Key facts

  • R&S®NGE102B with two or R&S®NGE103B with three channels
  • Max. output power of 66 W with R&S®NGE102B, 100 W with R&S®NGE103B
  • Max. output voltage of 32 V per channel
  • Electronic fuse (OCP), overvoltage (OVP)/ -power(OPP)/ -temperature protection (OTP)
  • USB interface (VCP/TMC), optional LAN (LXI), optional wireless LAN, optional digital I/O (4bit)

A partir de 765 EUR

Reduced to the max

The R&S®NGE100B DC Power supply series consists of robust, high-performance, affordable instruments. They offer high efficiency combined with low ripple plus a variety of comfort functions that are not usually found in this class of power supplies.

Features & benefits

All channels galvanically isolated and earth-free

The circuitry of each single channel is completely separated from the others, there is no connection to chassis ground. This makes it easy to combine the channels to drive bipolar circuitries that might need +12 V/–12 V, for example, and avoids any ground problems in complex DUTs.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Driving a bipolar circuit

Combine channels to drive bipolar circuitries that might need + 12 V and – 12 V, for example, without ground problems in complex DUTs.

Parallel and serial operation

Because all channels are electrically equivalent, they can be combined in serial mode to achieve higher voltages. Up to 96 V can be achieved with the R&S®NGE103B, up to 64 V with the R&S®NGE102B. In parallel mode, the channels can be bundled for higher current. Up to 6 A can be achieved when combining two channels. Using all three channels of the R&S®NGE103B, even 9 A are possible.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Parallel and serial operation

The output channels can be combined in serial or parallel to achieve higher voltages or higher currents.

Protection functions

For each channel, users can separately set the:

  • Maximum current (electronic fuse, overcurrent protection, OCP)
  • Maximum voltage (overvoltage protection, OVP)
  • Maximum power (overpower protection, OPP)

If such a limit is reached, the affected output channel will be automatically switched off and a message will be displayed. The overcurrent protection can be linked to other channels (FuseLink function). In this case, the channel exceeding the maximum current level and all linked channels will be switched off.

R&S®NGE100B DC Power Supply Series
Open Lightbox

Protection functions

If a limit is reached, the affected output channel will be automatically switched off and a message will be displayed.

Color-coding of operating conditions

All operating conditions are shown clearly on the 3.5" QVGA display (320 × 240 pixel), including the output power and the status of any protective functions. Colors indicate the different operating conditions:

  • Active outputs are shown in green when working in constant voltage mode and in red when working in constant current mode
  • Inactive outputs are displayed in white. Whenever a channel is in the setting mode, the number to be set is marked by a blue background.
R&S®NGE100B DC Power Supply Series
Open Lightbox

The operating conditions are marked by colors

Constant voltage is indicated in green, constant current in red, inactive channels are shown in white, a blue background indicates a channel in setting mode.

Connectivity

  • Front connectors with 4 mm safety binding posts
  • USB interface (virtual COM port and TMC class)
  • LAN interface (LXI) with integrated web server (R&S®NGE-K101 option) 
  • Wireless LAN, unique in this class (R&S®NGE-K102 option)
  • Digital trigger in/out (4-bit) on the rear (R&S®NGE-K103 option)
R&S®NGE100B DC Power Supply Series
Open Lightbox

Digital I/O

Channel 1 of the optional digital I/O interface is used as a trigger input.

Available models
Model name
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at
R&S®NGE102B

Order number 5601.3800.02

Number of output channels
2
Max. output power
66 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Starting at
R&S®NGE103B

Order number 5601.3800.03

Number of output channels
3
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 3 A
Starting at
Specifications
Electrical specifications
Number of output channels   2/3
Total output power   max. 66 W/100 W
Maximum output power per channel   33,6 W
Output voltage per channel   0 V to 32 V
Maximum output current per channel   3 A
Voltage ripple and noise (20 Hz to 20 MHz)   typ. < 1.5 mV (RMS)
    < 20 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz)   < 2 mA (RMS) (meas.)
Load recovery time*1)   < 200 µs (meas.)
Programming/readback resolution Voltage 10 mV
  Current 1 mA
Readback accuracy (± (% of output + offset)) Voltage < 0.1% + 20 mV
  Current < 0.1% + 5 mA
Special functions
Measurement functions   voltage, current, power, energy
Protection functions   OVP, OCP, OPP, OTP
FuseLink function  
Fuse delay at power-up  
Sense function   -
Sink mode   -
Output sequencing   -
Trigger input/output   -
Arbitrary function   ● (EasyArb)
Analog/modulation interface  
Data logging   -
Display and interfaces
Display   3,5" QVGA
Rear panel connections    
Remote control interfaces   standard: USB; optional: LAN, WLAN
General data
Dimensions (W × H × D)   222 × 97 × 310 mm
Weight   4.9 kg/5.0 kg
Rack installation   R&S®HZC95 option
*1) 10% to 90% load change within a band of ± 20 mV of set voltage.

Available options

General analysis
Product
Description
Ethernet Remote Control
R&S®NGE-K101

Order number 5601.2204.03

Description
Ethernet Remote Control
Wireless LAN Remote Control
R&S®NGE-K102

Order number 5601.2210.03

Description
Wireless LAN Remote Control
Digital Trigger I/O
R&S®NGE-K103

Order number 5601.2227.03

Description
Digital Trigger I/O
General accessories
Product
Description
19" Rackmount kit
R&S®HZC95

Order number 5800.2054.02

Description
19" Rackmount kit, 2HU,for R&S®HMC family 

Further information

DC Power supplies & Power analyzer promotion

Save more than 20% on fully equipped power analyzer, DC power supplies and power meter from Rohde & Schwarz, now through August 31st, 2021

More information

Flyer: Power supplies. Versatile and compact.

Unique features for better results. Different power supply classes. Connectivity – everything you need.

Download now

Teaching-Software for Multi-User Student Labs

The R&S®CDS campus dashboard software simplifies teaching of student groups in laboratories with multiple workbenches.

More information

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Deseo recibir información de Rohde & Schwarz por

Permiso de marketing

¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para test y medida, seguridad en las comunicaciones, monitorización y medidas de redes, broadcast y multimedia así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.