Key Facts
- Bandwidth: 200 MHz to 2 GHz
- Sample rate: 5 Gsample/s
- Max. memory depth: 200 Msample
- Vertical resolution: up to 16-bit
- MSO: 16 digital channels, optional, retrofittable
Key Facts
R&S®RTE1000 oscilloscopes offer a fully integrated multi-domain test solution with time, frequency, protocol and logic analysis functions. From embedded design development to power electronics analysis to general debugging, the R&S®RTE1000 handles everyday T&M challenges quickly, accurately and easily.
Quick Links
See signal details with up to 16-bit vertical resolution in HD mode.
In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.
You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.
The mixed signal option turns the R&S®RTE1000 oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.
Order Number 1326.2000.22
Order Number 1326.2000.24
Order Number 1326.2000.32
Order Number 1326.2000.34
Order Number 1326.2000.52
Order Number 1326.2000.54
Order Number 1326.2000.62
Order Number 1326.2000.64
Order Number 1326.2000.72
Order Number 1326.2000.74
Order Number 1326.2000.82
Order Number 1326.2000.84
Vertical system | ||
Analog channels | R&S®RTE1022/R&S®RTE1032/ R&S®RTE1052/R&S®RTE1102/ R&S®RTE1152/R&S®RTE1202 | 2 |
Analog channels | R&S®RTE1024/R&S®RTE1034/ R&S®RTE1054/R&S®RTE1104/ R&S®RTE1154/R&S®RTE1204 | 4 |
Digital channels (opt.) | 16 | |
Bandwidth (-3 dB) | R&S®RTE1022/R&S®RTE1024 R&S®RTE1032/R&S®RTE1034 R&S®RTE1052/R&S®RTE1054 R&S®RTE1102/R&S®RTE1104 R&S®RTE1152/R&S®RTE1154 R&S®RTE1202/R&S®RTE1204 | ≥ 200 MHz ≥ 350 MHz ≥ 500 MHz ≥ 1 GHz ≥ 1.5 GHz ≥ 2 GHz |
Rise time | R&S®RTE1022/R&S®RTE1024 R&S®RTE1032/R&S®RTE1034 R&S®RTE1052/R&S®RTE1054 R&S®RTE1102/R&S®RTE1104 R&S®RTE1152/R&S®RTE1154 R&S®RTE1202/R&S®RTE1204 | < 1.75 ns < 1 ns < 700 ps < 350 ps < 233 ps < 175 ps |
Input impedance | 50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF ± 1 pF (meas.) | |
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 500 μV/div to 1 V/div 1 MΩ: 500 μV/div to 10 V/div |
ADC resolution | 8 bit | |
System ENOB | 7 bit | |
Acquisition system | ||
Realtime sampling rate | max. 5 Gsample/s on each channel | |
Acquisition memory | standard configuration, per channel/1 channel active | R&S®RTE1000 2-channel model: 10/20 Msample R&S®RTE1000 4-channel model: 10/40 Msample |
max. upgrade (R&S®RTE-B102 option), per channel/1 channel active | R&S®RTE1000 2-channel model: 50/100 Msample R&S®RTE1000 4-channel model: 50/200 Msample | |
Max. acquisition rate | > 1 000 000 waveforms/s | |
Decimation modes | any combination of decimation mode and waveform arithmetics | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Horizontal system | ||
Timebase range | 50 ps/div to 5000 s/div | |
Accuracy (after delivery/calibration) | ±2 ppm | |
Channel deskew | ±100 ns | |
Trigger system | ||
Standard Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video | |
Optional Trigger types | serial bus trigger | |
Trigger sensitivity | definition of trigger hysteresis | can be set automatically or manually from 0 div to 5 div |
Analysis and measurement functions | ||
Automatic measurements | 77 measurement functions | |
Cursor measurements | 2 cursor sets, each consisting of two horizontal and two vertical cursors | |
Waveform mathematics | 4 math waveforms; mathematics, logical operations, comparison, FIR filter, FFT | |
Mask testing | ||
Mask definition | advanced (user-configurable, hardware based) | |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO Memory depth | 100 Mpts per channel | |
MSO Bandwidth | 400 MHz | |
MSO Sampling rate | 5 Gsample/s per channel | |
MSO Input impedance | 100 k || 4 pF | |
Parallel buses | up to 4 | |
General data | ||
Dimensions | W x H x D | 427 mm × 249 mm × 204 mm (16.81 in × 9.8 in × 8.03 in) |
Weight | without options, nominal | 8,6 kg (18.96 lb) |
Display | 10.4" LC TFT color touchscreen, 1024 × 728 pixel (XGA) | |
Interfaces | 1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output | |
Operating system | Windows |
Order Number 1326.3570.02
Mixed Signal Option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample per channel
Adds 16 digital channels to R&S®RTE1000 oscilloscopes.
Order Number 1333.0750.02
Digital Extension Port for R&S®RTE
Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTE-B1
Order Number 1326.3012.02
Arbitrary waveform generator
Add 2-channel 500 Msample/s waveform generator and 8-channel pattern generator
Order Number 1317.4978.02
GPIB Interface
Order Number 1317.7002.02
Replacement SSD, incl. firmware
SSD comes pre-installed with operating system and scope application
Order Number 1326.1155.02
Memory upgrade to 20 Msample
Memory upgrade to 20 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
Order Number 1326.1161.02
Memory upgrade to 50 Msample
Memory upgrade to 50 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
Order Number 1326.1384.02
Bandwidth upgrade of the R&S®RTE1022/4 to 350 MHz bandwidth, incl. calibration
Order Number 1326.1390.02
Bandwidth upgrade of the R&S®RTE1022/4 to 500 MHz bandwidth, incl. calibration
Order Number 1326.1403.02
Bandwidth upgrade of the R&S®RTE1022/4 to 1 GHz bandwidth, incl. calibration
Order Number 1326.1410.02
Bandwidth upgrade of the R&S®RTE1022/4 to 1.5 GHz bandwidth, incl. calibration
Order Number 1326.1426.02
Bandwidth upgrade of the R&S®RTE1022/4 to 2 GHz bandwidth, incl. calibration
Order Number 1326.1432.02
Bandwidth upgrade of the R&S®RTE1032/4 to 500 MHz bandwidth, incl. calibration
Order Number 1326.1449.02
Bandwidth upgrade of the R&S®RTE1032/4 to 1 GHz bandwidth, incl. calibration
Order Number 1326.1455.02
Bandwidth upgrade of the R&S®RTE1032/4 to 1.5 GHz bandwidth, incl. calibration
Order Number 1326.1461.02
Bandwidth upgrade of the R&S®RTE1032/4 to 2 GHz bandwidth, incl. calibration
Order Number 1326.1478.02
Bandwidth upgrade of the R&S®RTE1052/4 to 1 GHz bandwidth, incl. calibration
Order Number 1326.1484.02
Bandwidth upgrade of the R&S®RTE1052/4 to 1.5 GHz bandwidth, incl. calibration
Order Number 1326.1490.02
Bandwidth upgrade of the R&S®RTE1052/4 to 2 GHz bandwidth, incl. calibration
Order Number 1326.1503.02
Bandwidth upgrade of the R&S®RTE1102/4 to 1.5 GHz bandwidth, incl. calibration
Order Number 1326.1510.02
Bandwidth upgrade of the R&S®RTE1102/4 to 2 GHz bandwidth, incl. calibration
Order Number 1326.1526.02
Bandwidth upgrade of the R&S®RTE1152/4 to 2 GHz bandwidth, incl. calibration
Order Number 1326.1178.02
I²C/SPI triggering and decoding
Order Number 1326.1184.02
UART/RS-232 triggering and decoding
Order Number 1326.1190.02
CAN/LIN triggering and decoding
Order Number 1326.1203.02
FlexRay™ triggering and decoding
Order Number 1326.1210.02
I²S/LJ/RJ/TDM triggering and decoding
Order Number 1326.1226.02
MIL-1553 triggering and decoding
Order Number 1326.1232.02
ARINC 429 triggering and decoding
Order Number 1326.1332.02
Ethernet serial decoding
Order Number 1326.1249.02
CAN-FD triggering and decoding
Order Number 1326.1603.02
SENT triggering and decoding
Order Number 1801.2852.02
Bus analysis
Order Number 1326.1326.02
MANCHESTER/NRZ triggering and decoding
Order Number 1326.1255.02
MDIO triggering and decoding
Order Number 1333.0615.02
100BASE-T1 triggering and decoding
Order Number 1326.1610.02
USB 1.0/1.1/2.0/HSIC triggering and decoding
Order Number 1326.3158.02
USB-PD triggering and decoding
Order Number 1326.2845.02
SpaceWire triggering and decoding
Order Number 1326.3193.02
CXPI triggering and decoding
Order Number 1326.1261.02
High definition mode
Order Number 1326.3006.02
Spectrum analysis
Order Number 1326.1278.02
Power analysis
Order Number 1802.9296.02
Upgrade to Windows 10 (includes new PC and Windows 10 license)
Order Number 1802.9338.02
Upgrade to Windows 10 (includes new PC, new SSD and Windows 10 license)
Order Number 1333.0096.02
Front Cover
Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope
Order Number 1304.9118.02
Soft Case
Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories
Order Number 1317.7025.02
Transit case
Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport
Order Number 1317.7031.02
Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes
Order Number 1304.8286.00
19" Rackmount Adapter
For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 19" rack with 6U heigth
Order Number 1338.0007.02
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Order Number 1409.7550.00
Passive probe, 500 MHz, 10:1
Order Number 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Order Number 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Order Number 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Order Number 1410.4309.02
Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Order Number 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Order Number 1410.4609.02
Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface
Order Number 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Order Number 1800.4700.02
Modular probe amplifier module, 1.5 GHz
Order Number 1419.3005.02
Modular probe amplifier module, 3 GHz
Order Number 1419.4301.02
Solder-in probe tip cable for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Order Number 1801.4349.02
Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system
>16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Order Number 1419.4318.02
Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Order Number 1419.4324.02
Square-pin probe tip module for R&S®RT-ZM modular probe system
> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM
Order Number 1419.4224.02
Quick connect probe tip module for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
Order Number 1419.4353.02
Browser module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, DM
Order Number 1419.4201.02
SMA module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
Order Number 1419.4218.02
Temperature kit for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
Order Number 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Order Number 1326.0259.02
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs
Order Number 1326.0259.04
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs
Order Number 1333.0873.02
250 MHz passive high voltage probe
Order Number 1409.7720.02
400 MHz passive high voltage probe
Order Number 1409.7737.02
400 MHz passive high voltage probe
Order Number 1422.0703.02
100 MHZ high voltage differential probe
Order Number 1333.0821.02
Active differential probe, 200 MHz, BNC interface
Order Number 1333.0838.02
Active differential probe, 800 GHz, BNC interface
Order Number 1800.2107.02
100 MHz High voltage differential probe
Order Number 1800.2207.02
200 MHz High voltage differential probe
Order Number 1800.2007.02
100 MHz High voltage differential probe
Order Number 1337.9700.02
25 MHz High voltage differential probe
Order Number 1337.9800.02
25 MHz High voltage differential probe
Order Number 1333.0850.02
AC/DC 20 kHz current probe
Order Number 1333.0844.02
100 kHz current probe
Order Number 1409.8204.02
2 MHZ current probe
Order Number 1409.7750K02
10 MHZ current probe
Order Number 1409.8210.02
10 MHZ Current probe
Order Number 1409.8227.02
50 MHZ Current probe
Order Number 1409.7766K02
100 MHZ current probe
Order Number 1409.8233.02
100 MHZ current probe
Order Number 1409.7772K02
120 MHz current probe
Order Number 1801.4932.02
120 MHz current probe
Order Number 1147.2736.02
E and H near-field probe set
Order Number 1326.4190.02
Trigger and decode bundle option
Decode more than 28 serial protocols with the R&S®RTE trigger and decode software bundle. T&D bundle includes I2C/SPI, UART/RS232, CAN/LIN, FlexRay, I2S, MIL, ARINC, Ethernet, CAN-FD, SENT, Custom, MDIO, USB2.0, USB-PD, SpaceWire, CXPI
Productos relacionados
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
Términos y condiciones:
La convocatoria es válida del 5 de Abril al 20 de junio de 2021. Participan transmisores de radio FM y TV de cualquier marca que se encuentren aún en operación. Se tomarán válidos para participar los datos registrados solo durante ese periodo de tiempo, solo se puede llenar el formulario 1 vez por persona. El acceso a ingresar datos en el formulario se restringirá el día 21 de Junio a las 00:00hrs. El 30 de Junio de 2021 anunciaremos a un ganador de cada categoría en este mismo web, por correo electrónico y a través de nuestras redes sociales. Más informacion. Anamaria@rohde-schwarz.com
Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz
1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).
2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y el correo electrónico empresarial.
3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.
4. El sorteo está destinado únicamente a personas jurídicas, y solamente éstas tienen facultad para recibir los premios. No está permitida la participación de una persona individual por nombre y cuenta propia, sino que deberá hacerlo como representante de una persona jurídica llenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.
5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados entre el 1 de enero de 2020 y el 31 de diciembre de 2020:
Premio: 1 osciloscopio digital R&S®RTB2000
6. El sorteo tendrá lugar en la sede de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.
7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de no aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.
8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de llenar el formulario de participación.
9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán por cuenta del participante.
10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.
11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.
12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.
13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.