R&S®SMB100B RF signal generator

R&S®SMB100B RF signal generator
Ingrandisci immagine
R&S®SMB100B RF signal generator
Ingrandisci immagine
R&S®SMB100B RF signal generator
Ingrandisci immagine
R&S®SMB100B RF signal generator
Ingrandisci immagine
R&S®SMB100B RF signal generator
Ingrandisci immagine
R&S®SMB100B RF signal generator, Front viewR&S®SMB100B RF signal generator, Front HighR&S®SMB100B RF signal generator, Side viewR&S®SMB100B RF signal generator, Back viewR&S®SMB100B RF signal generator, Hero view

Key Facts

  • Frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz
  • Outstanding single sideband (SSB) phase noise of < –134 dBc (meas.) at 1 GHz and an offset of 20 kHz
  • Very low wideband noise of < –153 dBc (typ.) at 15 MHz < f ≤ 6 GHz and an offset of 30 MHz
  • Ultra high output power of 34 dBm (meas.) at 1 GHz
  • Compact form factor with 2 HU and ¾ 19" width

Perfect combination of performance and usability in a compact size

The new R&S®SMB100B RF signal generator is all about performance and versatility in a small footprint. Outstanding spectral purity and very high output power combined with comprehensive functionality and very simple operation are some of the impressive features of the R&S®SMB100B. It offers a frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz.

Features & benefits

Performance and usability in a compact sizev

Outstanding spectral purity, very high output power and comprehensive functionality are impressive features of the R&S®SMB100B

The new R&S®SMB100B RF signal generator is all about performance and versatility in a small footprint combined with comprehensive functionality and very simple operation.

  • Frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz
  • Compact form factor with 2 HU and 3/4 19" width
  • Large, state-of-the-art 5" GUI with touchscreen

R&S®SMB100B with connected R&S®NRP power sensor (via USB).
Ingrandisci immagine

R&S®SMB100B with connected R&S®NRP power sensor (via USB).

Perfect for signal quality

Very low SSB phase noise of < –134 dBc (meas.) at 1 GHz and an offset of 20 kHz

In order to improve a DUT, the signal quality of the signal source has to be significantly better than the DUT’s performance. Thanks to its innovative synthesizer design, the R&S®SMB100B has very low SSB phase and wideband noise and excellent suppression of nonharmonic signal components.

SSB phase noise (1 GHz, 1 Hz bw, meas.)
Ingrandisci immagine

SSB phase noise (1 GHz, 1 Hz bw, meas.)

SSB phase noise of the R&S®SMB100B base unit, with the R&S®SMBB-B1 option (OCXO) and with the R&S®SMBB-B1H option (high performance OCXO).

Perfect for output power

Ultra high output power of 34 dBm (meas.) at 1 GHz

The R&S®SMBB-K31 high output power option provides 28 dBm at 1 GHz and 24 dBm at 6 GHz (measured values) – easy keycode activation. Ultra high output power of 34 dBm at 1 GHz and 31 dBm at 6 GHz with the additional R&S®SMBB-B32 ultra high output power option (measured values).

Maximum output power
Ingrandisci immagine

Maximum output power

Measured output power for the base unit, with the high power option (R&S®SMBB-K31) and with the additional ultra high power option (R&S®SMBB-B32).

Perfect for use

The user friendliness of the R&S®SMB100B is evident in many ways

The RF signal generator is simple to operate, supports working with a connected R&S®NRP power sensor and can emulate legacy instruments. In addition one can create its own "user menu".

The R&S®SMB100B main screen and user menu
Ingrandisci immagine

The R&S®SMB100B main screen and user menu

Example of a user menu. The individually composed parameters can be directly set in this menu.

Variable reference frequency inputs/outputs

The R&S®SMB100B provides various ways to output (or input) reference signals. The 1 MHz to 100 MHz variable external reference frequency input (R&S®SMBB-K704 option) allows the R&S®SMB100B to be easily integrated into existing test environments. The received reference frequency can also be output to a separate reference output (for details please refer to the data sheet). Extremely good phase stability between multiple R&S®SMB100B instruments can be achieved with the optional 1 GHz reference frequency input and output (R&S®SMBB-B3 option).

Variable reference frequency inputs/outputs
Ingrandisci immagine

Variable reference frequency inputs/outputs

R&S®LegacyPro

Refresh your T&M equipment

When individual pieces of equipment become obsolete before the entire ATE system does, regular calibration and repair of obsolete equipment is an expensive, timeconsuming and challenging task. Replacing obsolete test equipment with equivalent state-of-the-art instruments should be straightforward and require minimal hardware and software changes. The R&S®LegacyPro code emulation fulfills these requirements, reducing the workload and eliminating risks.

R&S®LegacyPro code emulation
Ingrandisci immagine

R&S®LegacyPro code emulation

Emulation of legacy generators from Rohde & Schwarz and other vendors.

R&S®NRP power sensor connectivity

An R&S®NRP power sensor can be connected to the R&S®SMB100B

A DUT is rarely connected directly to the generator. There are often cables and other components between the generator and the DUT. This shifts the reference plane from the generator’s RF output to the DUT. An R&S®NRP power sensor can be connected to the R&S®SMB100B to allow extremely precise calibration (tenth of a dB) at this new reference plane.

Extremely precise calibration
Ingrandisci immagine

Extremely precise calibration

R&S®SMB100B with external devices: R&S®NRP power sensor (via USB); setup for setting the target power at the new reference plane.

UCOR (user correction)

Compensation of an external frequency response by the R&S®SMB100B with a connected R&S®NRP power sensor

DUTs are often connected to the signal generator via long cables or other frequency-dependent components. It is therefore very important to compensate the frequency response. The R&S®SMB100B provides a user correction (UCOR) function for this purpose. Together with R&S®NRP power sensor the UCOR values are automatically determined by a push of a button. With UCOR, a frequency response compensated RF signal is available at the new reference plane.

Setup and UCOR function
Ingrandisci immagine

Setup and UCOR function

Relative output power display when using cables and other components (with their own frequency responses) between the R&S®SMB100B and a DUT.

Available options

Frequency options
Product
Descrizione
R&S®SMBB-B101

Order Number 1422.5005.02

Descrizione

Frequency option
 

8 kHz to 1 GHz

R&S®SMBB-B103

Order Number 1422.5105.02

Descrizione

Frequency option

8 kHz to 3 GHz

R&S®SMBB-B106

Order Number 1422.5205.02

Descrizione

Frequency option

8 kHz to 6 GHz

Reference oscillator options
Product
Descrizione
R&S®SMBB-B1

Order Number 1422.5305.02

Descrizione

OCXO Reference Oscillator

Only one of the R&S®SMBB-B1 or R&S®SMBB-B1H options can be installed.

R&S®SMBB-B1H

Order Number 1422.5405.02

Descrizione

High Performance OCXO Reference Oscillator

Only one of the R&S®SMBB-B1 or R&S®SMBB-B1H options can be installed.

R&S®SMBB-B3

Order Number 1422.5505.02

Descrizione

100 MHz, 1 GHz Ultra Low Noise Reference Input and Output

R&S®SMBB-K704

Order Number 1422.6301.02

Descrizione

Variable Reference Input from 1 MHz to 100 MHz

Output power options
Product
Descrizione
R&S®SMBB-K31

Order Number 1422.5705.02

Descrizione

High Output Power, 1/3/6 GHz

R&S®SMBB-B32

Order Number 1422.5740.02

Descrizione

Ultra High Output Power 1/3/6 GHz

Requires the R&S®SMBB-K31 option.

Analog modulation options
Product
Descrizione
R&S®SMBB-K22

Order Number 1422.5905.02

Descrizione

High Performance Pulse Modulator

R&S®SMBB-K23

Order Number 1422.6001.02

Descrizione

Pulse Generator

R&S®SMBB-K24

Order Number 1422.6053.02

Descrizione

Multifunction Generator

R&S®SMBB-K27

Order Number 1422.6101.02

Descrizione

Pulse Train

R&S®SMBB-K720

Order Number 1422.6201.02

Descrizione

AM/FM/φM

R&S®SMBB-B5

Order Number 1422.5605.02

Descrizione

Stereo/RDS Coder

Requires the R&S®SMBB-K720 option.

Extras
Product
Descrizione
R&S®SMBB-B86

Order Number 1422.5805.02

Descrizione

Remote Control Interface (GPIB and USB)

R&S®ZZA-KNA23

Order Number 1177.8084.00

Descrizione

19" Rackmount Kit

R&S®TS-USB1

Order Number 6124.2531.00

Descrizione

USB serial adapter for RS-232 remote control

Documentation
Product
Descrizione
R&S®DCV-2

Order Number 0240.2193.18

Descrizione

Documentation of Calibration Values

R&S®SMBB-ACA

Order Number 1422.6147.02

Descrizione

R&S®SMB100B Accredited Calibration

Recommended extras
Product
Descrizione

Order Number 1424.6738.02

Descrizione

High-power Three-path Diode Power Sensor

For USB operation
Measurement range: 10 nW to 15 W
Frequency range: 10 MHz to 18 GHz
N (m) connector

R&S®NRP-ZKU

Order Number 1419.0658.02

Descrizione

USB-A interface cable, length: 0.75 m

Application videos

SMB100B Output power
Ultra high output power

The R&S®SMB100B offers with its ultra high output power option a calibrated one-box solution that saves space and money.

SMB100B SCPI makro recorder
SCPI macro recorder

The built-in SCPI macro recorder with code generator can automatically record all manual settings and create an executable MATLAB® script.

SMB100B UCOR user correction
UCOR (user correction)

With UCOR a frequency response compensated RF signal is available at the new reference plane for the DUT.

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.