R&S®R-Line Compact Test Chamber

Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Dieses Produkt ist abgekündigt
Weitere Informationen? Nehmen Sie Kontakt mit uns auf.
  • Übersicht

Kerndaten

  • Wide frequency range from 800 MHz to 18 GHz
  • Measurement of radiated spurious emissions (RSE), e.g. according to 3GPP TS 51.010 and ETSI 301 908-1 with R&S®EMC32 software

Kurzbeschreibung

The R&S®R-LINE Compact Test Chamber compact test chamber assists in eliminating emission problems and optimizing the RF performance of wireless terminals already in the initial phases of development.

Features Collapsed

  • Reduced time to market through early verification of radiated emissions
  • Efficient operation through measurements in the lab
  • Optimum utilization of resources through comprehensive, automated test sequences

Technische Daten

Environmental conditions
Operating temperature range +0°C to +35°C
Storage temperature range –10°C to +45°C

Unterstützte Technologien

  • Cellular Standards
  • Wireless Standards
  • Satellite Navigation

Kerndaten

  • Wide frequency range from 800 MHz to 18 GHz
  • Measurement of radiated spurious emissions (RSE), e.g. according to 3GPP TS 51.010 and ETSI 301 908-1 with R&S®EMC32 software
  • Measurement of the over-the-air (OTA) performance with R&S®AMS32 software
  • Measurement accuracy as high as in an anechoic chamber at significantly reduced investments in equipment and infrastructure
  • Compact size suitable for any R&D lab environment
  • Efficient through measurements with automated 3D positioner

Kurzbeschreibung

The R&S®R-LINE Compact Test Chamber compact test chamber assists in eliminating emission problems and optimizing the RF performance of wireless terminals already in the initial phases of development. This helps to avoid costly and time-consuming modifications to a large number of prototypes at a later stage, thus optimizing time to market and return on investment.

The R&S®R-Line compact RF chamber performs accurate radiated measurements with a high correlation compared to larger anechoic chambers.

Merkmale

  • Reduced time to market through early verification of radiated emissions
    • Measurement accuracy as high as in an anechoic chamber
    • Meets site VSWR (SVSWR) in line with CISPR 16-1-4:2007
    • Frequency range 800 MHz to 18 GHz
  • Efficient operation through measurements in the lab
    • Compact and versatile
    • Readily available verification tool
    • Significantly lower investment than for anechoic chamber
  • Optimum utilization of resources through comprehensive, automated test sequences

    Automated measurements using turnkey solutions that combine the R&S®R-Line with Rohde & Schwarz test systems

    • R&S®TS8991 Over The Air Performance (OTA) Test System
    • R&S®TS8996 Radiated Spurious Emissions (RSE) Test System

Technische Daten

General data
Environmental conditions
Operating temperature range   +0°C to +35°C
Storage temperature range   –10°C to +45°C
Relative humidity without condensation 90 % at +40 °C, non-condensing
Power supply 208 V to 230 V/50 Hz to 60 Hz max. 350 VA
Environmental test
Electromagnetic compatibility EU – EMC Directive 2004/108/EC in line with EN 61326-1, EN 55011 (class B),
EN 61000-3-2, EN 61000-3-3
Electrical safety EU – Low Voltage Directive 2006/95/EC in line with EN 61010-1
Mechanical data
Dimensions (W × H × D) including four movable and lockable castors 1700 mm × 2250 mm × 1640 mm
(66.93 in × 88.58 in × 64.57 in)
Weight   562 kg (1239 lb)
Door size (W × H)   500 mm × 1000 mm
19.68 in × 39.37 in
Size of EUT (∅ × H)   max. 330 mm × 240 mm
max. 12.99 in × 9.45 in
Weight of EUT   max. 1 kg (max. 2.2 lb)
Positioning speed of turntable   azimuth: 0.5 rpm to 10 rpm
elevation: 0.2 rpm to 10 rpm
Distance between test antenna and center of EUT    1.03 m (40.55 in)
Interfaces Data  
IEC/IEEE bus, RS-232-C alternatively for control of positioner in line with IEC 625-2 (IEEE 488.2)
Test antenna   2 × SMA (female)
Communications antenna   1 × N (female)
RF feedthroughs for calibration or connecting the EUT 2 × N (female)
2 × SMA (female)
RF specifications
Measurement range
Frequency range   800 MHz to 18 GHz
Polarization   horizontal and vertical, through ¸R&S®HL024A1 cross-polarized antenna
RF power   max. 3 W
Communications antenna   800 MHz to 6 GHz, circularly polarized
Field uniformity site VSWR, typ. 2 dB in line with CISPR 16-1-4:2007
Shielding effectiveness > 95 dB 800 MHz to 6 GHz
> 70 dB 6 GHz to 18 GHz

Unterstützte Technologien

  • Cellular Standards
    • WCDMA/HSPA/HSPA+
    • WCDMA-3GPP FDD
    • WCDMA-3GPP TDD
    • LTE
    • GSM/GPRS/EDGE/EDGE Evolution
    • CDMA2000® 1xEV-DO
    • CDMA2000® 1xRTT
    • TD-SCDMA
    • GSM-R
    • cdmaONE
    • IS-136
  • Wireless Standards
    • WiMAX IEEE 802.16e-2005 and IEEE 802.16-2004
    • WLAN IEEE 802.11 a/b/g
  • Satellite Navigation
    • Bluetooth® (Basic Rate)
    • GPS
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Informationen anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Angebot anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.
Geben Sie bitte Ihre Telefonnummer ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Demo anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Feedback
Teilen Sie uns Ihre Meinung mit
Teilen Sie uns bitte das entsprechende Thema mit.

Geben Sie bitte Ihre Anfrage ein.
Kontaktdaten

Geben Sie bitte Ihren Vornamen ein.

Geben Sie bitte eine gültige E-Mailadresse ein.

Geben Sie bitte Ihren Namen ein.
Security Response-Code
show captcha

Die Eingabe war nicht korrekt.
*Pflichtfeld
International Website