Search

Find relevant information on products, solutions or downloads quickly by using our general search: Type in a keyword, choose a category and select from the active subcategories to get what you need.

Results 1 - 10 of 72 nrpz211

Did you find what you're looking for? If not, repeat the search on our International Website

  • R&S®NRP-Z211 Two-Path diode power sensors

    Brief descriptionThe R&S®NRP-Z211 two-path diode power sensors combine all key characteristics relevant for their use in production: They are cost-effective, fast, precise and USB-capable.

  • Power Meter & Voltmeter - Test & Measurement

    Power sensors, power meters, directional power meters and voltmetersPower meters, power sensors and volt meters from Rohde & Schwarz stand for highest measurement accuracy and reliability – and have done so for decades.Rohde & Schwarz power sensors are intelligent standalone instruments with a flexible connection concept. The comprehensive USB-capable sensor portfolio is designed to operate with the

  • Software for R&S®NRP-Z211 Two-Path diode power sensors

    Title Size Version Date NRPZ Sanitizer Release Notes 590 kB2.17.3 30.08.2018 Title Size Version Date R&S®NRPV Virtual Power Meter 3.2 Release Notes 458 kB3.2 04.10.2017 R&S®Power Viewer for MacOS 18 MB01/2019 03.01.2019 R&S®Power Viewer - Open Source Acknowledgement 214 kB04 09.07.2018 R&S®NRP-Toolkit for MacOS 407 kB01/2019 03.01.2019 R&S®Power Viewer - Release Notes 182 kB11.3 04.11.2019 R&S®NRP-Toolkit

  • Firmware for R&S®NRP-Z211 Two-Path diode power sensors

    Title Versions Last Modified File Size R&S®NRP-Z11/-Z21/-Z22/-Z23/-Z24 - Firmware Version 4.16 (Please read the Release Notes carefully before you install the firmware on your instrument) V 4.16 02.02.2012608 kB R&S®NRP-Z11/-Z21/-Z22/-Z23/-Z24 - Release Notes Version 4.16 V 4.16 02.02.2012 370 kB R&S®NRP-Z28/-Z98 - Firmware Version 4.08a (Please read the Release Notes carefully before you install the

  • Drivers for R&S®NRP-Z211 Two-Path diode power sensors

    File DescriptionDateRelated Content 26.09.2017 Driver rsnrpz history 31.07.2018 How to use the R&S®NRP-Z Instrument Drivers 01.08.2018 Driver NameSizeVersionDateVXIplug&play x86 driver rsnrpz This driver packet is already included in NRP-Toolkit2 MB3.6.0.0 19.11.2018 LabVIEW 2010 x64 Windows driver rsnrpz 18 MB3.6.0.0 19.09.2018 LabVIEW 2010 x86 Windows driver rsnrpz 18 MB3.6.0.0 19.09.2018 LabWindows

  • R&S®NRP-Z211/-Z221 Two-Path Diode Power Sensor - Fact Sheet

    Get accurate results faster

  • R&S®NRP-Zxx Power Sensors - Specifications

    The most important features for accurate and uncomplicated power measurements are top measurement accuracy and speed as well as simple operation on a base unit or a laptop/PC. The R&S®NRP power meter family combines all these characteristics in the R&S®NRX base unit, R&S®NRPV virtual power meter PC software and a comprehensive portfolio of LAN and USB power sensors. The R&S®NRP family is ideal for use in production, R&D and calibration labs as well as for installation and maintenance tasks.

  • Hints for Fast and Accurate Testing of GSM/EDGE Mobile Phone Power Amplifiers

    Short measurement time in conjunction with high accuracy and repeatability of results are essential for efficient testing of mobile phone power amplifiers. Power Meter R&S®NRP, Signal Generator R&S®SMIQ, Spectrum Analyzers R&S®FSP/FSU/FSQ and Power Supply R&S®NGMO2 offer optimum characteristics such as high accuracy, fast settling speed and short measurement time in programmed mode. This application note concentrates on testing GSM/EDGE mobile power amplifiers and shows typical test setups and programming examples for Signal Generator R&S®SMIQ and Spectrum Analyzer R&S®FSP/FSU/FSQ, benchmark numbers and repeatability results.

  • Fast Scalar Network Analysis Using a Signal Generator and a Power Meter

    This document presents a simple procedure for network analysis that is more cost-effective than the use of scalar network analyzers. It allows the accurate measurement of the transmission characteristics of filters, amplifiers and frequency converters over a large frequency and dynamic range. In order to reach very high measurement speeds, Rohde & Schwarz signal generators are operated in 'List Mode', and Rohde & Schwarz power meters are operated in 'Buffered Mode.' The required programming for the signal gene­rator and the power meter is illustrated by excerpts from a Visual Basic program which is available, free of charge, upon request.

  • CDMA2000® Base Station Test with R&S Equipment

    This Application Note describes measurements compliant with the cdma2000® base station standard described in 3GPP2 C.S0010 / TIA/EIA-97 / ARIB STD-T64-C.S0010. The primary focus is on solutions for generating and analyzing cdma2000® signals. The special characteristics that make the selected signal generators and signal analyzers eminently suitable for this purpose are detailed, and remote control programming is demonstrated by a free of charge program.

Results 1 - 10 of 72
Previous  1  2  3  4  5  6  7  8  Next
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Download

Please enter your first name.

Please enter a valid email address.

Please enter your name.

Please enter your company name.

Please enter your location.

Marketing permission
Please enter the characters shown in the image
show captcha

The input was not correct.
Content types Download types
International Website