Key facts

  • Power measurement range: 50 µW to 12 kW
  • Analog bandwidth: DC to 100 kHz
  • Sampling rate: 500 ksample/s
  • Basic accuracy: 0.05 %

A partire da EUR 1.790

All-in-One

The compact class that has it all

The R&S®HMC8015 Power analyzer is a compact tester for AC/DC load and standby current characterization that enables measurements without additional tools such as a computer or remote infrastructure. In addition to a numerical and graphical display with 26 key parameters, the instrument delivers performance and compliance protocols in line with IEC 62301, EN 50564 and EN 61000-3-2.

Features & benefits

Policy tester

EN61000-3-2, EN50564, IEC62301

The R&S®HMC8015 Power analyzer performs automated tests in compliance with:

  • EN61000-3-2: harmonic currents for EMC, CE approval
  • EN50564: standby power consumption
  • IEC62301: standby power consumption

A step-by-step wizard guides the user through the measurement and configures the required instrument parameters. This minimizes measurement errors and makes results quickly visible. No prior knowledge of the above mentioned standards is nesseccary. After the test, a protocol is automaticlly generated.

Option/voucher HOC153/HVC153 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Typical test setup with R&S®HZC815 socket adapter

Data logging

CSV to USB or remotely via interface

  • Logging of up to 10 measurement parameters
  • Recording 10 readings per second
  • Absolute time stamps with 100ms resolution
  • Directly to USB flash drives (FAT32)
  • Logging data saved in configurable CSV format
  • Directly utilizable in Excel spreadsheets
R&S®HMC8015 Power analyzer
Open Lightbox

Logging data directly utilizable in Excel sheets

Production tester

Limit testing with PASS / FAIL

Limit testing

  • Numerical display with limit bar
  • Up to 6 limits freely configurable
  • PASS / FAIL for one limit via rear connectors
  • Analog output representing limit bar
  • Digital output showing limit violations

 
Production environment

  • Remote control via Ethernet (LXI), USB or GPIB interface
  • SCPI command set
  • Rackmount kit capability

Option/voucher HOC152/HVC152 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Huge variety of interfaces for remote control

Waveform function

Oscillographic waveform chart

  • Auto-scaling waveform
  • Automatic hardware-based triggering
  • Simultaneous display of voltage, current and power for one period
  • Auto-measurement for U(rms), I(rms), FPLL, P

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Simultaneous display of voltage, current and power for one period

Harmonic analysis

Harmonics as bar chart or table view

  • Harmonics visualized as bar chart or table view
  • Calculation covering 50 harmonics
  • Basic wave as 100% reference
  • Logarithmic display to never miss any details
  • Export function for easier report generation

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015
Open Lightbox

Harmonics visualized as bar chart

Energy meter

Real-time integrator

  • High precision and gapless acquisition
  • Hardware-based, real-time integration
  • Distinguishing positive and negative Wh, Ah
  • Acquisition modes: manually, time-based, event-based (ext. trigger)
  • Logging functionality as standard

Application: Accumulated energy methods for unstable power measurements

R&S®HMC8015
Open Lightbox

High precision and gapless acquisition

Inrush measurement

  • Single shot to analyze fast switching-on operations
  • Configurable hardware trigger
  • Data export function for further analysis

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015
Open Lightbox

Trend chart view showing six example switch-on operations for the DUT

Available models
Product Name
Power measurement range
Analog bandwidth
Sampling rate
Basic accuracy
Interfaces
Starting at
R&S®HMC8015

Order number 3593.8646.02

Power measurement range
50 µW to 12 kW
Analog bandwidth
DC to 100 kHz
Sampling rate
500 ksample/s
Basic accuracy
0.05 % of reading
Interfaces
LAN, USB
Starting at
R&S®HMC8015-G

Order number 3593.8875.02

Power measurement range
50 µW to 12 kW
Analog bandwidth
DC to 100 kHz
Sampling rate
500 ksample/s
Basic accuracy
0.05 % of reading
Interfaces
LAN, USB, IEEE-488 (GPIB)
Starting at
Specifications
Specifications
Analog bandwidth   DC to 100 kHz
Frequency accuracy   0.1 % of reading
A/D converter resolution voltage and current 16 bit
Basic accuracy   0.05 % of reading
Display resolution   5 digits, 10 updates/s
Sampling frequency   500 kHz
Input impedance   2 MΩ
PLL synchronization sources   U, I, external
Filters
   Analog signal filter   1 kHz
   Digital filter depends on measurement frequency adaptive filter
   Frequency filter independent of analog signal filter 500 Hz
Additional inputs/outputs   BNC, rear panel
   Analog input   ±10 V (U peak)
   Analog input accuracy   0.5 % of reading
   Analog output   ±5 V (U peak)
Digital input
   Limits (PASS/FAIL) bandwidth 100 kHz
  PWM 1 kHz
  state ≤ 10 Hz
   Signal threshold logical zero 0 V to 2 V
  logical one 3 V to 24 V
Digital output up to 100 mA source/sink 5 V, TTL
Display   8.9 cm (3.5") TFT (color)
  resolution 320 × 240 pixel (QVGA)
Network connection AC 100 V to 115 V/230 V at 50 Hz to 60 Hz
Power consumption   max. 35 W, typ. 15 W
Operating temperature range   +5 °C to +40 °C
Storage temperature range   –25 °C to +60 °C
Standards   CAN/CSA-C22.2 NO. 61010-1, UL 61010-1,
DIN EN 61010-1, DIN EN 61326-1, DIN EN 55011
Common mode voltage   CAT II, 600 V (U RMS)
Dimensions   222 mm × 88 mm × 280 mm
(8.74 in × 3.46 in × 11.02 in)
Weight   approx. 3.25 kg (7.16 lb)
Warm-up time   60 min

Available options

General analysis
Product
Description

Order number 3622.0795.02

Description
Advanced analysis, voucher upgrade

Order number 3622.0789.02

Description
Advanced analysis, factory direct order

Order number 3622.3788.02

Description
Advanced I/O, voucher upgrade

Order number 3622.3542.02

Description
Advanced I/O, factory direct order

Order number 3622.3794.02

Description
Compliance test, voucher upgrade

Order number 3622.3559.02

Description
Compliance test, factory direct order
Socket adapter
Product
Description
R&S®HZC815
R&S®HZC815-EU

Order number 3593.8852.02

Description
Socket adapter for R&S®HMC8015, EU connector
R&S®HZC815
R&S®HZC815-GB

Order number 3622.2246.02

Description
Socket adapter for R&S®HMC8015, GB connector
R&S®HZC815
R&S®HZC815-US

Order number 3622.2252.02

Description
Socket adapter for R&S®HMC8015, US connector
R&S®HZC815
R&S®HZC815-CHN

Order number 3623.3952.02

Description
Socket adapter for R&S®HMC8015, CHN/AUS connector
Current probes
Product
Description
R&S®HZC50
R&S®HZC50

Order number 3622.4690.02

Description
AC/DC current probe, 30 A, 4 mm connectors
R&S®HZC51
R&S®HZC51

Order number 3622.4684.02

Description
AC/DC current probe, 1000 A, 4 mm connectors
Rackmount kit
Product
Description
19" Rackmount kit
R&S®HZC95

Order number 5800.2054.02

Description
19" Rackmount kit, 2HU,for R&S®HMC family 

Related videos

Test di conformità IEC 61000-3-2 con l’analizzatore di potenza R&S®HMC8015

Una guida rapida alle le misure di conformità secondo la norma IEC61000-3-2

gen 29, 2019

Test di conformità IEC62301 ed EN50564 con analizzatore di potenza R&S®HMC8015

Scoprite come eseguire i test di conformità secondo le norme IEC62301 ed EN50564 in pochi semplici passaggi

gen 29, 2019

Misura dei picchi di corrente con l’analizzatore di potenza R&S®HMC8015

Scoprite come misurare e salvare comodamente i risultati della misura

gen 29, 2019

DC Power supplies promotion

DC Power supplies & Power analzyer promotion

Save more than 20% on fully equipped power analyzer, DC power supplies and power meter from Rohde & Schwarz, now through August 31st, 2021

Applications

Conducted Emission Limits in line with IEC/EN 61000-3-2

Automated testing of limits for harmonic current emissions (IEC 61000-3-2) using the R&S®HMC8015 Power Analyzer. A step-by-step wizard guides the user through the measurement.

More information

Standyby Power Consumption in line with IEC 62302 and EN 50564

Automated testing of standby power consumption (IEC 62301, EN 50564) using the R&S®HMC8015 Power Analyzer. A step-by-step wizard guides the user through the measurement.

More information

Measurement of Inrush Currents

Performing in-rush current measurements using the R&S®HMC8015 Power Analyzer

More information

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Desidero ricevere informazioni da Rohde & Schwarz tramite

Autorizzazione al marketing

Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.