R&S®IMS Integrated Measurement System

Off-the-shelf EMC - the one-box solution up to 3 GHz

Dieses Produkt ist abgekündigt
Beachten Sie das(die) folgende(n) Nachfolgeprodukt(e):

Kerndaten

  • Signal source
  • Signal switching
  • Power measurement

Features

  • Components
  • Signal generation
  • Power measurement

Kerndaten

  • Compact

    The Integrated Measurement System R&S IMS offers everything needed in a modern EMS test system:

    • Signal source
    • Signal switching
    • Power measurement
    • Control and switching for up to three amplifiers, including interlock
    • R&S® IMS operating system: fully compliant test software for EMS and EMI measurements
    • Integrated amplifier
    • Spectrum analyzer
  • Wide range of applications

    A compact instrument for EMS measurements for:

    • Commercial standards
    • Military standards
    • Automotive standards
    • Measurements supporting development
    • Certification measurements
  • Efficient and flexible
    • Easy test setup – only a few additional components required
    • Compact design – low space requirements – easy installation
    • Plug & play – connect controller via USB interface and start measurements
    • Cost-efficient, fully automatic measurements
    • Further extensions possible
  • Successor products

    Successor products to the R&S®IMS are: EMC32-S and softwareoptions, OSP with suitable switch modules and SMB100A

Merkmale

  • Components

    The Integrated Measurement System R&S® IMS is a complete EMS test system for compliance tests in accordance with commercial, military and automotive standards from 9 kHz to 3 GHz.

  • Signal generation

    The analog modulation types AM, FM, φM and PM are available. The optional Generator Interlock Relay R&S® IMS-B3 makes it possible to insert a 50 Ω termination rather than the generator signal if an interlock loop is open.

  • Power measurement

    The Power Sensor R&S® NRP-Z91 is used to measure forward and reflected power and to monitor, for example, injected current in the case of bulk current injection (BCI). A fast, wear-free PIN diode switch allows switching between forward power, reflected power and monitoring. It is also used for system calibration. Additional power sensors can also be implemented (option R&S® IMS-B7 required).

  • Spectrum analyzer module

    If the optional Spectrum Analyzer Module R&S® IMS-B1 is added, frequencyselective power measurements can be performed. This makes it possible, for example, to take harmonic components of the amplifier into account at the 1 dB compression point. Another application is current monitoring with the BCI method in the automotive range (checking of the first five harmonics).

  • RF switching unit

    The RF switching unit handles the switching of all R&S® IMS RF paths for up to three amplifiers. Two amplifier outputs can be switched to two different transducers (e.g. antennas, current probes) or connection points (e.g. in anechoic chambers and shielded enclosures) by means of the optional Transfer Relay R&S® IMS-B2.

  • Internal amplifier module

    Conducted measurements can be performed using an internal amplifier module (R&S® IMS model 14), which has a frequency range of 9 kHz to 250 MHz. The minimum amplifier power of 25 W (CW lin) permits measurements with coupling/decoupling networks (CDN) at a test voltage of 10 V in accordance with EN 61000-4-6.

  • External amplifiers

    Amplifiers with an authorized USB control (e.g. from BONN Elektronik GmbH) can be integrated into the system via plug & play. Up to three amplifiers can be controlled and connected.

  • Interlock

    The R&S® IMS operating system supports the control of an interlock loop for monitoring security functions during the EMS measurement, e.g. door contacts and amplifier status.

  • EUT monitoring

    To allow EUT monitoring during the EMC test, the R&S® IMS has four digital inputs. These inputs can be queried either individually or together. To allow EUT stimulation, the R&S® IMS provides four digital outputs (static values or pulse signals).

  • IMS operating system
  • Complete EMC package

    The R&S® IMS operating system supports measurements for determining conducted and radiated susceptibility and emission on terminal equipment, modules and integrated circuits. A complete EMS test system is obtained by adding just a few extra components. The intuitive graphical user interface makes learning and operating the system easy. The measurement philosophy is designed for compliance and batch tests with high EUT throughput as well as for interactive tests supporting development. Applications range from development and conformance tests to production and quality assurance.

  • Electromagnetic susceptibility – EMS

    The factory-ready test sequences can be adapted to lab instruments either interactively or via the con. guration wizard. The online help provides step-by-step instructions for all tasks from configuring the setup to performing measurements. During susceptibility tests, integrated control mechanisms limit the susceptibility level to protect both the EUT and the test system from being overloaded.

  • EMS measurement features for automotive applications

    The following list contains various measurement functions for generating interference that are implemented specifically for the automotive industry:

    • The test specifications for conducted susceptibility (BCI) call for the measurement of amplifier harmonics and the limiting of the current susceptibility level. To make this possible, the R&S® IMS operating system offers a function for monitoring harmonics via a spectrum analyzer or test receiver. This function can also be used to check an amplifier
    • Parallel measurement of the forward and reflected power and the susceptibility level helps boost measurement speed and EUT throughput
    • To ensure the reproducibility of test results, the R&S® IMS operating system supports the TEM cell attenuation measurement required in ISO 11452-3
    • User-defined equations make it possible to calculate additional single quantities from the current measured values, for example the system impedance of a BCI test setup
  • EUT monitoring and stimulation

    In addition to generating interference, the EMS measurement software is responsible for monitoring, where the two main tasks are stimulation and monitoring of the EUT. The following integrated stimulus functions make it possible to control the EUT at defined points in the test sequence:

    • Changing the EUT to a defined state (e.g. switching it on or off) when a measurement is started or stopped
    • Triggering an action of the EUT at specific frequencies or at each test frequency and using the monitoring functions to check the EUT's response to the effects of the interference
    • Resetting the EUT to a defined state after a faulty EUT response has been detected

    The monitoring functions of the R&S® IMS operating system permit fully automatic monitoring of the EUT. The objective is to obtain a GO or NOGO (PASS / FAIL) result for the test frequency and the test level. Monitoring channels can be defined for this purpose. A GO / NOGO decision is reached by using a definable threshold or a decision window. The measured values are displayed in a result table or in a graph. In addition, a separate table is generated that contains only the NOGO frequencies.

    Physical quantities (voltage, current, frequency, temperature) can be monitored either acoustically (sound level) or visually (camera). In the case of tests in the automotive range, vehicular bus systems (CAN, LIN, MOST, FlexRay) can also be monitored.

  • Monitoring with measuring instruments

    If communication is via physical quantities, measuring instruments (oscilloscope, TTL converter or voltmeter) are used to monitor the EUT's output signals or inject a defined signal at its inputs. USB, RS-232-C, TTL inputs and outputs and software interfaces are possible.

  • Automatic determination of immunity thresholds

    It is important – particularly in development – to determine maximum susceptibility versus frequency. This fully automatic susceptibility measurement yields two susceptibility level characteristics (hysteresis) that show the susceptibility level at which the faulty EUT response disappears and then reappears. The extensive monitoring capabilities of the R&S IMS operating system allow this measurement task to be automated.

  • Functional expansions

    The option concept of the IMS OS allows functional expansions for specific customer requirements. By using the options of the R&S EMC32-S EMC measurement software, it is possible to perform measurements in reverberation chambers or measurements in line with mobile radio standards, for example. Automatic EMS test sequences are an important expansion option and allow further automation and thus a more efficient use of the test chambers. An automatically controlled EUT test can be performed using several parameters (loops) (sequential test, e.g. several types of modulation, several turntable positions or several polarizations).

Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Angebot anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.
Geben Sie bitte Ihre Telefonnummer ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Do not enter data in this field
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Demo anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Do not enter data in this field
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Informationen anfordern

Geben Sie bitte Ihre Anfrage ein.
Geben Sie bitte Ihren Vornamen ein.
Geben Sie bitte Ihren Namen ein.
Geben Sie bitte eine gültige E-Mailadresse ein.
Geben Sie bitte Ihren Firmennamen ein.
Geben Sie bitte Ihre Stadt ein.
Geben Sie bitte Ihre Postleitzahl ein.

Wählen Sie bitte Ihr Land aus.
Geben Sie bitte die im Bild dargestellten Zeichen ein
show captcha
Die Eingabe war nicht korrekt.
Do not enter data in this field
Vielen Dank!

Ihre Anfrage wurde erfolgreich versendet!

Wir nehmen in Kürze Kontakt mit Ihnen auf.

Ihr Rohde & Schwarz -Team

Feedback
Teilen Sie uns Ihre Meinung mit
Teilen Sie uns bitte das entsprechende Thema mit.

Geben Sie bitte Ihre Anfrage ein.
Kontaktdaten

Geben Sie bitte Ihren Vornamen ein.

Geben Sie bitte eine gültige E-Mailadresse ein.

Geben Sie bitte Ihren Namen ein.
Security Response-Code
show captcha

Die Eingabe war nicht korrekt.
Do not enter data in this field
*Pflichtfeld
International Website