Analog TV |
Number of R&S®VH8600A1 amplifiers |
2 |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
16 |
20 |
Output power (sync peak) 1) |
3.5 kW |
5.1 kW |
7.0 kW |
8.5 kW |
10 kW |
13.3 kW |
16.3 kW |
19.5 kW |
25.6 kW |
31.4 kW |
RF output |
EIA 1 5/8" |
EIA 3 1/8" |
EIA 4 1/2" |
Dimensions (H × W × D) |
2000 mm × 600 mm × 1100 mm (78.7 in × 23.6 in × 43.3 in) |
2000 mm × 1200 mm × 1100 mm (78.7 in × 47.2 in × 43.3 in) |
1) After four-cavity bandpass filter; other output powers on request.
Specifications |
Analog TV
|
TV standards |
|
B/G, D/K, M, M1, N, I, I1 |
Color transmission |
|
PAL, NTSC, SECAM |
Sound transmission |
|
dual-sound coding in line with IRT or FM single sound and NICAM728 (−13 dB/−20 dB) or FM single sound (−10 dB) |
Inputs |
|
2 × video (BNC, 75 Ω), 2 × audio (XLR, 3-contact) |
General data
|
Frequency range |
UHF bands IV/V |
470 MHz to 862 MHz |
Power supply |
with three-phase amplifiers (standard) |
3 × 400 V ± 15 % 1), 47 Hz to 63 Hz |
|
with single-phase amplifiers (optional, for R&S®NV8602 to R&S®NV8610) |
3 × 208 V – 10 %/+ 15 % 1) or 240 V – 15 %/+ 10 % 2) 47 Hz to 63 Hz |
Max. installation altitude |
|
2000 m above sea level (> 2000 m on request) |
Operating temperature range |
|
+1 °C to +45 °C |
Relative humidity (max.) |
|
95 %, non-condensing |
Immunity
3)
|
to fast transients and burst in line with IEC 61000-4-4 |
< 4 kV (AC supply), < 1 kV (signal inputs) |
|
to surges in line with IEC 61000-4-5 |
balanced < 2 kV (e.g. L1-L2) unbalanced < 4 kV (e.g. L1-N) |
Synchronization
|
Reference frequency |
|
10 MHz, 0.1 V to 5 V (Vpp) or TTL, BNC |
Reference pulse |
|
1 Hz, TTL, BNC |
Operation
|
Display, keypad and status LEDs |
|
local operation and display |
Ethernet interface, RJ-45 |
|
convenient operation, local or remote, via standard web browser |
|
optional |
network management interface via SNMP |
Parallel remote-control interface |
optional |
floating contacts for messages and commands |
1) To be connected to an AC supply network with Y, 3w + N + PE.
2) To be connected to an AC supply network with 120/240 V, 2w + N + PE.
3) With integrated AC supply overvoltage protection; more stringent requirements must be covered by additional on-site measures.
To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.