Key Facts
- Fast and accurate power measurements for CW and modulated signals
- 100,000 readings/s
- Control and monitoring via LAN and USB
- Sensors for high-power applications
- Flexible operation with R&S®NRX base unit
Key Facts
The R&S®NRPxxS/SN power sensors use three separate diode paths, each operated in the optimum detector range. As a result, the average power can be determined with high accuracy independent of the modulation type. Measurement results are hardly affected by interfering signals or harmonics. The R&S®NRPxxS/SN power sensors therefore behave in a way similar to thermal power sensors but offer significantly higher speed. They provide up to 93 dB dynamic range with an excellent lower measurement limit of –70 dBm.
Ideal solution for many applications
Three-path diode power sensors are suitable for numerous applications, since they support continuous average, burst average, timeslot average, gate average and trace measurements. Featuring outstanding performance and unprecedented measurement speed and accuracy, the sensors can be used to perform precise average power measurements on wireless signals such as GSM and 3GPP as well as on higher bandwidth signals such as LTE, LTE-Advanced or 5G.
Improved thre-path concept
The R&S®NRPxxS(N) power sensors use three separate diode paths, each operated in the optimum detector range. The average power can be determined with high accuracy irrespective of the modulation type. Measurement results are hardly affected by interfering signals or harmonics. The R&S®NRPxxS(N) power sensors therefore behave similar to thermal power sensors but offer significantly higher speed and up to 93 dB dynamic range.
Even at low levels down to -70 dBm
To increase measurement accuracy at low levels, it is necessary to average multiple measured values. While averaging reduces the noise component, it also slows down the measurement. The R&S®NRPxxS(N) power sensors have therefore been designed with an extremely low measurement noise in mind.
The R&S®NRPxxS(N) power sensors can perform measurements down to a lower limit of –70 dBm with the highest speed and accuracy currently available on the market.
Unlimited time measurement with up to 100.000 measurements/s
In fast continuous average mode, the R&S®NRPxxS(N) power sensors can perform up to 100,000 triggered measurements/s with a minimum trigger repetition time of 100 µs without losing any measurement. This measurement speed is achieved by using the buffered mode. In buffered mode, all measured data is collected inside the sensor and transmitted in one block to the sensor’s host. The R&S®NRPxxS(N) sensors perform the new fast mode without time limitation!
Perform power measurements up to 30 W
The R&S®NRP18S-10, R&S®NRP18S-20 and R&S®NRP18S-25 high-power three-path diode power sensors consist of an R&S®NRP18S and a 10/20/25 dB upstream attenuator. They are able to perform power measurements up to 2 W, 15 W and 30 W. When used with the attenuator, mismatch errors between the sensor and attenuator are automatically corrected. The S-parameters for the attenuator are determined and stored in the sensor during production.
Specially designed for use in thermal vacuum (TVAC) chambers
The R&S®NRPxxSN-V TVAC-compliant power sensor is designed for satellite communications applications in a frequency range up to 67 GHz. All components are baked in a vacuum chamber during the production process, so outgassing is reduced to a minimum. Thanks to their LAN capability, the power sensors can be easily controlled and monitored from outside the chamber while the venting holes in the housing ensure pressure equalization.
Order Number 1419.0658.02
USB-A interface cable, length: 0.75 m
Order Number 1419.0658.03
USB-A interface cable, length: 1.5 m
Order Number 1419.0658.04
USB-A interface cable, length: 3 m
Order Number 1419.0658.05
USB-A interface cable, length: 5 m
Order Number 1425.2442.02
USB-C interface cable, length: 0.75 m
Order Number 1425.2442.03
USB-C interface cable, length: 1.5 m
Order Number 1425.2442.04
USB-C interface cable, length: 3.0 m
Order Number 1419.0664.02
6-pole interface cable, length: 1.5 m
Order Number 1419.0664.03
6-pole interface cable, length: 3 m
Order Number 1419.0664.04
6-pole interface cable, length: 5 m
Order Number 1424.9408.02
8-pole interface cable, length: 1.50 m
For connection to R&S®NRX
Order Number 1424.9408.03
8-pole interface cable, length: 3.00 m
For connection to R&S®NRX
Order Number 1424.9408.04
8-pole interface cable, length: 5.00 m
For connection to R&S®NRX
Order Number 1146.7740.02
USB sensor hub
R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.
Order Number 0240.2187.06
Documentation of calibration values
Order Number 1173.6506.02
Printout of DCV
Order Number 1700.3977.02
Waveguide Coax Adapter WR12 to 1.35mm (f)
Waveguide Coax Adapter WR12 to 1.35 mm female with S-Parameter characterisation, WG stabilzation bracket for USB and LAN NRP power sensors 60 - 90 GHz
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz
1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).
2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.
3. A participação é gratuita e não depende da compra de mercadorias ou serviços.
4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.
5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:
Prêmio: 1 osciloscópio digital R&S®RTB2000
6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.
7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.
8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.
9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.
10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.
11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.
12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.
13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.