Messung des Wirkungsgrads eingebetteter Leistungswandler

Leistungsumwandlung

Messung des Wirkungsgrads

Solutions for embedded power efficiency testing

Power designers face the challenge of increasing efficiency and performance requirements while meeting reliability standards, achieving higher power density and reducing cost. One approach to increasing efficiency gains is through faster switching with lower losses. However, higher dV/dt can result in higher switching losses, make it more difficult to control the gate drive, produce higher ripple current and increase EMI. Making accurate switching measurements with an oscilloscope and oscilloscope probe is challenging due to the need for higher resolution and issues related to increased common mode error at higher frequencies. Accurate measurements can be an even greater challenge for designers working with wide bandgap materials. Rohde & Schwarz oscilloscopes, power probes and software enable power designers to optimize their designs.

Measuring power efficiency on wide bandgap devices

Power designers migrating from silicon to wide bandgap

Many power designers are moving to wide bandgap (WBG) materials such as SiC and GaN to increase efficiency through faster switching. A WBG semiconductor's fast switching capability must be well characterized in order to optimize efficiency gains, reduce losses and avoid shoot through. A high-resolution, low-noise Rohde & Schwarz oscilloscope combined with a Rohde & Schwarz high voltage differential probe with superior common mode rejection across frequency allows designers to:

  • Match simulation results to measured results
  • Clearly observe ringing and overshoot/undershoot under varying load conditions
  • Verify rise/fall time from hundreds of ps to 10s of ns
  • Characterize the dead time
  • Visualize the Miller region
High-resolution oscilloscopes and superior high voltage differential probes

Embedded power measurement equipment

Power designs are moving toward higher voltages with faster edge rates. Making power efficiency measurements requires a high-resolution oscilloscope and high voltage differential probes with top performance, large differential and common mode range, and high common mode rejection across the bandwidth.

Typischer Messaufbau mit dem R&S®HMC8015 Leistungsanalysator und dem R&S®HZC815 Steckdosenadapter
Typischer Messaufbau mit dem R&S®HMC8015 Leistungsanalysator und dem R&S®HZC815 Steckdosenadapter

Messung von Standby-Leistungsaufnahmen

Vollautomatische Messung der Leistungsaufnahme im Standby-Modus gemäß IEC 62301 und EN 50564 mit dem R&S®HMC8015 Leistungsanalysator. Der Setup-Wizard führt den Anwender Schritt für Schritt durch die Messung und stellt die erforderlichen Geräteparameter ein.

Related products

R&S®RTM3000 / RTA4000

See more of your signal with the power of 10. With up to 1 GHz bandwidth, these oscilloscopes offer 10-bit vertical resolution and ultra deep memory for longer acquisitions at full bandwidth.

Product information

R&S®RTE1000/RTO2000

These fully integrated multi-domain oscilloscopes are excellent tools for analyzing switching behavior and debugging EMI issues. These scope series have up to 6 GHz bandwidth, 16-bit vertical resolution and up to 2 Gsample maximum memory depth.

Product information

R&S®RT-ZHD high voltage differential probes

Designed in-house with superior performance, large differential and common mode range and superior common mode rejection across the bandwidth.

Product information

R&S®HMC8015 Power analyzer

The R&S®HMC8015 Power analyzer is a compact tester for AC/DC load and standby current characterization that enables measurements without additional tools such as a computer or remote infrastructure. In addition to a numerical and graphical display with 26 key parameters, the instrument delivers performance and compliance protocols in line with IEC 62301, EN 50564 and EN 61000-3-2.

Product information

Verwandte Themen

EMV-Fehlersuche

Mehr Informationen

Regelkreisanalyse

Mehr Informationen

Schaltanalyse

Mehr Informationen

Informationen anfordern

Haben Sie Fragen oder benötigen Sie weitere Informationen? Nutzen Sie hierzu einfach unser Kontaktformular und wir setzen uns umgehend mit Ihnen in Verbindung.

Ich möchte Informationen von Rohde & Schwarz erhalten per

Marketing-Einverständniserklärung

Was bedeutet das im Einzelnen?

Ich bin damit einverstanden, dass die ROHDE & SCHWARZ GmbH & Co. KG und die im Impressum dieser Website genannte, ROHDE & SCHWARZ zugehörige Gesellschaft oder Niederlassung, mich über den gewählten Kommunikationskanal (E-Mail oder Post) zu Marketing- und Werbezwecken kontaktiert (z.B. zur Übersendung von Informationen über Sonderangebote und Rabattaktionen), die in Zusammenhang mit Produkten und Lösungen aus den Bereichen Messtechnik, sichere Kommunikation, Monitoring and Network Testing, Rundfunk- und Medientechnik sowie Cybersicherheit stehen, aber nicht auf diese beschränkt sind.

Ihre Rechte

Diese Einverständniserklärung kann jederzeit durch Senden einer E-Mail, in deren Betreffzeile "Unsubscribe" steht, an news@rohde-schwarz.com, widerrufen werden. Darüber hinaus enthält jede von uns versandte E-Mail einen Link, durch den das Abbestellen zukünftiger Werbung per E-Mail möglich ist. Weitere Einzelheiten zur Verarbeitung personenbezogener Daten und zum Widerrufsverfahren finden sich in unserer Datenschutzerklärung..