Mixed signal option oscilloscope hardware

Oscilloscope hardware

Mixed signal option oscilloscope hardware
Abrir o Lightbox
Mixed signal option oscilloscope hardware
Abrir o Lightbox
Mixed signal option oscilloscope hardware
Abrir o Lightbox
Mixed signal option oscilloscope hardware
Abrir o Lightbox
Mixed signal option oscilloscope hardware, Application Image Mixed signal option oscilloscope hardware, Application Image Mixed signal option oscilloscope hardware, Front view Mixed signal option oscilloscope hardware, Screenshot

Key Facts

  • Easy upgrade of any Rohde & Schwarz oscilloscope to an MSO
  • Precision measurement: up to 5 Gsample/s sampling rate
  • Deep memory: acquire long signal sequences
  • Comprehensive processing and analysis functions
  • Analysis of serial protocols, even with digital channels
  • Multi-domain icon

Brief description

The R&S®B1 MSO options turns Rohde & Schwarz oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO). Mixed signal oscilloscopes are hybrid test instruments that combine the measurement capabilities of digital oscilloscopes with the analysis capabilities of logic analyzers.

Features & benefits

More signal details

More signal details thanks to high time resolution across the entire memory depth

With a sampling rate of 5 Gsample/s, the R&S®B1 option for the R&S®RTO, R&S®RTE and R&S®RTM oscilloscopes provides a maximum time resolution of 200 ps for the digital channels. This sampling rate is available across the entire memory depth. As a result, the MSO option is even capable of detecting critical events such as narrow, widely separated glitches.

The digital channels of the R&S®RTO oscilloscope operate with 200 ps resolution and can detect short glitches.
Abrir o Lightbox

The digital channels of the R&S®RTO oscilloscope operate with 200 ps resolution and can detect short glitches.

Precise triggering on signal events

The digital channel resolution of 200 ps makes these channels a precise trigger source. The R&S®B1 offers numerous trigger types for debugging and analysis, such as edge, width, pattern and serial pattern. These triggers can be combined with holdoff conditions. For the trigger source, the user can select individual digital channels, bus signals or any logical combination of digital channels by applying logic operations such as AND, OR and XOR.

Select from a comprehensive list of trigger types for the digital channels.
Abrir o Lightbox

Select from a comprehensive list of trigger types for the digital channels.

Fast fault finding

High acquisition and analysis rate for fast fault finding

Hardware-based signal processing of measured digital waveforms extends from acquisition and triggering to analysis functions such as cursor functions and measurements, and even includes the visualization of the results. Parallel processing of all measured digital signals allows an acquisition and analysis rate of max. 200 000 waveforms per second with the R&S®RTO and R&S®RTE oscilloscopes, ensuring that rare events are detected quickly and reliably.

Abrir o Lightbox

Straightforward display of digital signals

The R&S®RTO and R&S®RTE oscilloscopes’ R&S®SmartGrid function facilitates placement of digital channels on the screen. The digital channel activity remains visible in the signal icons irrespective of the acquisition state. The binary signals from the individual digital channels obtained between two screen dumps are superimposed in the measurement diagram. You see an overview of the frequency of the binary states and of the edge transitions.

Use the R&S®SmartGrid function to position the digital channels on the display according to your needs.
Abrir o Lightbox

Use the R&S®SmartGrid function to position the digital channels on the display according to your needs.

Comprehensive processing and analysis functions

To efficiently analyze measured waveforms, all Rohde & Schwarz oscilloscopes offer the R&S®B1 option with a range of automatic time measurements, including statistical evaluation. Automatic measurements can be performed on all digital channels and their logical combinations. The cursor also supports the decoding of the bus value at the cursor position. The history view function allows you to access measurement waveforms in the acquisition memory and apply analysis functions to them.

Detailed analysis on the digital channels.
Abrir o Lightbox

Detailed analysis on the digital channels.

Analysis of serial protocols

Analysis of serial protocols, even with digital channels

The protocols of serial interfaces such as I²C, SPI, UART/RS-232, CAN, LIN and FlexRay™ can also be triggered and decoded using the R&S®RTO-B1 digital channels and the appropriate serial protocol options.

Protocol decoding such as I²C decoding is also supported on digital channels.
Abrir o Lightbox

Protocol decoding such as I²C decoding is also supported on digital channels.

Low test point loading

Low test point loading due to active probe solution

The digital inputs are grouped into logic probes with eight channels. High input impedance combined with low input capacitance of 100 kΩ || 4 pF ensures high signal fidelity and low loading of the test points.

Low test point loading due to active probe solution
Abrir o Lightbox

Low test point loading due to active probe solution

Available models

Available models
Modelos
Number of channels
Bandwidth
Max. sampling rate
Max. memory depth
Base unit

R&S®RTO-B1

Order Number 1326.3558.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
200 Msample
Base unit

R&S®RTE-B1

Order Number 1326.3570.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
100 Msample
Base unit

R&S®RTA-B1

Order Number 1335.7823.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
2.5 Gsample/s (16 ch)
5 Gsample/s (8 ch)
Max. memory depth
100 Msample (16 ch)
200 Msample (8 ch)
Base unit

R&S®RTM-B1

Order Number 1335.8988.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
2.5 Gsample/s (16 ch)
5 Gsample/s (8 ch)
Max. memory depth
40 Msample (16 ch)
80 Msample (8 ch)
Base unit

R&S®RTB-B1

Order Number 1333.1105.02

Number of channels
16
Bandwidth
300 MHz
Max. sampling rate
1.25 Gsample/s
Max. memory depth
10 Msample
Base unit

R&S®RTC-B1

Order Number 1335.7281.03

Number of channels
8
Bandwidth
300 MHz
Max. sampling rate
1 Gsample/s
Max. memory depth
1 Msample
Base unit

R&S®RTH-B1

Order Number 1325.9981.02

Number of channels
8
Bandwidth
250 MHz
Max. sampling rate
1.25 Gsample/s
Max. memory depth
125 ksample
Base unit

R&S®RTO6-B1

Order Number 1801.6741.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
200 Mpts
Base unit

R&S®MXO4-B1

Order Number 1335.4130.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
400 Mpoints
Base unit

R&S®RTP-B1

Order Number 1333.2424.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
200 Mpoints
Base unit

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.