Bode plot oscilloscope software

General analysis

Bode plot oscilloscope software
Abrir Lightbox
Bode plot oscilloscope software
Abrir Lightbox
Bode plot oscilloscope software
Abrir Lightbox
Bode plot oscilloscope software, ScreenshotBode plot oscilloscope software, ScreenshotBode plot oscilloscope software, Screenshot

Key Facts

  • Bandwidth: 10 Hz to 25 MHz
  • Test modes: Fixed or custom amplitude profile
  • Up to 500 points per decade: Logarithmic gain and linear phase
  • Analysis: Waveform cursors and tabular view of test results

Oscilloscope software

The R&S®RTx-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio. The frequency response analysis option uses the oscilloscope’s built-in waveform generator to create stimulus signals ranging from 10 Hz to 25 MHz. Measuring the ratio of the stimulus signal and the output signal of the DUT at each test frequency, the oscilloscope plots gain and phase logarithmically.

Features & benefits

Amplitude profile

The R&S®RTx-K36 frequency response analysis (Bode plot) option allows users to profile the amplitude output level of the generator. This helps to suppress the noise behavior of the DUT when performing a control loop response or power supply rejection ratio and to improve signal-to-noise ratio (SNR). It is possible to define up to 16 steps.

Amplitude profile
Abrir Lightbox

Amplitude profile

The amplitude output level of the generator signal can be varied during the measurement to suppress the noise behavior of the DUT.

Improve resolution and markers support

You can choose the points per decade to set up and modify the resolution of your plot. The oscilloscope supports up to 500 points per decade. Markers can be dragged to the desired position, directly on the plotted trace. A legend displays the corresponding coordinates of the markers. To determine the crossover frequency, set one marker to 0 dB and the second marker to –180° phase shift. Now you can easily determine the phase and gain margin.

Vary points per decade
Abrir Lightbox

Vary points per decade

The measurement resolution can be varied by changing the points per decade

Measurement table

Furthermore, you can view the results in a table. The table of measurement results details information about each measured point, consisting of frequency, gain and phase shift. In case you use cursors, for ease of use, the associated row of the result table is highlighted. For reporting, screenshots, table results or both can be quickly saved to a USB device.

Measurement table
Abrir Lightbox

Measurement table

A table of measurement results provides detailed information about each measurement point, consisting of frequency, gain and phase shift

Broad probe portfolio

Accurate control loop response or power supply rejection ratio characterization highly depends on choosing the right probes, since peak-to-peak amplitudes of both Vin and Vout can be very low at some test frequencies. These values would be buried in the oscilloscope’s noise floor or in the switching noise of the DUT itself. We recommend the low-noise R&S®RT-ZP1X 38 MHz bandwidth 1:1 passive probes. These reduce measurement noise and provide the best SNR.

R&S®RT-ZP1X 38 MHz 1:1 passive probe
Abrir Lightbox

R&S®RT-ZP1X 38 MHz 1:1 passive probe

The low-noise passive probe reduces measurement noise and provides the best SNR.

Available models

Available models
Modelos
Amplitude profile
Markers support
Define max. phase
Min - meas. delay
Base unit
R&S®RTA-K36

R&S®RTA-K36

Order Number 1335.7975.02

Amplitude profile
Markers support
Define max. phase
Min - meas. delay
Base unit
R&S®RTB-K36

R&S®RTB-K36

Order Number 1335.8007.02

Amplitude profile
Markers support
Define max. phase
Min - meas. delay
Base unit
R&S®RTM-K36

R&S®RTM-K36

Order Number 1335.9178.02

Amplitude profile
Markers support
Define max. phase
Min - meas. delay
Base unit
R&S®MXO4-K36

R&S®MXO4-K36

Order Number 1335.5572.02

Amplitude profile
Markers support
Define max. phase
Min - meas. delay
Base unit

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted en breve.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Términos y condiciones:

La convocatoria es válida del 5 de Abril al 20 de junio de 2021. Participan transmisores de radio FM y TV de cualquier marca que se encuentren aún en operación. Se tomarán válidos para participar los datos registrados solo durante ese periodo de tiempo, solo se puede llenar el formulario 1 vez por persona. El acceso a ingresar datos en el formulario se restringirá el día 21 de Junio a las 00:00hrs. El 30 de Junio de 2021 anunciaremos a un ganador de cada categoría en este mismo web, por correo electrónico y a través de nuestras redes sociales. Más informacion. Anamaria@rohde-schwarz.com

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y el correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente éstas tienen facultad para recibir los premios. No está permitida la participación de una persona individual por nombre y cuenta propia, sino que deberá hacerlo como representante de una persona jurídica llenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo tendrá lugar en la sede de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de no aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de llenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán por cuenta del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.