Key Facts

  • 6 GHz maximum bandwidth
  • 1 million waveforms per second
  • 9.4 ENOB for ultimate signal integrity
  • 2 Gpoints maximum memory
  • Exclusive frequency zone trigger

Commençant à 24 000 EUR

The oscilloscope you can trust

The R&S®RTO6 is the oscilloscope you can trust. Engineered to deliver reliable results, it acts as a sophisticated laboratory companion to solve measurement problems fast and keep you on schedule. The R&S®RTO6 oscilloscope series leverages the engineer’s expertise and builds your measurement confidence by achieving deep insights, whenever needed.

The R&S®RTO6 oscilloscope series provides superior signals to insight for your applications. The large 15.6" touchscreen and a new GUI, combined with high waveform update rate, excellent signal fidelity, digital trigger and deep responsive memory serve as a fully integrated test solution for frequency, protocol and logic analysis. The R&S®RTO6 oscilloscope series’ rich measurement toolset combined with a streamlined user interface helps you quickly solve circuit issues from simple to complex.

Caractéristiques & avantages

Finding signal anomalies quickly

... with an unparalleled update rate

  • 1 000 000 waveforms/s
  • Available with active histograms, masks or cursor measurements
  • Quickly and reliably detect sporadic signal faults
  • Mask testing: Quick configuration and fast results

Typical update rate (left) vs. 1 million waveforms/s (right)
Open Lightbox

Typical update rate (left) vs. 1 million waveforms/s (right)

Capturing all signal details

... with excellent signal integrity

  • Low-noise frontends and minimized crosstalk
  • Flat frequency response
  • Excellent longterm stability
  • Outstanding A/D converter with ultra-wide SFDR

Measured frequency response of the R&S®RTO6
Open Lightbox

Measured frequency response of the R&S®RTO6

Seeing more

... with up to 16 bit resolution

  • 16 bit resolution for measuring small signal amplitudes
  • High acquisition rate and full functionality
  • Full sample rate – No aliasing
  • User-selectable filtering: Reduced noise, increased ENOB

Typical vertical resolution (left) vs. 16 bit resolution HD Mode (right)
Open Lightbox

Typical vertical resolution (left) vs. 16 bit resolution HD Mode (right)

Finding complex signal details

... with advanced trigger capabilities

  • Patented digital trigger system
  • High trigger sensitivity at full bandwidth
  • Isolate smallest signal details
  • Zone trigger in time and frequency domain

Trigger not possible (left) vs. straightforward triggering with digital trigger and HD Mode (right)
Open Lightbox

Trigger not possible (left) vs. straightforward triggering with digital trigger and HD Mode (right)

Measuring more

... with deep and responsive memory

  • Maximized memory: 200 Mpoints standard
  • 2 Gpoints optional
  • Segmented memory to capture distant trigger events
  • History mode to analyze previous trigger events
  • Search and navigation: find faults fast

Single-shot versus segmented acquisition
Open Lightbox

Single-shot versus segmented acquisition

Available models

Available models
Modèles
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO

R&S®RTO64

Numéro de commande 1802.0001.04

Bandwidth
600 MHz - 6 GHz
Channels
4
Sample rate
up to 20 Gsample/s
Max. memory depth
2 Gpts
Optional MSO
16 digital channels
Specifications
Vertical system
Analog channels 4
Bandwidth (-3 dB) R&S®RTO64 with R&S®RTO6-B90 option 600 MHz
(one bandwidth option mandatory) R&S®RTO64 with R&S®RTO6-B91 option 1 GHz
R&S®RTO64 with R&S®RTO6-B92 option 2 GHz
R&S®RTO64 with R&S®RTO6-B93 option 3 GHz
R&S®RTO64 with R&S®RTO6-B94 option 4 GHz
R&S®RTO64 with R&S®RTO6-B96 option on 2 channels: 6 GHz
on 4 channels: 4 GHz
Rise time R&S®RTO64 with R&S®RTO6-B90 option 635 ps
R&S®RTO64 with R&S®RTO6-B91 option 375 ps
R&S®RTO64 with R&S®RTO6-B92 option 210 ps
R&S®RTO64 with R&S®RTO6-B93 option 145 ps
R&S®RTO64 with R&S®RTO6-B94 option 110 ps
R&S®RTO64 with R&S®RTO6-B96 option 77 ps
Vertical resolution 16-bit system architecture
Effective number of bits / ENOB (meas.) at 50 Ω, 50 mV/div, 10 MHz input signal with 90 % full-scale
50 MHz
100 MHz
200 MHz
300 MHz
500 MHz
1 GHz
2 GHz
4 GHz
6 GHz

9.4
9.0
8.6
8.2
8.1
7.7
7.1
6
6
RMS noise floor at 50 Ω, 1 mV/div, 10 MHz bandwidth filter 10 µV (meas.)
Input impedance 50 Ω ±1.5 %
1 MΩ ±1 % at 15 pF (meas.)
Input sensitivity max. bandwidth in all ranges 50 Ω: 1 mV/div to 1 V/div
1 MΩ: 1 mV/div to 10 V/div
Acquisition system
Realtime sampling rate R&S®RTO6-B90, R&S®RTO6-B91, R&S®RTO6-B92, R&S®RTO6-B93 options max 10 Gsample/s on each channel
R&S®RTO6-B94, R&S®RTO6-B96 options max. 10 Gsample/s on 4 channels
max. 20 Gsample/s on 2 channels
Acquisition memory standard  200 Mpoints on 4 channels
400 Mpoints on 2 channels
800 Mpoints on 1 channel
R&S®RTO6-B104 option  400 Mpoints on 4 channels
800 Mpoints on 2 channels
800 Mpoints on 1 channel
R&S®RTO6-B110 option  1 Gpoint on 4 channels
2 Gpoints on 2 channels (restriction: 1 Gpoint on 2 channels when channel 1 and channel 2 or channel 3 and channel 4 are turned on)
2 Gpoints on 1 channel
Max. acquisition rate 1 000 000 waveforms/s
Decimation modes any combination of decimation mode and waveform arithmetics on up to 3 waveforms per channel sample, peak detect, high resolution, root mean square
Waveform arithmetics off, envelope, average
Interpolation modes linear, sin(x)/x, sample&hold
Deembedding (optional) yes
Horizontal system
Timebase range 25 ps/div to 10,000 s/div
Timebase Accuracy after delivery/calibration ±10 ppb
Trigger system
Standard Trigger types edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video, zone trigger
Optional Trigger types serial bus trigger
Trigger sensitivity definition of trigger hysteresis automatic or manually adjustable
from 0 div to 5 div
Analysis and measurement
Automatic measurements 47
Cursor measurements 4
Waveform mathematics advanced (formula editor)
Mask testing
Mask definition advanced (user-configurable, hardware based)
Logic analyzer (MSO) functionality
Digital input channels 16
MSO Memory depth 200 Mpts per channel
MSO Bandwidth 400 MHz
MSO sampling rate 5 Gsample/s per channel
General data
Dimensions W x H x D 450 mm × 315 mm × 204 mm
(17.72 in × 12.40 in × 8.03 in) 
Weight 10.7 kg (23.59 lb)
Interfaces 1 Gbps LAN, type A: 2 x USB 3.1, 2 x USB 2.0, type B: 1 x USB 3.1, GPIB (optional), HDMI and DisplayPort for external monitor, external trigger, trigger output
Display 15.6" capacitive touchscreen, resolution: 1920 x 1080 pixel (Full HD)
Operating system Windows

Available options

Hardware options
Produit
Désignation

Numéro de commande 1801.6741.02

Désignation

Mixed signal option: 16 digital channels, 5 GSa/s, 400 MHz bandwidth

Numéro de commande 1801.6735.02

Désignation

Digital Extension Port for R&S®RTO6. Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTO-B1.

Numéro de commande 1801.6758.02

Désignation

Arbitrary waveform generator: 2-channel 500 MSample/s waveform generator and 8-channel pattern generator

R&S®RTO6-B7

Numéro de commande 1801.6764.02

Désignation

Differential 16 GHz pulse source for R&S®RTO6 Oscilloscope

Contains an accessory bag with 2 SMA cables, 4 SMA terminations, 2 SMA(f) to SMA(f) adapters, 2 SMA shorts and 1 ESD wrist strap with grounding cord.

R&S®RTO6-B10

Numéro de commande 1801.6770.02

Désignation

GPIB Interface

R&S®RTO6-B19

Numéro de commande 1801.6787.02

Désignation

Replacement SSD, pre-installed with OS and oscilloscope firmware

Memory upgrade
Produit
Désignation
R&S®RTO6-B104

Numéro de commande 1801.6793.02

Désignation

Memory upgrade to 400 Mpoints on 4 channels, 800 Mpoints on 2 channels

R&S®RTO6-B110

Numéro de commande 1801.6806.04

Désignation

Memory upgrade to 1 Gpoints on 4 channels, 2 Gpoints on 2 channels

Bandwidth upgrade
Produit
Désignation
R&S®RTO6-B201

Numéro de commande 1801.7277.02

Désignation

Upgrade of the R&S®RTO6-B90 option to 1 GHz bandwidth

R&S®RTO6-B202

Numéro de commande 1801.7283.02

Désignation

Upgrade of the R&S®RTO6-B90 option to 2 GHz bandwidth

R&S®RTO6-B203

Numéro de commande 1801.7290.02

Désignation

Upgrade of the R&S®RTO6-B90 option to 3 GHz bandwidth

R&S®RTO6-B204

Numéro de commande 1801.7302.02

Désignation

Upgrade of the R&S®RTO6-B90 option to 4 GHz bandwidth

R&S®RTO6-B206

Numéro de commande 1801.7319.02

Désignation

Upgrade of the R&S®RTO6-B90 option to 6 GHz bandwidth

R&S®RTO6-B212

Numéro de commande 1801.7325.02

Désignation

Upgrade of the R&S®RTO6-B91 option to 2 GHz bandwidth

R&S®RTO6-B213

Numéro de commande 1801.7331.02

Désignation

Upgrade of the R&S®RTO6-B91 option to 3 GHz bandwidth

R&S®RTO6-B214

Numéro de commande 1801.7348.02

Désignation

Upgrade of the R&S®RTO6-B91 option to 4 GHz bandwidth

R&S®RTO6-B216

Numéro de commande 1801.7354.02

Désignation

Upgrade of the R&S®RTO6-B91 option to 6 GHz bandwidth

R&S®RTO6-B223

Numéro de commande 1801.7360.02

Désignation

Upgrade of the R&S®RTO6-B92 option to 3 GHz bandwidth

R&S®RTO6-B224

Numéro de commande 1801.7377.02

Désignation

Upgrade of the R&S®RTO6-B92 option to 4 GHz bandwidth

R&S®RTO6-B226

Numéro de commande 1801.7383.02

Désignation

Upgrade of the R&S®RTO6-B92 option to 6 GHz bandwidth

R&S®RTO6-B234

Numéro de commande 1801.7390.02

Désignation

Upgrade of the R&S®RTO6-B93 option to 4 GHz bandwidth

R&S®RTO6-B236

Numéro de commande 1801.7402.02

Désignation

Upgrade of the R&S®RTO6-B93 option to 6 GHz bandwidth

R&S®RTO6-B246

Numéro de commande 1801.7419.02

Désignation

Upgrade of the R&S®RTO6-B94 option to 6 GHz bandwidth

General analysis
Produit
Désignation

Numéro de commande 1801.6829.02

Désignation

Jitter analysis

Numéro de commande 1801.6835.02

Désignation

Clock data recovery

Numéro de commande 1801.6858.02

Désignation

Power analysis

Numéro de commande 1801.6870.02

Désignation

Spectrum analysis

R&S®RTO6-K39

Numéro de commande 1803.6778.02

Désignation

Python interface for user defined math

Numéro de commande 1801.6887.02

Désignation

Deembedding for compensation of channel effects

Numéro de commande 1801.8109.02

Désignation

Embedding & Equalization

Embedding user-configurable components, predistortion at TX  and equalization at RX via CTLE, FFE or DFE 

Numéro de commande 1801.6893.02

Désignation

TDR/TDT analysis

Numéro de commande 1801.6906.02

Désignation

Jitter decomposition: Decomposition of jitter components, display of step response, histograms, synthetic eye diagrams, spectrum and BER-bathtub curve

Numéro de commande 1801.7677.02

Désignation

Jitter and noise decomposition

Numéro de commande 1801.8050.02

Désignation

PAM-N Analysis

Enabled for advanced jitter & noise, advanced eye and selected automated time/amplitude and eye measurements. 

Numéro de commande 1801.8080.02

Désignation

Advanced Eye Analysis

Including SW-CDR and comprehensive Mask test library.

Serial triggering and decoding
Produit
Désignation

Numéro de commande 1801.6864.02

Désignation

Bus analysis: Bus measurements and analysis functions

Numéro de commande 1801.7019.02

Désignation

Trigger & decode package "Low speed serial buses": I2C, SPI, RS-232, UART, I2S, LJ, RJ, TDM, Manchester, NRZ

Numéro de commande 1801.7025.02

Désignation

Trigger & decode package "Automotive protocols": CAN incl. CAN-dbc file import, CAN-FD, LIN, FlexRay™ incl.
Fibex file import, SENT, CXPI

Numéro de commande 1801.7031.02

Désignation

Trigger & decode package "Aerospace protocols": MIL-STD-1553, ARINC 429, SpaceWire

Numéro de commande 1801.7048.02

Désignation

Ethernet protocols trigger and decode package: 10BASE-T, 100BASE-TX, MDIO

Numéro de commande 1801.7054.02

Désignation

Trigger & decode MIPI RFFE

Numéro de commande 1801.7060.02

Désignation

Trigger & decode package "Automotive Ethernet": IEEE 100BASE-T1, IEEE 1000BASE-T1

Numéro de commande 1801.7077.02

Désignation

Trigger & decode package "USB protocols": USB 1.0/1.1, USB 2.0/HSIC, USB 3.1 Gen 1, USB Power Delivery (USB-PD), USB SSIC

Numéro de commande 1801.7083.02

Désignation

Trigger & decode package "MIPI M-PHY, D-PHY": MIPI D-PHY, MIPI M-PHY, UniPro, decoding for DSI und CSI-2

Numéro de commande 1801.7090.02

Désignation

"PCI Express" trigger and decode package : 8b10b (up to 6.25 Gbit/s), PCI Express revision 1.x/2.x

R&S®RTO6-TDBDL

Numéro de commande 1801.7725.02

Désignation

Trigger and decode bundle: Unlocks trigger and decode functionality for all protocols included in R&S®RTO6-K500/-K510/-K520/-K530/-K540/-K550/-K560/-K570/-K580/-K590

Compliance tests
Produit
Désignation

Numéro de commande 1801.6912.02

Désignation

USB 2.0 compliance test

Numéro de commande 1801.6929.02

Désignation

10M/100M/1G-BASE-T/EE Ethernet compliance test

Numéro de commande 1801.6935.02

Désignation

Ethernet compliance test (2.5/5/10GBASE-T)

Numéro de commande 1801.6941.02

Désignation

IEEE 100BASE-T1 compliance test

Numéro de commande 1801.6958.02

Désignation

MIPI-D-PHY compliance test

Numéro de commande 1803.6578.02

Désignation

R&S®MIPI D-PHY compliance test software, V2.5

Numéro de commande 1801.6964.02

Désignation

PCI Express 1.1/2.0 compliance test

Numéro de commande 1801.6970.02

Désignation

IEEE 1000BASE-T1 compliance test

Numéro de commande 1801.6987.02

Désignation

IEEE 10BASE-T1 compliance test

Numéro de commande 1801.7890.02

Désignation

MGBASE-T1 compliance test

Numéro de commande 1801.6993.02

Désignation

DDR3/DDR3L/LPDDR3 signal integrity debug and compliance test

Numéro de commande 1801.7160.02

Désignation

eMMC compliance test

Numéro de commande 1801.7690.02

Désignation

R&S®ScopeSuite automation

Vector signal analysis
Produit
Désignation

Numéro de commande 1801.6812.02

Désignation

I/Q software interface: Converts modulated signals to I/Q data for further processing

Numéro de commande 1345.1011.06

Désignation

Software

Brings the experience and power of Rohde & Schwarz signal analysis to PC and cloud

R&S®FSPC

Numéro de commande 1310.0002K02

Désignation

License dongle

R&S®VSE-K6

Numéro de commande 1320.7516.06

Désignation

Pulse measurements application

R&S®VSE-K6A

Numéro de commande 1345.1286.06

Désignation

Multi-channel pulse measurements

R&S®VSE-K7

Numéro de commande 1320.7539.06

Désignation

Analog modulation analysis (AM/FM/φM)

Modulation analysis for AM/FM/φM modulated single carriers

R&S®VSE-K8

Numéro de commande 1345.1970.06

Désignation

Bluetooth® BR/EDR/LE measurements

R&S®VSE-K10

Numéro de commande 1320.7574.06

Désignation

GSM measurements

GSM/EDGE/ EDGE Evolution

R&S®VSE-K60

Numéro de commande 1320.7868.06

Désignation

Transient measurements

Transient analysis

R&S®VSE-K60H

Numéro de commande 1320.7880.06

Désignation

Transient hop measurements

Transient analysis, requires R&S®VSE-K60

R&S®VSE-K60C

Numéro de commande 1320.7874.06

Désignation

Transient chirp measurements

Transient analysis, requires R&S®VSE-K60

R&S®VSE-K60P

Numéro de commande 1345.2230.06

Désignation

Transient phase noise measurements

R&S®VSE-K70

Numéro de commande 1320.7522.06

Désignation

Vector signal analysis

R&S®VSE-K70M

Numéro de commande 1345.1211.06

Désignation

Multi-modulation analysis

R&S®VSE-K70 option required

R&S®VSE-K70P

Numéro de commande 1345.1228.06

Désignation

BER PRBS measurements

R&S®VSE-K70 option required

R&S®VSE-K72

Numéro de commande 1320.7580.06

Désignation

3GPP FDD measurements

WCDMA signal analysis

R&S®VSE-K91

Numéro de commande 1320.7597.06

Désignation

IEEE 802.11a/b/g measurements

WLAN signal analysis

R&S®VSE-K91P

Numéro de commande 1320.7680.02

Désignation

IEEE 802.11p measurements

WLAN signal analysis

R&S®VSE-K91N

Numéro de commande 1320.7600.06

Désignation

IEEE 802.11n measurements

WLAN signal analysis

R&S®VSE-K91AC

Numéro de commande 1320.7616.06

Désignation

IEEE 802.11ac measurements

WLAN signal analysis

R&S®VSE-K91AX

Numéro de commande 1345.1411.06

Désignation

IEEE 802.11ax measurements

WLAN signal analysis

R&S®VSE-K96

Numéro de commande 1320.7922.06

Désignation

OFDM signal analysis

R&S®VSE-K100

Numéro de commande 1320.7545.06

Désignation

EUTRA/LTE FDD uplink and downlink measurement application

LTE signal analysis

R&S®VSE-K102

Numéro de commande 1320.7551.06

Désignation

EUTRA/LTE advanced and MIMO (downlink)

LTE signal analysis

R&S®VSE-K104

Numéro de commande 1320.7568.06

Désignation

EUTRA/LTE TDD uplink and downlink measurement application

LTE signal analysis

R&S®VSE-K106

Numéro de commande 1320.7900.06

Désignation

EUTRA/LTE

Narrowband IoT analysis

R&S®VSE-K144

Numéro de commande 1309.9574.06

Désignation

5G NR uplink and downlink measurement application

R&S®VSE-K146

Numéro de commande 1345.1305.06

Désignation

5G MIMO measurements

R&S®VSE-K148

Numéro de commande 1345.1392.06

Désignation

5G NR R16 measurements

R&S®VSE-K149

Numéro de commande 1345.1463.06

Désignation

HRP UWB measurements

R&S®VSE-K171

Numéro de commande 1345.1663.02

Désignation

5G NR R17 measurements

R&S®VSE-K175

Numéro de commande 1350.7020.06

Désignation

O-RAN measurements

R&S®VSE-K201

Numéro de commande 1345.2001.06

Désignation

OneWeb reverse link measurement application for R&S®VSE software. This application can be used to analyze OneWeb SC-FDMA signals.

R&S®VSE-K544

Numéro de commande 1309.9580.06

Désignation

User-defined Frequency Correction by SnP File

R&S®VSE-SWM

Numéro de commande 1320.7622.81

Désignation

Software maintenance

General
Produit
Désignation
R&S®RTO6-Z1

Numéro de commande 1801.6641.02

Désignation

Front Cover: Protects the front of the R&S®RTO6 oscilloscope

R&S®RTO6-Z3

Numéro de commande 1801.6658.02

Désignation

Soft Case: Stores the R&S®RTO6 oscilloscope and accessories

R&S®RTO6-Z4

Numéro de commande 1801.6712.02

Désignation

Transit case: Protects the R&S®RTO6 oscilloscope and accessories during transport

R&S®ZZA-RTO6

Numéro de commande 1801.6729.02

Désignation

19" rackmount kit

Test fixtures
Produit
Désignation
R&S®RT-ZF1

Numéro de commande 1317.3420.02

Désignation

Test fixture set for USB2.0 compliance

Test fixture for USB 1.0/1.1/2.0 compliance tests. Supported by R&S®RTO-K21 USB compliance test option.

R&S®RT-ZF2

Numéro de commande 1317.5522.02

Désignation

Test fixture for 10/100/1000BASE-T, 10G-BaseT and BroadR-Reach Ethernet

Supported by R&S®RTO-K22, R&S®RTO-K23 and R&S®RTO-K24 Ethernet compliance test options.

R&S®RT-ZF3

Numéro de commande 5025.0670.02

Désignation

Frequency converter

for 100BASE-T1/BroadR-Reach compliance test

R&S®RT-ZF4

Numéro de commande 1333.0880.02

Désignation

10BASE-TE Energy Efficient Ethernet Test Fixture

R&S®RT-ZF5

Numéro de commande 1333.0896.02

Désignation

Ethernet Probing Fixture

(directional, link partner, load)

R&S®RT-ZF6

Numéro de commande 1337.8579.02

Désignation

Frequency converter board

for 1000BASE-T1 compliance test

R&S®RT-ZF7

Numéro de commande 1801.3688.02

Désignation

Automotive T&D Fixture

Automotive Ethernet probing fixture including 2 SMA adapters RT-ZF7A

R&S®RT-ZF7A

Numéro de commande 1801.4126.02

Désignation

SMA Adapter

High precision adapter board from automotive connector to SMA

R&S®RT-ZF7P

Numéro de commande 1802.9680.02

Désignation

SMA adapter for PoDL

High precision adapter board from Industrial Ethernet connectors to SMA

R&S®RT-ZF8

Numéro de commande 1801.3694.02

Désignation

Automotive Ethernet Compliance Fixture

Test fixture for 100BASE-T1 and 1000BASE-T1 compliance testing according to IEEE and OPEN TC8

R&S®RT-ZF2C

Numéro de commande 1317.5639.02

Désignation

1000BASE-T Jitter Test Cable

1000Base-T jitter test cable for the R&S®RTO-K22 Ethernet compliance test solution.

Numéro de commande 1800.0004.02

Désignation

Power deskew fixture

Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply

Passive probes
Produit
Désignation

Numéro de commande 1409.7550.00

Désignation

Passive probe, 500 MHz, 10:1

Passive broadband probes
Produit
Désignation

Numéro de commande 1409.7608.02

Désignation

Transmission line probe, 8 GHz, passive

Active single-ended probes
Produit
Désignation

Numéro de commande 1418.7007.02

Désignation

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4080.02

Désignation

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.3502.02

Désignation

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.4309.02

Désignation

Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1418.7307.02

Désignation

Active single-ended probe, 6 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Produit
Désignation

Numéro de commande 1410.4715.02

Désignation

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4409.02

Désignation

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4609.02

Désignation

Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.5205.02

Désignation

Active differential probe, 4.5 GHz, Rohde & Schwarz probe interface

Modular probe system
Produit
Désignation

Numéro de commande 1800.4700.02

Désignation

Modular probe amplifier module, 1.5 GHz

Numéro de commande 1419.3005.02

Désignation

Modular probe amplifier module, 3 GHz

Numéro de commande 1419.3105.02

Désignation

Modular probe amplifier module, 6 GHz

Numéro de commande 1419.3205.02

Désignation

Modular probe amplifier module, 9 GHz

Power rail probes
Produit
Désignation

Numéro de commande 1800.5006.02

Désignation

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

Numéro de commande 1800.5406.02

Désignation

Power rail probe, 4 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Multi-channel power probes
Produit
Désignation

Numéro de commande 1326.0259.02

Désignation

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs

Numéro de commande 1326.0259.04

Désignation

Multi-channel power probe

1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs

High voltage probes
Produit
Désignation

Numéro de commande 1333.0873.02

Désignation

250 MHz passive high voltage probe

Numéro de commande 1409.7720.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1409.7737.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1800.2107.02

Désignation

100 MHz High voltage differential probe

Numéro de commande 1800.2207.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2007.02

Désignation

100 MHz High voltage differential probe

Current probes
Produit
Désignation

Numéro de commande 1333.0850.02

Désignation

AC/DC 20 kHz current probe

Numéro de commande 1333.0844.02

Désignation

100 kHz current probe

Numéro de commande 1409.8204.02

Désignation

2 MHZ current probe

Numéro de commande 1409.7750K02

Désignation

10 MHZ current probe

Numéro de commande 1409.8210.02

Désignation

10 MHZ Current probe

Numéro de commande 1409.7766K02

Désignation

100 MHZ current probe

Numéro de commande 1409.8233.02

Désignation

100 MHZ current probe

Numéro de commande 1409.7772K02

Désignation

120 MHz current probe

Numéro de commande 1801.4932.02

Désignation

120 MHz current probe

EMC near field probes
Produit
Désignation

Numéro de commande 1147.2736.02

Désignation

E and H near-field probe set

R&S®RTO6 Mediacenter

CES: Ultra-Wideband Device Testing

janv. 31, 2022

Test de conformité Ethernet automobile 1000BASE-T1 avec Test Mode 4

déc. 28, 2021

Test d'interopérabilité 1000BASE-T1

déc. 22, 2021

La série R&S®RTO6 propose une nouvelle interface utilisateur pour des flux de travail simples

juil. 01, 2021

Faîtes vous une idée du R&S®RTO6

juil. 01, 2021

Application videos

Embedding & Equalization with the R&S RTP Oscilloscope (Part 1)

juil. 11, 2024

Embedding & Equalization with the R&S RTP Oscilloscope (Part 2)

juil. 10, 2024

Embedding & Equalization with the R&S RTP Oscilloscope (Part 3)

juil. 09, 2024

Embedding & Equalization with the R&S RTP Oscilloscope (Part 4)

juil. 08, 2024

PAM-N Analysis with the R&S RTP Oscilloscope (Part 1)

juin 28, 2024

PAM-N Analysis with the R&S RTP Oscilloscope (Part 2)

juin 27, 2024

PAM-N Analysis with the R&S RTP Oscilloscope (Part 3)

juin 26, 2024

O-RU energy efficiency testing

mars 12, 2024

Ce qui pourrait également vous intéresser

Premium content: Scopefield – A city with R&S®RTO6 applications

More information

Les 10 ans de Rohde & Schwarz en termes d'innovation dans le domaine des oscilloscopes

Plus d'information

Oscilloscopes promotion

Save up to 46% on fully equipped oscilloscopes. All options included from the start. Save now.

More information

Centre de webinaires dédié aux oscilloscopes pour les applications d'électronique de puissance et de conceptions numériques

Plus d'information

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.