Frequency response analysis (Bode plot)

General analysis

Frequency Response Analysis (Bode plot) Control Loop Response
Abrir Lightbox
Frequency Response Analysis (Bode plot) Passive Components
Abrir Lightbox
Frequency Response Analysis (Bode plot) Power Supply Rejection Ratio
Abrir Lightbox
Frequency Response Analysis (Bode plot) Control Loop Response Frequency Response Analysis (Bode plot) Passive Components Frequency Response Analysis (Bode plot) Power Supply Rejection Ratio

Key facts

  • Bandwidth: 10 Hz to 25 MHz
  • Test modes: Fixed or custom amplitude profile
  • Points per decade: Logarithmic gain and linear phase
  • Analysis: Waveform cursors and tabular view of test results

Oscilloscope software

The R&S®RTx-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio. The frequency response analysis option uses the oscilloscope’s built-in waveform generator to create stimulus signals ranging from 10 Hz to 25 MHz. Measuring the ratio of the stimulus signal and the output signal of the DUT at each test frequency, the oscilloscope plots gain and phase logarithmically.

Características y ventajas

Amplitude profile

The R&S®RTx-K36 frequency response analysis (Bode plot) option allows users to profile the amplitude output level of the generator. This helps to suppress the noise behavior of the DUT when performing a control loop response or power supply rejection ratio and to improve signal-to-noise ratio (SNR). It is possible to define up to 16 steps.

Open Lightbox

Amplitude profile

Improve resolution and markers support

You can choose the points per decade to set up and modify the resolution of your plot. The oscilloscope supports up to 500 points per decade. Markers can be dragged to the desired position, directly on the plotted trace. A legend displays the corresponding coordinates of the markers. To determine the crossover frequency, set one marker to 0 dB and the second marker to –180° phase shift. Now you can easily determine the phase and gain margin.

Open Lightbox

Vary points per decade

Measurement table

Furthermore, you can view the results in a table. The table of measurement results details information about each measured point, consisting of frequency, gain and phase shift. In case you use cursors, for ease of use, the associated row of the result table is highlighted. For reporting, screenshots, table results or both can be quickly saved to a USB device.

Open Lightbox

Measurement table

Broad probe portfolio

Accurate control loop response or power supply rejection ratio characterization highly depends on choosing the right probes, since peak-to-peak amplitudes of both Vin and Vout can be very low at some test frequencies. These values would be buried in the oscilloscope’s noise floor or in the switching noise of the DUT itself. We recommend the low-noise R&S®RT-ZP1X 38 MHz bandwidth 1:1 passive probes. These reduce measurement noise and provide the best SNR.

Open Lightbox

R&S®RT-ZP1X 38 MHz 1:1 passive probe

Available models


  • Option Name

    R&S®RTA-K36

    Order number 1335.7975.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit
  • Option Name

    R&S®RTB-K36

    Order number 1335.8007.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit
  • Option Name

    R&S®RTM-K36

    Order number 1335.9178.02

    Amplitude profile
    Markers support
    Define max. phase
    Min - Meas.delay
    Base unit

Gama de osciloscopios

Osciloscopios

Osciloscopios a la medida de sus necesidades y su presupuesto, desde modelos de alta gama hasta equipos de alto rendimiento

Más información

Opciones de software para osciloscopios

Amplíe las características de su osciloscopio con el software de aplicación de Rohde & Schwarz.

Más información

Sondas para osciloscopio

Configure su osciloscopio a la medida de sus necesidades con sondas y accesorios adecuados para su aplicación.

Más información

Solicitar información

Você tem alguma pergunta ou precisa de mais informações? Simplesmente preencha este formulário e nos comunicaremos com você imediatamente.

Permiso de marketing

Deseo recibir información de Rohde & Schwarz por

¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para test y medida, seguridad en las comunicaciones, monitorización y medidas de redes, broadcast y multimedia así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Gracias.

Su equipo de Rohde & Schwarz

Se ha producido un error. Inténtelo de nuevo más tarde.
Información general y jurídica

Precio de venta sugerido por el fabricante. Este precio no incluye el IVA. Precios y ofertas están destinados exclusivamente para empresarios y no para el consumidor final.