Key facts

  • Max. output power: 80 W
  • Max. voltage per channel: 35 V or 100 V
  • Max. current per channel: 2 A or 6 A
  • Up to 200 V in serial or 12 A in parallel mode with Channel Fusion
  • Data acquisition with 10 sample/s

A partire da 890 EUR

  • 3 year warranty

Linear. Accurate. Affordable.

The R&S®NGA100 power supplies are linear, compact and easy to use. All models have excellent readback accuracy with a low-current range for demanding measurements. Features such as data logging, arbitrary waveforms, built-in statistics and remote sensing make the instruments ideal for various bench applications. Equipped with a number of different remote interfaces, including USB and Ethernet, the R&S®NGA100 power supplies are also great for automated tests. The channel fusion feature extends voltage and current range. Get up to 200 V with the R&S®NGA142 in serial mode and up to 12 A with the R&S®NGA102 in parallel mode. Advanced protection functions keep devices connected and power supplies safe.

Features & benefits

Linear design

Confidently power sensitive circuits

Advanced electronic circuitry is often complex and sensitive to the supply line interference. The linear design of the output stages allows the R&S®NGA100 power supplies to operate with minimum residual ripple and noise. Supplying extremely stable output voltage and current is crucial when developing sensitive components.

Linear design
Open Lightbox

block diagram of a linear power supply

High readback accuracy

with integrated statistics

The R&S®NGA100 power supply series has outstanding programming and readback accuracy to accurately measure and replicate a device’s actual power consumption, even at low voltage and current levels. IoT devices can have multiple sleep modes where current consumption is very low. To accurately determine these operating states, R&S®NGA100 power supplies have a low-current measurement range. Currents below 200 mA are measured with a resolution of 1 μA and an accuracy of ±(0.15 % + 25 μA). In addition, integrated statistics show the min. and max. values for power, voltage and current. These built-in measurements reduce the need for external multimeters and simplify the setup.

High readback accuracy
Open Lightbox

Low-current measurement range

for output currents ≤ 200 mA the measurement resolution is 1 µA

FlexPower

Get the maximum power at various operating points

The R&S®NGA100 series operates with maximum power at various operating points and covers far more applications than single range power supplies. All possible voltage and current combinations are shown in the corresponding FlexPower curves.

FlexPower
Open Lightbox

R&S®NGA101/R&S®NGA102 FlexPower curve per output

Channel Fusion

Double the voltage or current capability of your power supply

The two output channels of the R&S®NGA102 and R&S®NGA142 operate in series or parallel for higher voltage or current. After activating serial or parallel channel fusion, the device will start to act like a one-channel power supply with double voltage or current capability. In serial mode the outputs are connected internally, while the parallel mode requires external wiring. The function enables even more applications to be covered by a single instrument.

Channel Fusion
Open Lightbox

R&S®NGA142 in Channel Fusion serial mode

Extended voltage range up to 200 V

Available models
Product Name
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Starting at
R&S®NGA101

Order number 5601.8002.02

Number of output channels
1
Max. output power
40 W
Output voltage per channel
0 V to 35 V
Output current per channel
0 A to 6 A
Starting at
R&S®NGA141

Order number 5601.8002.03

Number of output channels
1
Max. output power
40 W
Output voltage per channel
0 V to 100 V
Output current per channel
0 A to 2 A
Starting at
R&S®NGA102

Order number 5601.8002.04

Number of output channels
2
Max. output power
80 W
Output voltage per channel
0 V to 35 V
Output current per channel
0 A to 6 A
Starting at
R&S®NGA142

Order number 5601.8002.05

Number of output channels
2
Max. output power
80 W
Output voltage per channel
0 V to 100 V
Output current per channel
0 A to 2 A
Starting at
Specifications
Electrical specifications
Number of output channels R&S®NGA101, R&S®NGA141 1
  R&S®NGA102, R&S®NGA142 2
Total output power R&S®NGA101, R&S®NGA141 Max. 40 W
  R&S®NGA102, R&S®NGA142 Max. 80 W
Maximum output power per channel   40 W
Output voltage per channel R&S®NGA101, R&S®NGA141 0 V to 35 V
  R&S®NGA102, R&S®NGA142 0 V to 100 V
Maximum output current per channel R&S®NGA101, R&S®NGA141 6 A
  R&S®NGA102, R&S®NGA142 2 A
Voltage ripple and noise (20 Hz to 20 MHz) R&S®NGA101, R&S®NGA102 < 0.5 µV (RMS)
< 10 mV (peak-to-peak) (meas.)
  R&S®NGA141, R&S®NGA142 < 1.5 mV (RMS)
< 20 mV (peak-to-peak) (meas.)
Current ripple and noise (20 Hz to 20 MHz)   < 500 >µA (RMS) (meas.)
Load recovery time*1) R&S®NGA101, R&S®NGA102 < 100 µs (meas.)
  R&S®NGA141, R&S®NGA142 < 50 µs (meas.)
Programming resolution voltage   1 mV
Programming resolution current   1 mA
Output measurements
Readback resolution voltage   1 mV
Readback resolution current   100 μA (for currents < 200 mA: 1 µA)
Readback accuracy voltage ± (% of output + offset) R&S®NGA101, R&S®NGA102 < 0.02 % + 5 mV
  R&S®NGA141, R&S®NGA142 < 0.02 % + 10 mV
Readback accuracy current ± (% of output + offset)   < 0.03 % + 500 μA
Special functions
Measurement functions   voltage, current, power
Protection functions   OVP, OCP, OPP, OTP
FuseLink function R&S®NGA102, R&S®NGA142
Fuse delay time  
Sense function  
Sink mode   -
Output sequencing   -
Trigger input/output with R&S®NGA-K103
Arbitrary function CH1 only ● (EasyArb)
Analog/modulation interface  
Data logging   ● (Standard)
Display and interfaces
Display   3.5"/QVGA
Rear panel connections   8-pin connector block (outputs, remote sensing)
Remote control interfaces standard USB-TMC, USB-CDC (virtual COM)
  standard LAN
  with R&S®NGA-K102 WLAN
General data
Dimensions (W × H × D)   222 mm × 97 mm × 448 mm
(8.74 in × 3.82 in × 17.64 in)
Weight R&S®NGA101 6.6 kg (14.5 lb)
  R&S®NGA141 6.9 kg (15.2 lb)
  R&S®NGA102 7.0 kg (15.4 lb)
  R&S®NGA142 7.3 kg (16.1 lb)
Rack installation R&S®HZN96, space for two instruments 19", 2 HU
*1) 10% to 90% load change to within 0.2 % of rated voltage.

Available options

General
Product
Description
R&S®NGA-K102
R&S®NGA-K102

Order number 5601.8419.03

Description
Wireless LAN remote control
R&S®NGA-K103
R&S®NGA-K103

Order number 5601.8425.03

Description
Digital trigger I/O
General accessories
Product
Description
R&S®HZN96

Order number 3638.7813.02

Description
19'' rack adapter, 2HU

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Desidero ricevere informazioni da Rohde & Schwarz tramite

Autorizzazione al marketing

Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.