BPFC Bandpass filters

BPFC Bandpass filters
Abrir o Lightbox
BPFC Bandpass filters
Abrir o Lightbox
BPFC Bandpass filters
Abrir o Lightbox
BPFC Bandpass filters, Side view BPFC Bandpass filters, Side view BPFC Bandpass filters, Side view

Key Facts

  • 700/800/850/900/1800/1900/2100/2600 MHz BPFC UL bandpass filters
  • Rejection: ≥ 20 dB in specified frequencies
  • Return loss: ≥ 15 dB
  • Insertion loss: ≤ 1.5 dB
  • Continuous average power: ≤ 1 W (peak: ≤ 10 W)

Ideal for interference hunting

High-power signals transmitted by base stations might saturate the test equipment. The CCI bandpass filters eliminate this effect by blocking unwanted signals outside of the frequency range of interest and enabling a clear visualization of the signals present in the uplink range.

The bandpass filters consist of multiple cavity resonators to provide optimal performance for the passband with low insertion loss, low intermodulation and high power handling. The small form factor and low weight make the filters ideal for measurements in the field. 

Features & benefits

Focus on the signal you are looking for

Uplink signals are more susceptible to interference. During measurements performed close to a base station, high power downlink signals may interfere in the uplink frequency range.

A bandpass filter keeps the influence of downlink signals away, allowing you to analyze the uplink frequency range and spot the presence of interferers more easily and quickly.

Measurement results from a 900 MHz GSM network
Abrir o Lightbox

Measurement results from a 900 MHz GSM network

The bandpass filter eliminates the influence of BTS signals and enables the easy identification of an interferer in the network.

Optimal performance

The BPFC bandpass filter from CCI provides optimal performance for the passband with low insertion loss and low intermodulation. Excellent return loss delivers the best match to the antennas and base station.

The bandpass filter consists of multiple cavity resonators to achieve 20 dB of rejection within the specified frequencies. Extensive temperature compensation is employed to insure frequency stability over the specified temperature range.

 BPFC bandpass filters
Abrir o Lightbox

BPFC bandpass filters

Available models

Available models
Modelos
Rejection ≥ 20 dB
Start frequency (MHz)
Stop frequency (MHz)
Rejection ≥ 20 dB)

BPFC-0700

Rejection ≥ 20 dB
693
Start frequency (MHz)
703
Stop frequency (MHz)
748
Rejection ≥ 20 dB)
758

BPFC-0800

Rejection ≥ 20 dB
822
Start frequency (MHz)
832
Stop frequency (MHz)
862
Rejection ≥ 20 dB)
872

BPFC-0850

Rejection ≥ 20 dB
795
Start frequency (MHz)
815
Stop frequency (MHz)
850
Rejection ≥ 20 dB)
870

BPFC-0850X

Rejection ≥ 20 dB
805
Start frequency (MHz)
814
Stop frequency (MHz)
850
Rejection ≥ 20 dB)
859

BPFC-0900

Rejection ≥ 20 dB
870
Start frequency (MHz)
880
Stop frequency (MHz)
915
Rejection ≥ 20 dB)
925

BPFC-1800

Rejection ≥ 20 dB
1690
Start frequency (MHz)
1710
Stop frequency (MHz)
1785
Rejection ≥ 20 dB)
1805

BPFC-1900

Rejection ≥ 20 dB
1830
Start frequency (MHz)
1850
Stop frequency (MHz)
1910
Rejection ≥ 20 dB)
1930

BPFC-2100

Rejection ≥ 20 dB
1905
Start frequency (MHz)
1920
Stop frequency (MHz)
1980
Rejection ≥ 20 dB)
1995

BPFC-2600

Rejection ≥ 20 dB
2450
Start frequency (MHz)
2500
Stop frequency (MHz)
2570
Rejection ≥ 20 dB)
2620

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.