Hauptmerkmale

  • Max. output power: 100 W
  • Max. voltage per channel: 32 V
  • Max. current per channel: 3 A, 5 A or 10 A
  • Galvanically isolated, floating and short-circuit proof outputs
  • Intuitive, price-transparent online product configurator

ab 1.180 EUR

  • R&S®Essentials

Compact and easy to use

R&S®NGC100 DC power supplies are very energy efficient, remaining cool and quiet, even at maximum load. Practical interfaces and connectors make work quick and convenient while special applications have comfort functions. One, two, or three channels – a wide range of functions and fundamental specifications make R&S®NGC100 DC power supplies ideal for:
-Development labs
-Industrial environments
-Manufacturing
-Education
You can now use the new online configurator to quickly design your R&S®NGC100 DC power supply with full price transparency. Get your request processed in no time by the authorized distribution partner of your choice.

Merkmale & Vorteile

Maximum output power at various operating points

With FlexPower

Get maximum power at various operating points. Unlike single-range power supplies, variable voltage and current combinations can be generated within an overall power limit.

Emulate real-world scenarios

With EasyArb 

Generate complex time varying output voltage or current sequences with the EasyArb function to emulate normal power subsystem behavior early in the design process or simulate power problems for DUT design verification. The EasyArb function lets you generate time varying output voltage and current sequences with dwell times down to 10 ms.

Log measurement values

Every millisecond

Logging data is vital to long-term monitoring, reviewing test setups and repeating test conditions to analyze power behavior or optimize power consumption. R&S®NGC100 power supplies simultaneously log voltage and current measurements over time on all outputs with a maximum acquisition rate of 1000 samples/s. Easily export the time stamped data as a CSV file for analysis, reports and documentation.

Higher current and voltage levels

With parallel and serial operation

Each output in the 2-channel and 3-channel models is completely isolated for maximum flexibility. Use the channels independently or combine them in series to increase the maximum voltage to 96 V, or in parallel for up to 10 A of current. The full galvanic isolation means that channels can be connected to supply balanced circuits without any need to think about grounding.

Up to 96 V with the R&S®NGC103 power supply
Lightbox öffnen

Up to 96 V with the R&S®NGC103 power supply

Control inrush current

With EasyRamp

Some test setups require a continuous rise in supply voltage instead of a rapid jump to control inrush currents. Increase output voltage continuously within 10 ms to 10 s with the EasyRamp function.

Create power up sequences

With output delay

Turn on each channel individually with a delay to meet requirements for modern micro controllers with multiple supply voltage levels and demand-specific power up sequences.

Compensate voltage drops

Using remote sensing

Improve voltage regulation and measurement accuracy with remote sensing. Regulate output voltage directly at the DUT input terminals instead of the power supply. The sense function compensates for voltage drops in supply leads, especially in applications with high current levels. R&S®NGC100 power supplies provide sense connections for each output.

Using remote sensing to compensate for load lead voltage drops
Lightbox öffnen

Using remote sensing to compensate for load lead voltage drops

Start instrument functions

With an external trigger

An external trigger signal (TTL) to the voltage interface on the back panel of the instrument can start an arbitrary function, activate and deactivate output delays or activate data logging.
 

Direct control of output voltage

With the analog control interface

Directly and quickly control output voltage. External analog voltage from 0 V to 10 V or current from 4 mA to 20 mA can control any or all outputs with input scaling of 0 to 100%. Galvanic isolation between the control voltage and the outputs simplifies connections while maintaining user safety even in floating circuit applications.

Verfügbare Modelle

Verfügbare Modelle
Modelle
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Startpreis

R&S®NGC101

Bestellnummer 3657.2288.02

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Startpreis
1.180 EUR

R&S®NGC101-G

Bestellnummer 3657.2288.03

Number of output channels
1
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
10 A
Startpreis
1.630 EUR

R&S®NGC102

Bestellnummer 3657.2359.02

Number of output channels
2
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
5 A
Startpreis
1.320 EUR

R&S®NGC103

Bestellnummer 3657.2413.02

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 A
Output current per channel
3 A
Startpreis
1.460 EUR

R&S®NGC103-G

Bestellnummer 3657.2413.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
32 V
Output current per channel
3 A
Startpreis
1.910 EUR
Technische Daten
Electrical specifications
Number of output channels 1 / 2 / 3
Total output power max. 100 W
Maximum output power per channel 100 W/50 W/33 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 10 A/5 A/3 A
Voltage ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1 mV (RMS)
R&S®NGC102/103: < 450 µV (RMS)
Current ripple and noise (20 Hz to 20 MHz) R&S®NGC101: < 1.5 mA (RMS) (meas.)
R&S®NGC102/103: < 1 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 1 ms (meas.)
Programming resolution voltage 1 mV
Programming resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
≥ 1 A: 1 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current < 1 A: 0.1 mA (R&S®NGC101: 0.5 mA)
 ≥ 1 A: 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 2 mV
Readback accuracy current ±(% of output + offset) typ. < 0.05 % + 4 mA (R&S®NGC101: typ. < 0.15 % + 10 mA)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode -
Output sequencing
External trigger
Arbitrary function ● (EasyArb)
Analog/modulation interface
Data logging
Display and interfaces
Display 3.5" QVGA
Rear panel connections Connector block with 4 lines per channel
Remote control interfaces: standard USB, LAN; R&S®NGC100-G models with IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 222 mm × 97 mm × 291 mm
Weight 2.6 kg
Rack installation R&S®HZC95 option

Verfügbare Optionen

Rack adapter
Produkt
Beschreibung
R&S®HZC95

Bestellnummer 5800.2054.02

Beschreibung

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing-Einverständniserklärung

Ihre Anfrage wurde erfolgreich versendet. Wir nehmen in Kürze Kontakt mit Ihnen auf.
An error is occurred, please try it again later.
Allgemeine Informationen und rechtliche Hinweise

Unverbindliche Preisempfehlung des Herstellers (UVP). Der dargestellte Preis versteht sich ohne USt. Preise und Angebote richten sich nur an Unternehmer und nicht an private Verbraucher.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Teilnahmebedingungen für das Gewinnspiel „10 Jahre Oszilloskope von Rohde & Schwarz“

1. Das Gewinnspiel „10 Jahre Oszilloskope von Rohde & Schwarz“ (nachfolgend „Gewinnspiel“ genannt) wird organisiert von der Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 München, Deutschland, Tel. +49 89 41 29 0 (nachfolgend „R&S“ genannt).

2. Teilnehmer können sich zwischen dem 1. Januar 2020 und dem 31. Dezember 2020 mit ihrem Namen, Firmennamen und ihrer geschäftlichen E-Mailadresse registrieren.

3. Die Teilnahme am Gewinnspiel ist kostenlos und nicht vom Erwerb einer Ware oder Dienstleistung abhängig.

4. Teilnahme- und gewinnberechtigt sind nur juristische Personen. Natürlichen Personen ist es nicht gestattet, in ihrem eigenen Namen und auf eigene Rechnung teilzunehmen. Sie dürfen das Teilnahmeformular lediglich in ihrer Eigenschaft als Vertreter einer juristischen Person und im Namen und Auftrag dieser juristischen Person einreichen.

5. Zu gewinnen gibt es innerhalb des Zeitraums vom 1. Januar 2020 bis zum 31. Dezember 2020 jeweils eines von zehn R&S®RTB2000 Oszilloskopen:

Preis: 1x R&S®RTB2000 Digitales Oszilloskop

6. Die Preisverlosung findet am Hauptsitz von Rohde & Schwarz, Mühldorfstraße 15, 81671 München, statt. Die Gewinner werden innerhalb von fünf (5) Werktagen per E-Mail benachrichtigt.

7. Der bevollmächtigte Vertreter der juristischen Person hat die Inanspruchnahme des Gewinns gegenüber R&S zu bestätigen. Bleibt diese Inanspruchnahme aus oder erfolgt keine Antwort innerhalb von zwei (2) Wochen, wird ein neuer Gewinner ermittelt. Wenn innerhalb von vier (4) Wochen kein Gewinner feststeht, endet die Verlosung und der Preis verfällt.

8. Mitarbeiter von R&S und an der Konzeption und Umsetzung des Gewinnspiels beteiligte Personen sowie ihre Familienmitglieder sind nicht berechtigt, das Teilnahmeformular auszufüllen.

9. Eine Barauszahlung oder ein Umtausch von Preisen ist ausgeschlossen. Preise sind nicht übertragbar. Alle Steuern, Abgaben, Zölle, Gebühren und sonstigen Entgelte, die im Land des Teilnehmers erhoben werden, sind vom Teilnehmer zu tragen.

10. Personenbezogenen Daten werden ausschließlich für die Durchführung des Gewinnspiels verwendet und innerhalb von vier (4) Wochen nach Ende des Gewinnspiels gelöscht, sofern nichts anderes vereinbart wurde.

11. Ein Verstoß gegen diese Teilnahmebedingungen berechtigt R&S, den jeweiligen Teilnehmer von der Teilnahme auszuschließen. Handelt es sich bei dem ausgeschlossenen Teilnehmer um einen bereits ausgelosten Gewinner, kann der Gewinn nachträglich aberkannt werden. Wird ein Preis aufgrund eines Verstoßes gegen diese Teilnahmebedingungen nachträglich aberkannt, ist er von dem jeweiligen Teilnehmer auf dessen Kosten an die oben unter Punkt 1 angegebene Anschrift von R&S zurückzusenden, und es wird ein neuer Gewinner ermittelt.

12. Teilnehmer haben keinen Gewinnanspruch. Der Rechtsweg ist ausgeschlossen.

13. Das Gewinnspiel und jedes daraus zwischen R&S und dem jeweiligen Teilnehmer entstehende Vertragsverhältnis unterliegt deutschem Recht und gilt unter Ausschluss kollisionsrechtlicher Regelungen. Für alle Streitigkeiten, die sich mittelbar oder unmittelbar aus der Teilnahme an diesem Gewinnspiel ergeben, wird München als ausschließlicher Gerichtsstand vereinbart.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.