-K70 option required
Numéro de commande 1320.7580.06
3GPP FDD measurements
WCDMA signal analysis
Numéro de commande 1320.7597.06
IEEE 802.11a/b/g measurements
WLAN signal analysis
Numéro de commande 1320.7680.02
IEEE 802.11p measurements
WLAN signal analysis
Numéro de commande 1320.7600.06
IEEE 802.11n measurements
WLAN signal analysis
Numéro de commande 1320.7616.06
IEEE 802.11ac measurements
WLAN signal analysis
Numéro de commande 1345.1411.06
IEEE 802.11ax measurements
WLAN signal analysis
Numéro de commande 1320.7922.06
OFDM signal analysis
Numéro de commande 1320.7545.06
EUTRA/LTE FDD uplink and downlink measurement application
LTE signal analysis
Numéro de commande 1320.7551.06
EUTRA/LTE advanced and MIMO (downlink)
LTE signal analysis
Numéro de commande 1320.7568.06
EUTRA/LTE TDD uplink and downlink measurement application
LTE signal analysis
Numéro de commande 1320.7900.06
EUTRA/LTE
Narrowband IoT analysis
Numéro de commande 1309.9574.06
5G NR uplink and downlink measurement application
Numéro de commande 1345.1305.06
5G MIMO measurements
Numéro de commande 1345.1392.06
5G NR R16 measurements
Numéro de commande 1345.1463.06
HRP UWB measurements
Numéro de commande 1345.1663.02
5G NR R17 measurements
Numéro de commande 1350.7020.06
O-RAN measurements
Numéro de commande 1345.2001.06
OneWeb reverse link measurement application for R&S®VSE software. This application can be used to analyze OneWeb SC-FDMA signals.
Numéro de commande 1309.9580.06
User-defined Frequency Correction by SnP File
Numéro de commande 1320.7622.81
Software maintenance
Numéro de commande 1801.3836.02
Upgrade to Windows 10
Numéro de commande 1333.0096.02
Front Cover
Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope
Numéro de commande 1304.9118.02
Soft Case
Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories
Numéro de commande 1317.7025.02
Transit case
Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport
Numéro de commande 1317.7031.02
Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes
Numéro de commande 1304.8286.00
19" Rackmount Adapter
For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 19" rack with 6U heigth
Numéro de commande 1338.0007.02
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Numéro de commande 1317.3420.02
Test fixture set for USB2.0 compliance
Test fixture for USB 1.0/1.1/2.0 compliance tests. Supported by R&S®RTO-K21 USB compliance test option.
Numéro de commande 1317.5522.02
Test fixture for 10/100/1000BASE-T, 10G-BaseT and BroadR-Reach Ethernet
Supported by R&S®RTO-K22, R&S®RTO-K23 and R&S®RTO-K24 Ethernet compliance test options.
Numéro de commande 5025.0670.02
Frequency converter
for 100BASE-T1/BroadR-Reach compliance test
Numéro de commande 1333.0880.02
10BASE-TE Energy Efficient Ethernet Test Fixture
Numéro de commande 1333.0896.02
Ethernet Probing Fixture
(directional, link partner, load)
Numéro de commande 1337.8579.02
Frequency converter board
for 1000BASE-T1 compliance test
Numéro de commande 1801.3688.02
Automotive T&D Fixture
Automotive Ethernet probing fixture including 2 SMA adapters RT-ZF7A
Numéro de commande 1801.4126.02
SMA Adapter
High precision adapter board from automotive connector to SMA
Numéro de commande 1802.9680.02
SMA adapter for PoDL
High precision adapter board from Industrial Ethernet connectors to SMA
Numéro de commande 1801.3694.02
Automotive Ethernet Compliance Fixture
Test fixture for 100BASE-T1 and 1000BASE-T1 compliance testing according to IEEE and OPEN TC8
Numéro de commande 1317.5639.02
1000BASE-T Jitter Test Cable
1000Base-T jitter test cable for the R&S®RTO-K22 Ethernet compliance test solution.
Numéro de commande 1800.0004.02
Power deskew fixture
Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply
Numéro de commande 1409.7550.00
Passive probe, 500 MHz, 10:1
Numéro de commande 1409.7608.02
Transmission line probe, 8 GHz, passive
Numéro de commande 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4309.02
Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1418.7307.02
Active single-ended probe, 6 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4609.02
Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.5205.02
Active differential probe, 4.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1800.4700.02
Modular probe amplifier module, 1.5 GHz
Numéro de commande 1419.3005.02
Modular probe amplifier module, 3 GHz
Numéro de commande 1419.3105.02
Modular probe amplifier module, 6 GHz
Numéro de commande 1419.3205.02
Modular probe amplifier module, 9 GHz
Numéro de commande 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Numéro de commande 1800.5406.02
Power rail probe, 4 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1326.0259.02
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs
Numéro de commande 1326.0259.04
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs
Numéro de commande 1333.0873.02
250 MHz passive high voltage probe
Numéro de commande 1409.7720.02
400 MHz passive high voltage probe
Numéro de commande 1409.7737.02
400 MHz passive high voltage probe
Numéro de commande 1800.2107.02
100 MHz High voltage differential probe
Numéro de commande 1800.2207.02
200 MHz High voltage differential probe
Numéro de commande 1800.2007.02
100 MHz High voltage differential probe
Numéro de commande 1333.0850.02
AC/DC 20 kHz current probe
Numéro de commande 1333.0844.02
100 kHz current probe
Numéro de commande 1409.8204.02
2 MHZ current probe
Numéro de commande 1409.7750K02
10 MHZ current probe
Numéro de commande 1409.8210.02
10 MHZ Current probe
Numéro de commande 1409.8227.02
50 MHZ Current probe
Numéro de commande 1409.7766K02
100 MHZ current probe
Numéro de commande 1409.8233.02
100 MHZ current probe
Numéro de commande 1409.7772K02
120 MHz current probe
Numéro de commande 1801.4932.02
120 MHz current probe
Numéro de commande 1147.2736.02
E and H near-field probe set
Numéro de commande 1326.4202.02
Trigger and decode bundle option
Decode more than 37 serial protocols with the R&S®RTO trigger and decode software bundle. T&D bundle includes: I²C/SPI, UART/RS232, CAN/LIN, FlexRay, I²S, MIL, ARINC, Ethernet, 100BASE-T1,CAN-FD, SENT, MIPI-RFFE, MIPI-D-PHY, MIPI-M-PHY, custom, 8b10b, MDIO, USB2.0. USB3.1gen1, USB-PD, USB-SSIC, SpaceWire, PCIe2.0. CXPI.
Produits associés
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz
1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").
2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.
3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.
4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.
5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :
Prix : 1x oscilloscope numérique R&S®RTB2000
6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.
7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.
8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.
9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.
10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.
11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.
12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.
13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.