Key Facts
- Bandwidth: 200 MHz to 2 GHz
- Sample rate: 5 Gsample/s
- Max. memory depth: 200 Msample
- Vertical resolution: up to 16-bit
- MSO: 16 digital channels, optional, retrofittable
Commençant à 5 730 EUR
Key Facts
Commençant à 5 730 EUR
R&S®RTE1000 oscilloscopes offer a fully integrated multi-domain test solution with time, frequency, protocol and logic analysis functions. From embedded design development to power electronics analysis to general debugging, the R&S®RTE1000 handles everyday T&M challenges quickly, accurately and easily.
Quick Links
See signal details with up to 16-bit vertical resolution in HD mode.
In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.
You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.
The mixed signal option turns the R&S®RTE1000 oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.
Numéro de commande 1326.2000.22
Numéro de commande 1326.2000.24
Numéro de commande 1326.2000.32
Numéro de commande 1326.2000.34
Numéro de commande 1326.2000.52
Numéro de commande 1326.2000.54
Numéro de commande 1326.2000.62
Numéro de commande 1326.2000.64
Numéro de commande 1326.2000.72
Numéro de commande 1326.2000.74
Numéro de commande 1326.2000.82
Numéro de commande 1326.2000.84
Vertical system | ||
Analog channels | R&S®RTE1022/R&S®RTE1032/ R&S®RTE1052/R&S®RTE1102/ R&S®RTE1152/R&S®RTE1202 | 2 |
Analog channels | R&S®RTE1024/R&S®RTE1034/ R&S®RTE1054/R&S®RTE1104/ R&S®RTE1154/R&S®RTE1204 | 4 |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTE1022/R&S®RTE1024 R&S®RTE1032/R&S®RTE1034 R&S®RTE1052/R&S®RTE1054 R&S®RTE1102/R&S®RTE1104 R&S®RTE1152/R&S®RTE1154 R&S®RTE1202/R&S®RTE1204 | ≥ 200 MHz ≥ 350 MHz ≥ 500 MHz ≥ 1 GHz ≥ 1.5 GHz ≥ 2 GHz |
Rise time | R&S®RTE1022/R&S®RTE1024 R&S®RTE1032/R&S®RTE1034 R&S®RTE1052/R&S®RTE1054 R&S®RTE1102/R&S®RTE1104 R&S®RTE1152/R&S®RTE1154 R&S®RTE1202/R&S®RTE1204 | < 1.75 ns < 1 ns < 700 ps < 350 ps < 233 ps < 175 ps |
Input impedance | 50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF ± 1 pF (meas.) | |
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 500 μV/div to 1 V/div 1 MΩ: 500 μV/div to 10 V/div |
ADC resolution | 8 bit | |
System ENOB | 7 bit | |
Acquisition system | ||
Realtime sampling rate | max. 5 Gsample/s on each channel | |
Acquisition memory | standard configuration, per channel/1 channel active | R&S®RTE1000 2-channel model: 10/20 Msample R&S®RTE1000 4-channel model: 10/40 Msample |
max. upgrade (R&S®RTE-B102 option), per channel/1 channel active | R&S®RTE1000 2-channel model: 50/100 Msample R&S®RTE1000 4-channel model: 50/200 Msample | |
Max. acquisition rate | > 1 000 000 waveforms/s | |
Decimation modes | any combination of decimation mode and waveform arithmetics | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Horizontal system | ||
Timebase range | 50 ps/div to 5000 s/div | |
Accuracy (after delivery/calibration) | ±2 ppm | |
Channel deskew | ±100 ns | |
Trigger system | ||
Standard Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video | |
Optional Trigger types | serial bus trigger | |
Trigger sensitivity | definition of trigger hysteresis | can be set automatically or manually from 0 div to 5 div |
Analysis and measurement functions | ||
Automatic measurements | 77 measurement functions | |
Cursor measurements | 2 cursor sets, each consisting of two horizontal and two vertical cursors | |
Waveform mathematics | 4 math waveforms; mathematics, logical operations, comparison, FIR filter, FFT | |
Mask testing | ||
Mask definition | advanced (user-configurable, hardware based) | |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO Memory depth | 100 Mpts per channel | |
MSO Bandwidth | 400 MHz | |
MSO Sampling rate | 5 Gsample/s per channel | |
MSO Input impedance | 100 k || 4 pF | |
Parallel buses | up to 4 | |
General data | ||
Dimensions | W x H x D | 427 mm × 249 mm × 204 mm (16.81 in × 9.8 in × 8.03 in) |
Weight | without options, nominal | 8,6 kg (18.96 lb) |
Display | 10.4' LC TFT color touchscreen, 1024 × 728 pixel (XGA) | |
Interfaces | 1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output | |
Operating system | Windows |
Numéro de commande 1326.3570.02
Mixed Signal Option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample per channel
Adds 16 digital channels to R&S®RTE1000 oscilloscopes.
Numéro de commande 1333.0750.02
Digital Extension Port for R&S®RTE
Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTE-B1
Numéro de commande 1326.3012.02
Arbitrary waveform generator
Add 2-channel 500 Msample/s waveform generator and 8-channel pattern generator
Numéro de commande 1317.4978.02
GPIB Interface
Numéro de commande 1317.7002.02
Replacement SSD, incl. firmware
SSD comes pre-installed with operating system and scope application
Numéro de commande 1326.1155.02
Memory upgrade to 20 Msample
Memory upgrade to 20 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
Numéro de commande 1326.1161.02
Memory upgrade to 50 Msample
Memory upgrade to 50 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
Numéro de commande 1326.1384.02
Bandwidth upgrade of the R&S®RTE1022/4 to 350 MHz bandwidth, incl. calibration
Numéro de commande 1326.1390.02
Bandwidth upgrade of the R&S®RTE1022/4 to 500 MHz bandwidth, incl. calibration
Numéro de commande 1326.1403.02
Bandwidth upgrade of the R&S®RTE1022/4 to 1 GHz bandwidth, incl. calibration
Numéro de commande 1326.1410.02
Bandwidth upgrade of the R&S®RTE1022/4 to 1.5 GHz bandwidth, incl. calibration
Numéro de commande 1326.1426.02
Bandwidth upgrade of the R&S®RTE1022/4 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1326.1432.02
Bandwidth upgrade of the R&S®RTE1032/4 to 500 MHz bandwidth, incl. calibration
Numéro de commande 1326.1449.02
Bandwidth upgrade of the R&S®RTE1032/4 to 1 GHz bandwidth, incl. calibration
Numéro de commande 1326.1455.02
Bandwidth upgrade of the R&S®RTE1032/4 to 1.5 GHz bandwidth, incl. calibration
Numéro de commande 1326.1461.02
Bandwidth upgrade of the R&S®RTE1032/4 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1326.1478.02
Bandwidth upgrade of the R&S®RTE1052/4 to 1 GHz bandwidth, incl. calibration
Numéro de commande 1326.1484.02
Bandwidth upgrade of the R&S®RTE1052/4 to 1.5 GHz bandwidth, incl. calibration
Numéro de commande 1326.1490.02
Bandwidth upgrade of the R&S®RTE1052/4 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1326.1503.02
Bandwidth upgrade of the R&S®RTE1102/4 to 1.5 GHz bandwidth, incl. calibration
Numéro de commande 1326.1510.02
Bandwidth upgrade of the R&S®RTE1102/4 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1326.1526.02
Bandwidth upgrade of the R&S®RTE1152/4 to 2 GHz bandwidth, incl. calibration
Numéro de commande 1326.1178.02
I²C/SPI triggering and decoding
Numéro de commande 1326.1184.02
UART/RS-232 triggering and decoding
Numéro de commande 1326.1190.02
CAN/LIN triggering and decoding
Numéro de commande 1326.1203.02
FlexRay™ triggering and decoding
Numéro de commande 1326.1210.02
I²S/LJ/RJ/TDM triggering and decoding
Numéro de commande 1326.1226.02
MIL-1553 triggering and decoding
Numéro de commande 1326.1232.02
ARINC 429 triggering and decoding
Numéro de commande 1326.1332.02
Ethernet serial decoding
Numéro de commande 1326.1249.02
CAN-FD triggering and decoding
Numéro de commande 1326.1603.02
SENT triggering and decoding
Numéro de commande 1801.2852.02
Bus analysis
Numéro de commande 1326.1326.02
MANCHESTER/NRZ triggering and decoding
Numéro de commande 1326.1255.02
MDIO triggering and decoding
Numéro de commande 1333.0615.02
100BASE-T1 triggering and decoding
Numéro de commande 1326.1610.02
USB 1.0/1.1/2.0/HSIC triggering and decoding
Numéro de commande 1326.3158.02
USB-PD triggering and decoding
Numéro de commande 1326.2845.02
SpaceWire triggering and decoding
Numéro de commande 1326.3193.02
CXPI triggering and decoding
Numéro de commande 1326.1261.02
High definition mode
Numéro de commande 1326.3006.02
Spectrum analysis
Numéro de commande 1326.1278.02
Power analysis
Numéro de commande 1802.9296.02
Upgrade to Windows 10 (includes new PC and Windows 10 license)
Numéro de commande 1802.9338.02
Upgrade to Windows 10 (includes new PC, new SSD and Windows 10 license)
Numéro de commande 1333.0096.02
Front Cover
Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope
Numéro de commande 1304.9118.02
Soft Case
Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories
Numéro de commande 1317.7025.02
Transit case
Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport
Numéro de commande 1317.7031.02
Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes
Numéro de commande 1304.8286.00
19" Rackmount Adapter
For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 19" rack with 6U heigth
Numéro de commande 1338.0007.02
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Numéro de commande 1409.7550.00
Passive probe, 500 MHz, 10:1
Numéro de commande 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4309.02
Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4609.02
Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1800.4700.02
Modular probe amplifier module, 1.5 GHz
Numéro de commande 1419.3005.02
Modular probe amplifier module, 3 GHz
Numéro de commande 1419.4301.02
Solder-in probe tip cable for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Numéro de commande 1801.4349.02
Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system
>16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Numéro de commande 1419.4318.02
Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Numéro de commande 1419.4324.02
Square-pin probe tip module for R&S®RT-ZM modular probe system
> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM
Numéro de commande 1419.4224.02
Quick connect probe tip module for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
Numéro de commande 1419.4353.02
Browser module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, DM
Numéro de commande 1419.4201.02
SMA module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Numéro de commande 1419.4218.02
Temperature kit for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
Numéro de commande 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Numéro de commande 1326.0259.02
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs
Numéro de commande 1326.0259.04
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs
Numéro de commande 1333.0873.02
250 MHz passive high voltage probe
Numéro de commande 1409.7720.02
400 MHz passive high voltage probe
Numéro de commande 1409.7737.02
400 MHz passive high voltage probe
Numéro de commande 1422.0703.02
100 MHZ high voltage differential probe
Numéro de commande 1333.0821.02
Active differential probe, 200 MHz, BNC interface
Numéro de commande 1333.0838.02
Active differential probe, 800 GHz, BNC interface
Numéro de commande 1800.2107.02
100 MHz High voltage differential probe
Numéro de commande 1800.2207.02
200 MHz High voltage differential probe
Numéro de commande 1800.2007.02
100 MHz High voltage differential probe
Numéro de commande 1337.9700.02
25 MHz High voltage differential probe
Numéro de commande 1337.9800.02
25 MHz High voltage differential probe
Numéro de commande 1333.0850.02
AC/DC 20 kHz current probe
Numéro de commande 1333.0844.02
100 kHz current probe
Numéro de commande 1409.8204.02
2 MHZ current probe
Numéro de commande 1409.7750K02
10 MHZ current probe
Numéro de commande 1409.8210.02
10 MHZ Current probe
Numéro de commande 1409.8227.02
50 MHZ Current probe
Numéro de commande 1409.7766K02
100 MHZ current probe
Numéro de commande 1409.8233.02
100 MHZ current probe
Numéro de commande 1409.7772K02
120 MHz current probe
Numéro de commande 1801.4932.02
120 MHz current probe
Numéro de commande 1147.2736.02
E and H near-field probe set
Numéro de commande 1326.4190.02
Trigger and decode bundle option
Decode more than 28 serial protocols with the R&S®RTE trigger and decode software bundle. T&D bundle includes I2C/SPI, UART/RS232, CAN/LIN, FlexRay, I2S, MIL, ARINC, Ethernet, CAN-FD, SENT, Custom, MDIO, USB2.0, USB-PD, SpaceWire, CXPI
Produits associés
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz
1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").
2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.
3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.
4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.
5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :
Prix : 1x oscilloscope numérique R&S®RTB2000
6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.
7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.
8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.
9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.
10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.
11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.
12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.
13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.