5. Instruments Drivers vs. Direct SCPI Commands

CH5_InstrumentDriversLayer_16x9.png

In the previous chapters, we learned how to remote control Rohde & Schwarz instruments using direct SCPI commands. As an alternative, Rohde & Schwarz offers free instrument drivers that provide an abstraction layer between your application and the instrument’s SCPI commands.

Instead of using VISA Write / Read functions and direct SCPI commands, you use functions and attributes of an instrument driver. A simple example of such substitution in the LabVIEW rsscope Instrument driver:

The same substitution in C# using the IVI.NET RsScope instrument driver. You set the individual parameters with properties, or set more of them with a method:

For simplicity, the above direct SCPI command pictures do not contain all the operations that the instrument drivers perform. For example, the drivers also wait for the instrument acknowledgment that a command has been executed (see Chapter 6 Measurement Synchronization), and check for potential errors after each command (see Chapter 7 Instrument Error Checking). When you use direct SCPI commands, you have to take care of both of these tasks yourself.

Summarized advantages/disadvantages of using direct SCPI commands

Advantages:

  • Quicker start; Instrument user manual has all the SCPI commands described.
  • Faster execution speed.

Disadvantages:

  • You need to take care of the measurement synchronization and the instrument error checking.
  • You must format arguments into the SCPI commands. This is especially tricky with binary data.
  • When you receive an instrument string response, you need to convert it into an appropriate type (e.g. integer, double or boolean, arrays or binary data).

Summarized advantages/disadvantages of using the instrument drivers

Advantages:

  • Performing error checking after each command. You can switch this off for the critical sections where you require the maximum speed.
  • Synchronization of commands that take long time to complete.
  • Formatting of arguments into the SCPI commands and parsing the instrument responses is already implemented.
  • Instrument drivers come with their own *.chm help files.
  • They always offer the option to write or read direct SCPI commands.

Disadvantages:

  • Longer learning curve, you have to get familiar with the driver structure.
  • A minor overhead. This can be minimized by the correct approach; see Chapter 8 Speed Optimization
  • Sometimes you have to wait until a new instrument option is supported by instrument drivers.

Suitability of Rohde & Schwarz Instrument drivers for different programming languages

The following table shows, which instrument driver is suitable for which programming language. The specifics of the different environments we discuss afterwards.

VXI plug&play drivers LabWindows/CVI drivers LabVIEW drivers IVI.NET drivers
Python X (bulky)
MATLAB X
C#, VB.NET X (if IVI.NET is not available) X
LabVIEW X
LabWindows/CVI X

For Python users in R&S Forum or Pycharm

Rohde & Schwarz does not provide native Python instrument drivers. The only way to use instrument drivers in Python is with its ctypes library and the VXI plug&play instrument drivers. For Python we recommend using the direct SCPI commands.

Find out more in the dedicated application note:

1MA196: Using R&S®Forum Application for Instrument Remote Control

For MATLAB users

Rohde & Schwarz provides MATLAB MDD drivers. Using MDD drivers requires advanced knowledge of VXI plug&play driver structure, you must manually import all enumeration constants from the driver header file. In addition, MATLAB Instrument Control Toolbox license is required. For MATLAB users we recommend using direct SCPI commands. This application note covers both approaches:

1MA171: How to use Rohde & Schwarz Instruments in MATLAB

For LabVIEW users

Rohde & Schwarz provides native LabVIEW drivers. Find out more in the application note:

1MA228: 10 Tips & Tricks on how to use Rohde & Schwarz LabVIEW Instrument drivers

For C#, VB.NET users

IVI.NET drivers are the clear choice. However, since the IVI.NET drivers are not yet available for all the Rohde & Schwarz instruments, you can also use the VXI plug&play drivers that come with the C# and VB.NET wrapper classes.

Find out more in the dedicated application note:

1MA268: How to use Rohde & Schwarz IVI.NET Instrument drivers

For LabWindows/CVI and other C/C++ environment users

VXI plug&play drivers are compiled CVI drivers for 32-bit and 64-bit Windows applications. You can use them both in C/C++ languages.

To use a CVI driver, add its entire source code into your project.

To use a VXI plug&play driver, add the driver's LLB file (for static linking) or its DLLs file (for dynamic linking) into your project.

リクエスト情報

ご質問や詳細な情報のご要望などがございましたら、こちらのフォームよりお気軽にお問い合わせください。担当者よりご連絡させていただきます。

マーケティング・パーミッション

次の手段によってローデ・シュワルツから情報を受信することを希望します。

詳細について

私は、このウェブサイトの出版物に記載されているRohde & Schwarz GmbH & Co. KGおよびRohde & Schwarzの法人および子会社が、
ここで選択した手段 (電子メールまたは郵便メール) を通じて、マーケティングおよび広告目的 (特別キャンペーンや値引きに関する情報など) で、私に連絡することに同意します。その内容は、電子計測、セキュリティ通信、モニタリングおよびネットワークテスト、放送およびメディア、そしてサイバーセキュリティ分野の製品やソリューションを含みますが、上記に限定されるものではありません。

お客様の権利

この同意表明は、件名が"Unsubscribe"の電子メールをnews@rohde-schwarz.com宛に送信することにより、いつでも取り消すことができます。これに加えて、今後の電子メール広告の購読を停止するためのリンクが、送信されるすべての電子メールに記載されています。個人データの使用と取り消し手順の詳細は、「プライバシーステートメント」に記載されています。

お問い合わせ内容が送信されました。 後ほどご連絡致します。
An error is occurred, please try it again later.