Key Facts
- Frequency ranges from 9 kHz up to 26.5 GHz
- Two or four ports
- Wide dynamic range of up to 150 dB
- Ultrafast sweep cycle times of 11.8 ms (1601 points, 1 MHz to 26.5 GHz)
- High output power: 11 dBm @ 26.5 GHz
Key Facts
Maximum throughput with ultrafast measurement cycles
With frequency ranges from 9 kHz to 4.5 GHz, 9 GHz, 20 GHz and 26.5 GHz, the R&S®ZNB3000 vector network analyzers are ideal for applications in the communications, aerospace and defense industries. High-volume production of RF components and short ramp-up times is the environment where the R&S®ZNB3000 shines and delivers maximum results. The R&S®ZNB3000 has a flexible upgrade concept to rapidly scale up and adapt to your requirements. The measurement speed, stability, outstanding RF performance and extended functions make the R&S®ZNB3000 the instrument to get the job done.
Quick Links
Maximum throughput with ultrafast measurement cycles
The combination of a fast DDS-based synthesizer, the best dynamic range in class and efficient backend data handling results in extremely high measurement throughput. The R&S®ZNB3020 can perform a frequency sweep from 1 MHz to 26.5 GHz, 1601 points, 500 kHz IF bandwidth with full two port error correction in a total measurement time of 21.2 ms. It is the instrument of choice for high volume production, where test per second costs low and throughput high are essential.
Front-end module test with the R&S®ZNB3000
Ideal for filter characterization
The measurement speed for filter tests is determined by the synthesizer settling times, the required dynamic range and the corresponding IF bandwidth. The R&S®ZNB3020 offers an innovative enhanced dynamic range mode that allows the use of higher IF bandwidths with same trace noise magnitude values as conventional VNAs, leading to improved measurement throughput.
R&S®ZNB3000 filter tests
Flexible frequency upgrade options
Additional frequency ranges and the easy frequency upgrade concept assure rapid scale-up of production and protect your investment for the long run. Regardless of the test requirements, die level, packaged or connectorized, the R&S®ZNB3000 is the preferred instrument of RF component manufacturers world-wide.
Designed to meet the toughest challenges
The R&S®ZNB3000 was designed with toughest testing challenges in mind and developed for high-volume production applications. It balances speed, stability and performance. The combination of high output power, +11 dBm at 26.5 GHz, innovative extended dynamic range mode, exceptionally low trace noise (typically 0.0008 dB RMS) and fast sweep times, makes it ideal for throughput, yield and accuracy.
Amplifier test with the R&S®ZNB3020
Measurements up to 48 ports
Components used in modern communications equipment support a growing number of frequency bands and additional functions. As a result, the number of RF ports on the modules is also growing. The R&S®ZNB3000 in combination with various switch matrices provides a comprehensive solution for complex measurements on modules with up to 48 ports. The matrices from Rohde & Schwarz support full crossbar measurements, allowing all S-parameters of a multiport DUT to be determined.
R&S®ZNB3020 & R&S®ZN-Z86 switch matrix 48 ports
Accelerating test automation
The R&S®ZNB3000 simplifies programming. The integrated SCPI recorder notes each keypress and creates a list of step-by-step commands even for the most complicated measurement setup. The recorded SCPI script can be directly copied into the user code or exported in C, Python and MATLAB.
SCPI recorder example
Fast and accurate characterization of active and passive RF components
The R&S®ZNB3000 is ideal for testing passive, active and frequency-converting components. A variety of hardware and software options are available for these measurements. Hardware options include two independent internal generators, a wide power sweep range and extended dynamic range in two or four port configurations. The software options include compression point vs frequency, noise figure measurements, intermodulation distortion measurements and intuitive measurement configuration. Time domain measurement options with eye diagrams and frequency-converting measurements are also available. A comprehensive list of embedding/deembedding options round off the vector network analyzer functions.
Delta-L calibration
The R&S®ZNB3000 test set and receivers feature excellent temperature and long-term stability. Magnitude and phase drift are very low, with typical values of less than 0.01 dB/°C and 0.15°/°C. A calibrated R&S®ZNB3000 allows precise measurements over several days without recalibration.
R&S®ZNB3004 with four ports.
Order Number 1351.5115.02
Bias tees for R&S®ZNB3004 base unit 2 port
Frequency range: 100 kHz to 4.5/9 GHz
Order Number 1351.5121.02
Bias tees for R&S®ZNB3004 base unit 4 port
Frequency range: 100 kHz to 4.5/9 GHz
Order Number 1351.5138.02
Second internal generator for R&S®ZNB3004 4 port
Requires R&S®ZNB3004 4 port model
Order Number 1351.5144.02
Second internal generator for R&S®ZNB3020 4 port
Requires R&S®ZNB3020 4 port model
Order Number 1316.1769.02
Precision oven quartz frequency reference (hardware opt.)
Order Number 1311.5995.04
GPIB interface
Order Number 1319.5088.02
Device control
Required for direct control of switch matrices
Order Number 1316.2459.05
Handler I/O
(Universal interface)
Order Number 1316.0004.02
DC Inputs
Order Number 1351.5821.02
Additional removable hard drive for the R&S®ZNB3000 with IPS15, WIN11 512 GB
Order Number 1351.5067.02
Frequency upgrade for R&S®ZNB3004 2 port
Increases frequency from 4.5 GHz to 9 GHz
Order Number 1351.5067.04
Frequency upgrade for R&S®ZNB3004 4 port
Increases frequency from 4.5 GHz to 9 GHz
Order Number 1351.5073.02
Frequency upgrade for R&S®ZNB3020 2 port
Increases frequency from 20 GHz to 26.5 GHz
Order Number 1351.5073.04
Frequency upgrade for R&S®ZNB3020 4 port
Increases frequency from 20 GHz to 26.5 GHz
Order Number 1351.5173.02
Extended power range down to -60 dBm,
for R&S®ZNB3004 2 port base unit
Order Number 1351.5180.02
Extended power range down to -60 dBm,
for R&S®ZNB3004 4 port base unit
Order Number 1351.5196.02
Extended power range down to -60 dBm,
for R&S®ZNB3020 2 port base unit
Order Number 1351.5209.02
Extended power range down to -60 dBm,
for R&S®ZNB3020 4 port base unit
Order Number 1351.5250.02
Receiver step attenuator, port 1 electronical, 30 dB, 10 dB steps for R&S®ZNB3004
Order Number 1351.5267.02
Receiver step attenuator, port 2 electronical, 30 dB, 10 dB steps for R&S®ZNB3004
Order Number 1351.5273.02
Receiver step attenuator, port 3 electronical, 30 dB, 10 dB steps for R&S®ZNB3004
Order Number 1351.5280.02
Receiver step attenuator, port 4 electronical, 30 dB, 10 dB steps for R&S®ZNB3004
Order Number 1351.5296.02
Extended dynamic range for R&S®ZNB3004 base unit 2 port
Order Number 1351.5309.02
Extended dynamic range for R&S®ZNB3004 base unit 4 port
Order Number 1351.5367.02
Time domain (TDR)
Order Number 1351.5373.02
Extended time domain analysis
Order Number 1351.5380.02
Distance-to-fault analysis
Order Number 1351.5396.02
Frequency converting measurements
Order Number 1351.5409.02
Intermodulation measurements
Order Number 1351.5421.02
10 MHz receiver bandwidth
Order Number 1355.8902.02
Gain compression measurements
Order Number 1351.5438.02
Frequency resolution 1 mHz
Order Number 1351.5444.02
Noise figure measurements
Order Number 1351.5450.02
Real-time measurement uncertainty analysis
Requires Swiss Metrology Institute METAS "VNA tools" software (free download from METAS website)
Order Number 1351.5467.02
Real-time measurement uncertainty analysis
Includes pre-installed Swiss Metrology Institute (METAS) "VNA tools" software
Order Number 1351.5480.02
EaZy deembedding (EZD)
Order Number 1351.5496.02
In-Situ de-embedding (ISD) that complies with IEEE 370
Order Number 1351.5515.02
Delta-L 4.0 PCB characterization
Order Number 1351.5509.02
Smart fixture de-embedding (SFD)
Order Number 1351.5521.02
HUMS software option
Health and utilization monitoring service for R&S®ZNB3000
Network analyzer calibration kits economy
Network analyzer calibration kits economy
Network analyzer calibration kits
Network analyzer calibration kits
Network analyzer verification kits
Waveguide calibration kits
Automatic calibration units
Network analyzer multiport calibration units
Network analyzer calibration units
Inline calibration units
Network analyzer calibration units
Order Number 1319.4500.02
Switch matrix, 8.5 GHz, 2 VNA ports to 6 test ports
Order Number 1319.4969.22
Additional test ports 7 to 12, 2 VNA ports to 12 test ports
The R&S®ZN-Z84 base unit is a prerequisite.
Order Number 1319.4969.32
Additional test ports 13 to 18, 2 VNA ports to 18 test ports
The R&S®ZN-Z84 base unit and R&S®ZN-Z84-B22 are prerequisites.
Order Number 1319.4969.42
Additional test ports 19 to 24, 2 VNA ports to 24 test ports
The R&S®ZN-Z84 base unit and the R&S®ZN-Z84-B32 are prerequisites.
Order Number 1319.4969.24
Additional test ports 7 to 12, 4 VNA ports to 12 test ports
The R&S®ZN-Z84 base unit is a prerequisite.
Order Number 1319.4969.34
Additional test ports 13 to 18, 4 VNA ports to 18 test ports
The R&S®ZN-Z84 base unit and R&S®ZN-Z84-B24 are prerequisites.
Order Number 1319.4969.44
Additional test ports 19 to 24, 4 VNA ports to 24 test ports
The R&S®ZN-Z84 base unit and the R&S®ZN-Z84-B34 are prerequisites.
Order Number 1351.2216.02
Switch matrix, 26.5 GHz, 2 VNA ports to 6 test ports
Order Number 1351.2900.22
Additional 7 to 12 test ports, 2 VNA ports to 12 test ports.
R&S®ZN-Z86 base unit is a prerequisite.
Order Number 1351.2900.32
Additional 13 to 18 test ports, 2 VNA ports to 18 test ports.
R&S®ZN-Z86 base unit and R&S®ZN-Z86-B22 are prerequisites.
Order Number 1351.2900.42
Additional 19 to 24 test ports, 2 VNA ports to 24 test ports.
The R&S®ZN-Z86 base unit and the R&S®ZN-Z86-B32 are prerequisites.
Order Number 1351.2900.24
Additional 7 to 12 test ports, 4 VNA ports to 12 test ports.
R&S®ZN-Z86 base unit is a prerequisite.
Order Number 1351.2900.34
Additional 13 to 18 test ports, 4 VNA ports to 18 test ports.
R&S®ZN-Z86 base unit and R&S®ZN-Z86-B24 base are prerequisites.
Order Number 1351.2900.44
Additional 19 to 24 test ports, 4 VNA ports to 24 test ports.
The R&S®ZN-Z86 base unit and the R&S®ZN-Z86-B34 are prerequisites.
Order Number 1328.8911.02
Semi-rigid cables 2.92 mm (f) -2.92 mm (m)
RF cable set for interconnection between the R&S®ZNB26/43 and R&S®ZN-Z86, benchtop operation.
Order Number 1351.2222.02
Switch matrix, 26.5 GHz, with additional RF access
Order Number 1351.2222.24
Extends 2 or 4 VNA ports to 12 test ports.
R&S®ZN-Z86X base unit is a prerequisite.
Order Number 1351.2222.44
Extends 2 or 4 VNA ports to 24 test ports.
R&S®ZN-Z86X base unit is a prerequisite.
Order Number 1328.8911.03
Semi-rigid cables 2.92 mm (f) -2.92 mm (m)
RF cable set for interconnection between the R&S®ZNB26/43 and the R&S®ZN-Z86X, benchtop operation.
Test cables ruggedized
Network analyzer test cables
Step attenuator
Order Number 1325.5905.02
External RFFE GPIO Interface (MIPI)
Includes one R&S®ZN-Z25 interface cable adapters
Order Number 1325.5905.03
External RFFE GPIO Interface (MIPI)
Including voltage and current measurements and includes one R&S®ZN-Z25 interface cable adapters
Applications of the R&S®ZNB3000
The R&S®ZNB3000 is engineered to meet the diverse needs of RF and microwave testing with exceptional speed, accuracy and adaptability. With its high throughput rate, it is especially suitable for high-volume production and short ramp-up time environments.
It has applications in:
Productos relacionados
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
Términos y condiciones:
La convocatoria es válida del 5 de Abril al 20 de junio de 2021. Participan transmisores de radio FM y TV de cualquier marca que se encuentren aún en operación. Se tomarán válidos para participar los datos registrados solo durante ese periodo de tiempo, solo se puede llenar el formulario 1 vez por persona. El acceso a ingresar datos en el formulario se restringirá el día 21 de Junio a las 00:00hrs. El 30 de Junio de 2021 anunciaremos a un ganador de cada categoría en este mismo web, por correo electrónico y a través de nuestras redes sociales. Más informacion. Anamaria@rohde-schwarz.com
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz
1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).
2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y el correo electrónico empresarial.
3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.
4. El sorteo está destinado únicamente a personas jurídicas, y solamente éstas tienen facultad para recibir los premios. No está permitida la participación de una persona individual por nombre y cuenta propia, sino que deberá hacerlo como representante de una persona jurídica llenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.
5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados entre el 1 de enero de 2020 y el 31 de diciembre de 2020:
Premio: 1 osciloscopio digital R&S®RTB2000
6. El sorteo tendrá lugar en la sede de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.
7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de no aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.
8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de llenar el formulario de participación.
9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán por cuenta del participante.
10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.
11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.
12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.
13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.