Key Facts

  • Addresses high-speed probing challenges
  • Flexible and configurable connectivity
  • MultiMode functionality for switching between measurement modes
  • Integrated high precision voltmeter
  • Integrated micro button for convenient instrument control

Brief description

The R&S®RT-ZM modular probe system addresses today’s probing requirements with a technically sophisticated, yet easy-to-handle solution. The various probing solutions meet the demands for high probing bandwidth and dynamic range in conjunction with the need for low capacitive load. The R&S®RT-ZM probe system includes probe tip modules for various measurement tasks and conditions. The probe tip modules can be connected to amplifier modules with bandwidths ranging from 1.5 GHz to 16 GHz.

Features & benefits

Flexible & Configurable

The R&S®RT-ZM modular probe system delivers high performance in combination with flexible and configurable connectivity. The R&S®RT-ZM probe system includes probe tip modules for various measurement tasks and conditions.

Block diagram of modular probe system
Ingrandisci immagine

Block diagram of modular probe system

Easy switching between measurement modes

The multimode functionality allows users to switch between single-ended, differential and common mode measurements without reconnecting or resoldering the probe tip. The multimode functionality is implemented on the company-designed, high-speed R&S®RT-ZM amplifier ASIC.

Multimode measurement of a differential signal
Ingrandisci immagine

Multimode measurement of a differential signal

Offset compensation for maximum resolution

The R&S®RT-ZM modular probe system offers a unique offset compensation range of ±16 V. The DC components of a measured signal can be compensated at the probe tip, upstream of the differential R&S®RT-ZM amplifier ASIC. The benefit of this approach is that the operating voltage window is extended beyond the dynamic range of the probe amplifier module and the signal components of interest can be displayed on the oscilloscope with maximum resolution. The feature is also available in multimode operation.

DC offset compensation for multimode measurements
Ingrandisci immagine

DC offset compensation for multimode measurements

High precision DC voltage measurement

The integrated and unique R&S®ProbeMeter operates independently from the oscilloscope and measures the DC component of a signal with an accuracy of 0.05 %. The DC measurement is performed continuously and in parallel with the waveform aquisition of the oscilloscope. The high precision is achieved through immediate digitization of the measured DC voltage with a dedicated ADC inside the R&S®RT-ZM probe amplifier module.

Probe meter reading
Ingrandisci immagine

Probe meter reading

Instrument control at the tip of the probe

The R&S®RT-ZM probe amplifier module comes with an integrated micro button that allows users to stay focused on their measurement tasks and conveniently operate their oscilloscopes. The micro button can be configured on Rohde & Schwarz oscilloscopes to perform a variety of functions, such as run/stop, auto set, save waveform, find trigger level, and create automated test report. Multimode switching can also be configured for the R&S®RT-ZM modular probe system.

List of selectable micro button actions
Ingrandisci immagine

List of selectable micro button actions

Available models

Available models
Modelli
Bandwidth
Rise time
Probe AMP/TIP module

R&S®RT-ZM15

Order Number 1800.4700.02

Bandwidth
> 1.5 GHz
Rise time
< 230 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 1.5 GHz

R&S®RT-ZM30

Order Number 1419.3005.02

Bandwidth
> 3 GHz
Rise time
< 100 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 3 GHz

R&S®RT-ZM60

Order Number 1419.3105.02

Bandwidth
> 6 GHz
Rise time
< 75 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 6 GHz

R&S®RT-ZM90

Order Number 1419.3205.02

Bandwidth
> 9 GHz
Rise time
< 50 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 9 GHz

R&S®RT-ZM130

Order Number 1800.4500.02

Bandwidth
> 13 GHz
Rise time
< 35 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 13 GHz

R&S®RT-ZM160

Order Number 1800.4600.02

Bandwidth
> 16 GHz
Rise time
< 28 ps
Probe AMP/TIP module
Probe amplifier module
Realtime bandwidth > 16 GHz

Available options

Probe tips
Product
Descrizione
R&S®RT-ZMA10

Order Number 1419.4301.02

Descrizione

Solder-in probe tip cable for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA10-6

Order Number 1801.4349.02

Descrizione

Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system

>16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA11

Order Number 1419.4318.02

Descrizione

Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA12

Order Number 1419.4324.02

Descrizione

Square-pin probe tip module for R&S®RT-ZM modular probe system

> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA14

Order Number 1338.1010.02

Descrizione

Flex connect solder-in probe tip module for R&S®RT-ZM modular probe system

>16 GHz, <28 ps, probe tip module, P/N/DM/CM, incl. 10 solder-in flex connect tips

R&S®RT-ZMA15

Order Number 1419.4224.02

Descrizione

Quick connect probe tip module for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA30

Order Number 1419.4353.02

Descrizione

Browser module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, DM

R&S®RT-ZMA40

Order Number 1419.4201.02

Descrizione

SMA module for R&S®RT-ZM modular probe system

> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM

R&S®RT-ZMA50

Order Number 1419.4218.02

Descrizione

Temperature kit for R&S®RT-ZM modular probe system

> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM

Probe accessories
Product
Descrizione
R&S®RT-ZMA1

Order Number 1419.3911.02

Descrizione

Storage case for up to 6 R&S®RT-ZMA1x tip cables

R&S®RT-ZM-ACA

Order Number 1419.3928.02

Descrizione

Calibration in line with ISO 17025 and ISO 9000

DAkkS (formerly DKD) calibration in line with ISO 17025 and ISO 9000 for R&S®RT-ZMxx modular probe amplifier (order only with device)

Order Number 1326.3641.02

Descrizione

3D probe positioner

3D positionier with central tensioning knob for easy clamping and positioning of probes (span width: 200 mm, clamping range: 15 mm)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.