R&S®ZN-ZE1xx network analyzer calibration units

Automatic calibration units with two configurable ports

R&S®ZN-ZE1xx network analyzer calibration units
Open Lightbox
R&S®ZN-ZE1xx network analyzer calibration units
Open Lightbox
R&S®ZN-ZE1xx network analyzer calibration units
Open Lightbox
R&S®ZN-ZE1xx network analyzer calibration units
Open Lightbox
R&S®ZN-ZE1xx network analyzer calibration units
Open Lightbox
R&S®ZN-ZE1xx, front view R&S®ZN-ZE1xx, front view R&S®ZN-ZE1xx, front view R&S®ZN-ZE1xx, front view R&S®ZN-ZE1xx, front view

Key Facts

  • Frequency range from 5 kHz to 26.5 GHz
  • Port connectors configurable as 3.5 mm-compatible (m/f) or N-type (m/f)
  • Lightweight, rugged, portable

Economy calibration unit with a flexible configuration concept

R&S®ZN-ZE1xx calibration units combine the efficiency of automatic calibration procedures with a great price/performance ratio, and also offer the flexibility of configuring ports as needed. All models support 3.5 mm-compatible connectors, and the R&S®ZN-ZE104, R&S®ZN-ZE109 and R&S®ZN-ZE118 support N-type connectors as well. Once a connector type is chosen, each individual port can be further configured as male (m) or female (f)

Caractéristiques & avantages

Lowest start frequency

Frequency ranges starting from 5 kHz

With a start frequency of 5 kHZ to 26.5 GHz, the R&S®ZN-ZE1xx perfectly supports the full frequency range of the R&S®ZND, R&S®ZNL, R&S®ZNLE and R&S®ZNH. The R&S®ZNA, R&S®ZNB and R&S®ZNBT are also supported.

Calibrate all port counts with each unit

Calibrate n-ports with a 2-port calibration unit

Calibrating more ports than offered by the R&S®ZN-ZE1xx is easy. A step-by-step guide helps users calibrate every port number with a two-port calibration unit, resulting in full n-port calibration.

Configurable test port types

Support for two connector system types

The ports on every R&S®ZN-ZE1xx model can be configured as 3.5 mm-compatible or N-type (not available for the R&S®ZN-ZE126). Each port can also be individually configured as male (m) or female (f).

Auto configuration and detection

Plug & play calibration

R&S®ZN-ZE1xx calibration units are automatically detected via the USB connection. All required data is transferred to the VNA. When starting calibration, connected test cables and port assignments can be found at the press of a button. Calibration requires minimal effort and time and maximum reliability.

Available models

Available models
Modèles
Type
Frequency range
Connector type
Number of ports
Description

R&S®ZN-ZE104

Numéro de commande 1350.8040.04

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 4.5 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE109

Numéro de commande 1350.8040.09

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 9 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE118

Numéro de commande 1350.8040.18

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 18 GHz
Connector type
N (m/f) or 3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

R&S®ZN-ZE126

Numéro de commande 1350.8040.26

Type
Calibration unit 50 Ohms
Frequency range
5 kHz to 26.5 GHz
Connector type
3.5mm-compatible (m/f)
Number of ports
2
Description
for R&S®ZNA, ZNB/T, ZND, ZNL, ZNLE, ZNH

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.